MTPADP-MHWO
MTPADPBK-MHWO, MTPADPS-MHWO
Keypad with integrated reader
INSTALLER’S MANUAL
SPECIFICATIONS
Technology: Keypad + RFID (125 KHZ, 13.5 MHz)
Interface: Wiegand, OSDP, WS4, Custom RS-485 (Factory default: Wiegand 34)
Supported credentials: EM4100 or HID Compatible , HID iClass CSN, NTAG, Mifare (Classic, Desfire, Plus, Ultralight), ISO 15693
Card encryption: Desfire EV1, EV2, EV3
Read range: Up to 6 cm
Power supply: 9 – 14 VDC, 150 mA
Sound Indicator: Internal buzzer
LED Indicators: Red, Green and Orange (Red + Green)
Built-in Micro USB connector for protocol selection, configuration and firmware update
Environmental rating: Outdoor, IP65
Operating temperature: -20°C to +50°C
Operating humidity: 5% – 95% relative humidity, non-condensing
Mounting: Surface mount
Panel connection: Terminal
Dimensions (mm): 92 x 51 x 27
MOUNTING
MOUNTING WITH MT-SPACER
Wrap the wires around the ferrite core (1 turn).
The ferrite core is provided with the kit and it is used to reduce the EMI.
TERMINAL BLOCKS AND DIPSWITCH
- OSDP mode: SCBK reset WS4 mode: Reader address
- RS-485 120 Ohm termination ON=0 OFF=1
TERMINALS AND DESCRIPTION
TERMINALS | DESCRIPTION | OSDP CONFIGURATION | WS4 CONFIGURATION | WIEGAND CONFIGURATION |
CUSTOM RS-485 CONFIGURATION |
A | RS-485 line | RS-485 A (.) | R5-485 A (+) | ![]() |
RS-485 A (+) |
B | RS-485 line | RS-485 B (-) | RS-485 B (-) | ![]() |
Rs-465 8 (-) |
DO | Output | ![]() |
![]() |
DO | ![]() |
DI | Output | ![]() |
![]() |
D1 | ![]() |
LG | Input | Input 1 (Dry contact to GND only) | ![]() |
Green LED input | Green LED input |
LR | Input | Input 1 (Dry contact to GND only) | ![]() |
Red LEO input | Red LEO input |
BUZZ | Input | ![]() |
![]() |
Buzzer input | Buzzer input |
+12V | Power Supply | ![]() |
![]() |
![]() |
![]() |
GND | Ground | ![]() |
![]() |
![]() |
![]() |
T | Tamper | ![]() (Tamper state is reported by RS-485) |
![]() (Tamper state is reported by RS-485) |
![]() |
![]() |
T | Thrice, | ![]() |
![]() |
![]() |
![]() |
DIP SWITCH | DESCRIPTION | OSDP CONFIGURATION | WS4 CONFIGURATION | WIEGAND CONFIGURATION |
CUSTOM RS-485 CONFIGURATION |
SW 1 | Setup | SCBK Reset Power the reader. Set DIP Switch 1 to ON and in the less than 5 sec set it back to OFF position |
The readers for Doors 1.0 and 2.0 must be at address 0 and those for Doors 11 and 21 at address 1. For doors equipped with 2 readers, one must be at address 0 and the other at address 1. | ![]() |
![]() |
SW 2 | RS-485120 OHM termination |
![]() |
![]() |
![]() |
![]() |
CABLING | DESCRIPTION | OSDP CONFIGURATION | WS4 CONFIGURATION | WIEGAND CONFIGURATION |
CUSTOM RS-485 CONFIGURATION |
Max length | Cable Length | 1200m | 80m | 150m | 1200m |
Cable | Recommended cable type |
Muhiconductor cable 2 twisted pair with shielding |
Multiconductor cable 2 twisted pair with shielding |
Untwisted, shielded, 0.22 mm’ min. For longer distance above 20 m use larger diameter. | Multiconductor cable 2 twisted pair with shielding |
SIGNALISATION | DESCRIPTION | OSDP CONFIGURATION | WS4 CONFIGURATION | WIEGAND CONFIGURATION |
CUSTOM RS-485 CONFIGURATION |
Reader ON-Line |
Reader is in communication with controler |
Managed by Controller | Managed by ControllE- | Managed by Controller |
Managed by Controller |
Reader OFF-Line |
Reader lost comunication with controler |
Red LED Blinks | Red LED Blinks fast | ![]() |
![]() |
SOFTWARE SETTINGS
XPR Toolbox is software for settings and firmware update of the reader. XPR Toolbox can be downloaded from a https://software.xprgroup.com/.
To setup the reader or update the firmware, run the XPR Toolbox and select ”Generation 2” and ”MTPADP-MHWO” and click on “Open” tab. Follow the instruction in the software to set up or update firmware. Connect the reader to PC using Micro USB connector. No additional power for the reader is required. If the reader is used with EWS Controller, reader setting must be done by PROS-CS software.
CARD ENCRYPTION
Cards encryption can be used with Mifare Desfire cards. Encryption provide higher level of security where card is accepted by its encrypted content instead of built in card serial number.
For OSDP, Wiegand and Custom RS-485 modes, reader should be programmed with the XPR Toolbox software to use encryption. Cards can be encrypted using application “XPR Card encoder” and desktop reader (PROX-USB). This application is installed together with XPR Toolbox software. When used with WS4 controller, encryption is managed by the WS4 controller. When used with EWS controller, encryption, reader setting and cards are managed by PROS CS software.
ACCESSORIES (Optional)
• MT-SPACER
• MC-MINI
• USP
*Important: These accessories are not included with the reader!
This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.
Documents / Resources
![]() |
xpr MTPADP-MHWO Keypad with Integrated Reader [pdf] Installation Guide MTPADPBK-MHWO, MTPADPS-MHWO, MTPADP-MHWO, Keypad with Integrated Reader, MTPADP-MHWO Keypad with Integrated Reader, MTPADP-MHWO Keypad, Keypad |
![]() |
xpr MTPADP-MHWO Keypad with Integrated Reader [pdf] Instruction Manual MTPADP-MHWO Keypad with Integrated Reader, MTPADP-MHWO, Keypad with Integrated Reader, Integrated Reader, Reader |