LECTRON Energy Meter 100 Amp Power Consumption Meter

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-PRODUCT

About the Lectron Energy Meter

The Lectron Energy Meter allows you to measure how much electricity is used by your Lectron
V-BOX Charging Station.

In the BoxLECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 1

Warnings

  1. During normal operation, hazardous voltages may be present in some of the terminals of this unit. Always use with caution.
  2. Ensure all parts are de-energized before attempting to connect.
  3. Never touch or adjust terminals after installation.
  4. Only install in a dry and safe environment.

Disclaimer

  1. Installation should only be done by a qualified professional, following all local regulations.
  2. This energy meter should never be used as the sole means of fault protection.
  3. Install this energy meter after your main power supply.
  4. Only use this energy meter with the Lectron
    V- BOX charging station.

LCD DisplayLECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 2

  1. energy measurement value
  2. total value
  3. import / export energy
  4. maximum demand (loading current)
  5. PF (power factor); Hz (frequency)
  6. measurement of kVArh (reactive power)
    measurement of kWh (active power)
  7. power level
  8. time/duration
  9. lock device

How to Install

Install the energy meter by connecting it between your electrical panel and your V-BOX.LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 3

  1. Connect the ground wire from the electrical panel to the V-BOX.LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 4
  2. Insert the neutral wire from the electrical panel into the no. 1 port at the top of the energy meter. Flip open the top compartment and tighten the screw using a Phillips screwdriver (not included).LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 5
  3. Insert the neutral wire from the V-BOX into the no. 4 port at the bottom of the energy meter. Flip open the bottom compartment and tighten the screw.LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 6
  4. Insert the live wire from the electrical panel into the no. 2 port at the top of the energy meter. Tighten the screw and close the compartment.LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 6
  5. Insert the live wire from the V-BOX into the no. 3 port at the bottom of the energy meter. Tighten the screw and close the compartment.LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 8

Scrolling Between Functions

Click the scroll button to go through the functions, and press the enter button to select the function.
Buttons:LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 9

Note: When the energy meter is powered on, it will initiate a self check. After that, it will display the total kWh (active power).

  1. total kWh
  2. import kWh
  3. export kWh
  4. resettable kWh
  5. total kVArh
  6. import kVArh
  7. export kVArh
  8. resettable kVArh
  9. max power demand
  10. voltage
  11. current
  12. W (watt)
    * speed of data exchange
  13. VAr (volts-amps reactive)
  14. VA (volt-ampere)
  15. power factor
  16. frequency
  17. DI 1 (digital input)
  18. DI 2
  19. modbus ID
  20. baud rate*
  21. continuous running time
Order Display

(example)

Function / Description
 

 

1

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 10  

 

total active energy

 

 

2

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 11  

 

import active energy

 

 

3

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 12  

 

export active energy

 

 

4

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 13  

 

total resettable energy

 

 

5

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 14  

 

total reactive energy

 

 

6

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 15  

 

import reactive energy

 

 

7

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 17  

 

export reactive energy

 

 

8

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 18  

total resettable reactive energy

 

 

9

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 19  

total max. power demand

 

 

10

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 20  

 

voltage

 

 

11

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 21  

 

current

 

 

12

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 22  

 

active power

 

 

13

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 23  

 

reactive power

 

 

14

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 24  

 

apparent power

 

 

15

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 25  

 

power factor

 

 

16

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 26  

 

frequency

 

 

17

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 27  

 

DI 1 -counting

 

 

18

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 28  

 

DI 2 -counting

 

 

19

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 29  

 

modbus address

 

 

20

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 30  

 

baud rate

 

 

21

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 31  

continuous running time (in total)

Setup Mode

To go into setup mode and adjust the settings of your energy meter, press and hold the “enter” button for 3 seconds.

Order Display

(example)

Value / Description
 

 

 

1

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 32

 

 

Password

You will first be asked to enter a password.

 

The Default password is: 1000

 

 

2

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 33  

Address ID Default ID is 001 Range: 001 – 247

 

 

 

 

 

 

2.1

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 34

 

 

 

 

 

Press the “enter” button and the red digit will flash.

 

Press the “scroll” button to change the value.

Then, press and hold the “enter” button to confirm.

 

 

 

3

 

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 35

 

Baud rate

Default value: 2400bps Range: 1200, 2400,

4800, 9600,

19200 bps.

 

 

 

 

 

3.1

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 36

 

 

 

Press the “enter” button and the red digit will flash.

 

Press the “scroll” button to change the value.

Then, press and hold the “enter” button to confirm.

 

 

4

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 37 Parity

Default: None Option:None, Even,

Odd

 

 

 

 

4.1

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 38

 

 

 

Press the “enter” button and the red digit will flash.

 

Press the “scroll” button to change the parity option. Then, press and hold the “enter” button to confirm.

 

 

 

5

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 39

 

 

Demand Integration Time*

Default: 15 minutes Option: OFF / 5 / 10 /

15 / 30 / 60 min

 

*energy consumption period

 

 

 

 

 

5.1

 

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 40

 

 

Press the “enter” button and the red digit will flash.

 

Press the “scroll” button to change the DIT option. Then, press and hold the “enter” button to confirm.

 

 

6

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 41  

Automatic Scroll Time Interval

Default: 0 seconds

Option: 0 – 30 sec

 

 

 

 

 

6.1

 

 

 

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 42

 

Press the “enter” button and the red digit will flash.

 

Press the “scroll” button to change the time interval option. Then, press and hold the “enter” button to confirm.

 

 

 

 

7

 

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 43

Backlight duration: Default: 60 minutes Option: OFF / 5 / 10 /

20 / 30 / 60 min

 

Press and hold the “enter” button to adjust backlight duration.

 

 

7.1

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 44 Press the “scroll” butto to change the backlight duration. Then, press and hold the “enter” button to confirm.
 

 

8

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 45  

Clear

Press and hold the “enter” button to clear the interface.

 

 

8.1

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 46  

To clear the max demand of active power, press and hold the “enter” button.

 

 

 

8.2

 

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 47

 

To clear the resettable energy, press the “scroll” button to go into the energy reset page. Then, press and hold the “enter” button to confirm.

 

 

9

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 48  

Password

Default: 1000

 

 

 

 

 

9.1

 

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 49

 

 

Resetting the Password Press the “enter” button and the red digit will flash.

 

Press the “scroll” button to change the value.

After selecting a new password, press and hold the “enter” button to confirm.

 

 

10

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 50  

DI- filtering time

Default: 100 mS

 

 

 

 

 

10.1

 

 

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 51

Press the “enter” button and the red digit will flash.

 

Press the “scroll” button to change the value.

After selecting a new filtering time, press and hold the “enter” button to confirm.

Specifications

  • Voltage: 100 – 240 V AC
  • Frequency: 50 / 60 Hz (±10%)
  • Base current: 10 A
  • Maximum current: 100 A
  • Display: LCD with white backlight
  • Maximum reading: 999999.9 kWh / kVArh
  • Power consumption: <2W / 10VA
  • Operating temp: -13 ºF to 158 ºF
  • Weatherproof rating: IP51 (indoor)
  • Dimensions: 14.2 x 39 x 25 in
  • Certification: UL94

Get More Support

Scan the QR code below or email us at: contact@ev-lectron.com

LECTRON-Energy-Meter-100-Amp-Power-Consumption-Meter-FIG 52

www.ev-lectron.com

Documents / Resources

LECTRON Energy Meter 100 Amp Power Consumption Meter [pdf] User Manual
Energy Meter 100 Amp Power Consumption Meter, Energy Meter, 100 Amp Power Consumption Meter, Consumption Meter, Meter