LEAP SENSORS 53-100187-24 Leap Wireless Sensor System
Copyright and Trademarks
No part of this product or related documentation shall be reproduced in any form by any means without prior written authorization of Phase IV Engineering, Incorporated. No part of this document shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from Phase IV Engineering, Incorporated.
Although every precaution has been taken in the preparation of this document, Phase IV Engineering assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.
Phase IV Engineering assumes no responsibility for any loss or claims by third parties that may arise through the use of this product.
Phase IV Engineering assumes no responsibility for any damage or loss caused by deletion of data as a result of malfunction, repairs, or battery replacement, or power failure.
Phase IV Engineering, Incorporated may have patents, patent applications, trademarks, copyrights, or other intellectual property rights covering subject matter in this document. Except as expressly provided in any written license agreement from Phase IV Engineering, the furnishing of this document does not give you any license to these patents, trademarks, copyrights, or other intellectual property.
This manual, its related hardware, software and documentation are subject to change without notice and do not represent a commitment on the part of Phase IV Engineering. Phase IV Engineering reserves the right to make changes in the product design without reservation and without notification to its users.
© 2021 by Phase IV Engineering, Incorporated, 2820 Wilderness Place, Unit C, Boulder, Colorado 80301, USA. All rights reserved.
All brands and product names are trademarks or registered trademarks of their respective owners.
About this Manual
This User Manual describes specific configuration and usage of the Leap Flood Sensor Device.
For general information on the Leap Wireless Sensor system, see the Quick Start Guide and the main user manual – 53-100187-01.
Hardware Configuration – Water Detection
The Pulsar Flow Meter is powered seperately and outputs a 4-20mA signal that translates to a water flow.
This user manual explains how to connect the Leap Sensor Device Node to the Pulsar sensor to bring the 4-20mA signal into the Leap Device Node.
Connecting the Leap Device to the Pulsar Flow Meter
The cable exiting the Leap Sensor Device has 4 wires:
- Yellow – 4-20mA signal into the Leap Sensor – connect to the “A+” in the Pulsar meter.
- Black – Ground – connect to the “A-“ on the pulsar meter
- Red – not used
- White – not used
Leap Terminal Block Pin-Out
The pin-out to the terminal block inside the Leap Module is shown below.
To open the lid of the Leap Node, use a screwdriver in the slot on the right side. Press down, then pivot to the right to pop open the hinge. See the video demonstration of opening the lid:
https://www.phaseivengr.com/about-us/support/ “Opening & Closing the Transceiver Node Enclosure” For a 4-20 mA sensor, the pin-out is shown below.
For the Pulsar Flow sensor
- The red wire is not connected because the Leap sensor is not powering the sensor.
- White wire is not connected to the Leap sensor
- The cable shield is not connected
Software Interface
Converting the 4-20mA signal to a flow measurement
The configuration menu allows you to convert the 4-20mA signal to a flow measurement. See the screenshots below.
SCREEN SHOTS OF 4-20 CONVERSION
Bench Testing the Leap Sensor with the Pulsar Flow Meter
The Pulsar Flow Meter has a simulation mode where it can output a user-set output. This is useful when testing the Leap sensor connection to the 4-20mA output.
Follow the instruction with the Pulsar meter to get into the simulation mode.
Technical Support
For more information about our products and services, or for technical assistance:
Visit us at: www.phaseivengr.com
Tel: +(303) 443 6611 (USA – MST 8:00 a.m. to 5:00 p.m., Mon.-Fri.)
E-Mail: support@phaseivengr.com
If you need assistance, please provide the product part number, product serial number, and product version.
LEAP SYSTEM User’s Operating Manual
2820 Wilderness Place, Unit C Boulder, Colorado, 80301
Tel: (303) 443 6611
Documents / Resources
![]() |
LEAP SENSORS 53-100187-24 Leap Wireless Sensor System [pdf] User Manual 53-100187-24 Leap Wireless Sensor System, 53-100187-24, Leap Wireless Sensor System, Wireless Sensor System, Sensor System |