WEINTEK cMT3152X Display Machine Control Installation Guide

cMT3152X Display Machine Control

Specifications

  • Product: cMT3152X Series HMI
  • NEMA Rating: NEMA 4 (indoor use only)
  • Compliance: European CE requirements
  • Power Supply: DC
  • Battery: CR2032, 3V

Product Usage Instructions

1. Installation and Startup

Refer to the Installation Instruction for detailed steps. Ensure
to read all warnings and precautions before use.

2. Unpacking the Unit

Unpack the unit and check for any damage. Contact the supplier
if damage is found. Place the operator panel on a stable surface
during installation to prevent damage.

3. Installation Instructions

Follow the provided Installation Instruction for proper
installation.

4. Power Connections

Connect the positive DC line to the ‘+’ terminal and the DC
ground to the ‘-‘ terminal.

5. System Settings

Tap the Start Button to open the Setting page. Configure network
settings, system password, device information, and more from the
Setting page.

6. EasyBuilder Pro Software Settings

Adjust settings using the EasyBuilder Pro Software as
needed.

7. Communication Connections

Refer to the manual for specific communication connection
instructions.

8. Restore Factory Default

To restore factory default settings, follow the instructions in
Section 5, enter the Admin password or default ‘111111’, and press
Reset. Note that all stored data will be erased.

9. Battery Replacement

For battery replacement, use a CR2032, 3V battery. Replacement
should be done by qualified personnel only. Refer to the provided
link for disposal considerations.

FAQ

Q: What should I do if I encounter issues with noise
interference?

A: Proper wire routing and grounding are essential to ensure
proper operation and minimize noise interference. Ensure compliance
with local electrical standards and consult with authorities if
needed.

“`

cMT3152X series

Installation Instruction

1 Installation and Startup Guide

This document covers the installation of cMT3152X Series HMI, for the detailed specifications and operation, please refer to Datasheet, Brochure and EasyBuilder Pro User Manual. Please read all warnings, precautions, and instructions on the device carefully before use.

Install Environment:

NEMA Rating Electrical Environment
Environmental Considerations
Altitude IP Rating Cleaning Considerations
Warning

The HMI product is NEMA 4 rated (indoor use only).
The HMI product has been tested to conform to European CE requirements. This means that the circuitry is designed to resist the effects of electrical noise. This does not guarantee noise immunity in severe cases. Proper wire routing and grounding will insure proper operation. (1) Make sure that the displays are installed correctly and that the
operating limits are followed. Avoid installing units in environments where severe mechanical vibration or shocks are present. (2) Do not operate the unit in areas subject to explosion hazards due to flammable gases, vapors or dusts. (3) Do not install the unit where acid gas, such as SO2 exists. (4) This device should be mounted in the vertical position and for use on the flat surface enclosure. (5) For use in Pollution Degree 2 Environment and dry location. (6) Relative Humidity: 10% ~ 90% (non-condensing)
3,000 m IP 66 Clean the device using dry cloths. Do not use liquid or spray detergents for cleaning. Protection impairment if used in a manner not specified by the manufacturer. Déficit de protection si utilisé d’une manière non spécifiée par le fabricant.

2 Unpacking the Unit

Unpack and check the delivery. If damage is found, please contact the supplier. NOTE: Place the operator panel on a stable surface during installation. Dropping it or letting it
fall may cause damage.
The package includes: (1) Installation Instruction, 2-sided A4 *1 (2) Human Machine Interface *1 (3) Power Connector *1 (4) Brackets & Screws *1 pack (5) Fuse 1.6A/250V 5*20mm *1

3 Installation Instructions

Use a control box that provides enough stiffness. Cutout Dimension: 352 mm x 279 mm. Secure the operator panel in position, using all the fastening holes and the provided brackets and screws. Screw Torque: 2.6 ~ 3.9 lbf.in. (For reaching waterproof effect and preventing the panel from being deformed.) Plan for adequate space around the unit and inside the enclosure, for ventilation and cables. Consider the heat from other devices inside the enclosure. The ambient temperature around the unit must be 0 ~ 50°C. Minimum required clearances (along the overlay): Top / Bottom / Sides 15 mm Maximum panel thickness: 4.5 mm
4 Power Connections

Power Connector Specifications: Wire AWG: 24~12 Wiring Conductor Minimum Temperature: 75°C Screw Torque: 4.5 lbf-in (max.) Copper conduct only.

