xpr logo

MTPADP-MHWO
MTPADPBK-MHWO, MTPADPS-MHWO
Keypad with integrated reader

xpr MTPADP-MHWO Keypad with Integrated Reader

INSTALLER’S MANUAL

SPECIFICATIONS

Technology: Keypad + RFID (125 KHZ, 13.5 MHz)
Interface: Wiegand, OSDP, WS4, Custom RS-485 (Factory default: Wiegand 34)
Supported credentials: EM4100 or HID Compatible , HID iClass CSN, NTAG, Mifare (Classic, Desfire, Plus, Ultralight), ISO 15693
Card encryption: Desfire EV1, EV2, EV3
Read range: Up to 6 cm
Power supply: 9 – 14 VDC, 150 mA
Sound Indicator: Internal buzzer
LED Indicators: Red, Green and Orange (Red + Green)
Built-in Micro USB connector for protocol selection, configuration and firmware update
Environmental rating: Outdoor, IP65
Operating temperature: -20°C to +50°C
Operating humidity: 5% – 95% relative humidity, non-condensing
Mounting: Surface mount
Panel connection: Terminal
Dimensions (mm): 92 x 51 x 27

MOUNTING

xpr MTPADP-MHWO Keypad with Integrated Reader - Fig 1

MOUNTING WITH MT-SPACER

xpr MTPADP-MHWO Keypad with Integrated Reader - Fig 2

xpr MTPADP-MHWO Keypad with Integrated Reader - Fig 3

Wrap the wires around the ferrite core (1 turn).
The ferrite core is provided with the kit and it is used to reduce the EMI.

TERMINAL BLOCKS AND DIPSWITCH

xpr MTPADP-MHWO Keypad with Integrated Reader - Fig 4

  1. OSDP mode: SCBK reset WS4 mode: Reader address
  2. RS-485 120 Ohm termination ON=0 OFF=1

xpr MTPADP-MHWO Keypad with Integrated Reader - Fig 5

TERMINALS AND DESCRIPTION

TERMINALS DESCRIPTION OSDP CONFIGURATION WS4 CONFIGURATION WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
A RS-485 line RS-485 A (.) R5-485 A (+) xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 RS-485 A (+)
B RS-485 line RS-485 B (-) RS-485 B (-) xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 Rs-465 8 (-)
DO Output xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 DO xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1
DI Output xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 D1 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1
LG Input Input 1 (Dry contact to GND only) xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 Green LED input Green LED input
LR Input Input 1 (Dry contact to GND only) xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 Red LEO input Red LEO input
BUZZ Input xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 Buzzer input Buzzer input
+12V Power Supply xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2
GND Ground xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2
T Tamper xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1
(Tamper state is reported by
RS-485)
xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1
(Tamper state is reported by
RS-485)
xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2
T Thrice, xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2
DIP SWITCH DESCRIPTION OSDP CONFIGURATION WS4 CONFIGURATION WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
SW 1 Setup SCBK Reset Power the reader. Set DIP Switch 1 to ON and in the less than 5 sec set it back to OFF
position
The readers for Doors 1.0 and 2.0 must be at address 0 and those for Doors 11 and 21 at address 1. For doors equipped with 2  readers, one must be at address 0 and the other at address 1. xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2
SW 2 RS-485120 OHM
termination
xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 2
CABLING DESCRIPTION OSDP CONFIGURATION WS4 CONFIGURATION WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
Max length Cable Length 1200m 80m 150m 1200m
Cable Recommended
cable type
Muhiconductor cable
2 twisted pair with
shielding
Multiconductor cable
2 twisted pair with
shielding
Untwisted, shielded, 0.22 mm’ min. For longer distance above 20 m use larger diameter. Multiconductor
cable 2 twisted
pair with
shielding
SIGNALISATION DESCRIPTION OSDP CONFIGURATION WS4 CONFIGURATION WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
Reader
ON-Line
Reader is in
communication
with controler
Managed by Controller Managed by ControllE- Managed by
Controller
Managed by
Controller
Reader
OFF-Line
Reader lost
comunication with controler
Red LED Blinks Red LED Blinks fast xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1 xpr MTPADP-MHWO Keypad with Integrated Reader - symbol 1

SOFTWARE SETTINGS

XPR Toolbox is software for settings and firmware update of the reader. XPR Toolbox can be downloaded from a https://software.xprgroup.com/.
To setup the reader or update the firmware, run the XPR Toolbox and select ”Generation 2” and ”MTPADP-MHWO” and click on “Open” tab. Follow the instruction in the software to set up or update firmware. Connect the reader to PC using Micro USB connector. No additional power for the reader is required. If the reader is used with EWS Controller, reader setting must be done by PROS-CS software.

CARD ENCRYPTION

Cards encryption can be used with Mifare Desfire cards. Encryption provide higher level of security where card is accepted by its encrypted content instead of built in card serial number.
For OSDP, Wiegand and Custom RS-485 modes, reader should be programmed with the XPR Toolbox software to use encryption. Cards can be encrypted using application “XPR Card encoder” and desktop  reader (PROX-USB). This application is installed together with XPR Toolbox software. When used with WS4 controller, encryption is managed by the WS4 controller. When used with EWS controller, encryption, reader setting and cards are managed by PROS CS software.

ACCESSORIES (Optional)
• MT-SPACER

xpr MTPADP-MHWO Keypad with Integrated Reader - Fig 6

• MC-MINI

xpr MTPADP-MHWO Keypad with Integrated Reader - Fig 7

• USP

xpr MTPADP-MHWO Keypad with Integrated Reader - Fig 8

*Important: These accessories are not included with the reader!
CE SYMBOL This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.

xpr logo

www.xprgroup.com

Documents / Resources

xpr MTPADP-MHWO Keypad with Integrated Reader [pdf] Installation Guide
MTPADPBK-MHWO, MTPADPS-MHWO, MTPADP-MHWO, Keypad with Integrated Reader, MTPADP-MHWO Keypad with Integrated Reader, MTPADP-MHWO Keypad, Keypad
xpr MTPADP-MHWO Keypad with Integrated Reader [pdf] Instruction Manual
MTPADP-MHWO Keypad with Integrated Reader, MTPADP-MHWO, Keypad with Integrated Reader, Integrated Reader, Reader

References

Leave a comment

Your email address will not be published. Required fields are marked *