Spécifications du connecteur d’alimentation: AWG de fil: 24 ~ 12 Température minimale du conducteur de câblage: 75°C Couple de vis: 4.5 lbf-in (max.) Conducteur en cuivre seulement

NOTE: Connect positive DC line to the `+’ terminal and the DC ground to the `-‘ terminal.

5 System Settings
When the HMI powers up and displays an image, tap the round Start Button in the upper-left corner to open the Setting page. To configure the network, go to the Network tab, tap “configure”, and a login window will appear. The settings can be modified by entering the system password (default: 111111). In the Setting page, you can see device information, configure general settings, set HMI Time/Date/Name, and more.
6 EasyBuilder Pro Software Settings
Launch EasyBuilder Pro software, select your project file, press F7 shortcut key to open the download dialog box: Select Ethernet > IP tab > Enter your HMI IP > Click Download to download this project file to HMI. Using screensaver and backlight saver is recommended in order to avoid image persistence caused by displaying the same image on HMI for a long time. Flash memory has a limited write lifespan, and frequent data writing (e.g., Event Log, Data Sampling) can accelerate degradation. Consider write frequency and lifespan management in system design to prevent data loss. Refer to “3.2.1. Prolong the Lifespan of Flash Memory” in the Product Security User Manual for guidance. (Please refer to EasyBuilder Pro User Manual for software operation details.)

7 Communication Connections
NOTE:
1. Only Tx & Rx (no RTS/CTS) may be used for COM1 RS-232 when COM3 RS-232 is also used. 2. COM1 / COM3 RS-485 2W Supports MPI 187.5K, please use one at a time. 3. Use #4-40 UNC screws for the D-SUB connector installation.

Con.B

COM1/COM3 [RS232] 9 Pin, Male, D-sub

PIN#
1 2 3 4 5 6 7 8 9

COM1

COM3

[RS232]4W [RS232]2W

RxD TxD

GND

RTS

TxD

CTS

RxD

GND

Con.A

COM1/COM3 [RS485] 9 Pin, Female, D-sub

PIN#
1 2 3 4 5 6 7 8 9

COM1 [RS485]2W
DataData+

COM1 [RS485]4W
RxRx+ TxTx+ GND

COM3 [RS485]2W
DataData+

8 Restore Factory Default
To restore factory default, follow section 5 instructions of this manual to open the Setting page, and then select “System Properties”, press “Reset HMI to Default”, enter the Admin password or “default111111”, and press “Reset”. Please note that all stored project files and data will be erased.
9 Battery Replacement
Battery Specification: Type CR2032, Rated 3V Battery replacement shall be performed by qualified personnel (engineer) only and care must be taken when handling lithium batteries. For more information on battery replacement and disposal considerations, please refer to the following link: http://www.weintek.com/download/MT8000/eng/FAQ/FAQ_103_Replace_Battery_en.pdf

CAUTION
Power

NOTE: Make sure that all local and national electrical standards are met when installing the unit. Contact your local authorities to determine which codes apply.
Use power output that meets SELV (Safety Extra-Low Voltage) requirements. The unit can be powered by DC power only, voltage range: 24±20%, compatible with most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a switching power supply. The peak starting current can be as high as 2A.

Fusing Requirements

Fuse min. rating: 1.6A/250V. Use the fuse only in DC circuit. If the display does not come on within 5 seconds of power up, remove power. An internal fuse will prevent damage if the polarity of the DC power is incorrect. Check wiring for proper connections and try to power up again. Replacing fuse shall be performed by qualified personnel only. For more information, see: http://www.weintek.com/download/MT8000/eng/FAQ/FAQ_104_Replace_Fuse_en.pdf

High Voltage

An Internal fuse will prevent damage for overcurrent condition however it isn’t guaranteed. DC voltage sources should provide proper isolation from main AC power and similar hazards.

Emergency Stop

A Hard-wired EMERGENCY STOP should be fitted in any system using an HMI to comply with ICS Safety Recommendations.

Supply Voltage Condition

Do not power the unit and inductive DC loads, or input circuitry to the controller, with the same power supply. Note: The 24 VDC output from some controllers may not have enough current to power the unit.

Wire Routing

a. Power wire length should be minimized (Max: 500m shielded, 300m unshielded). b. Please use twisted pair cables for power wire and signal wire and conform to the
impedance matching. c. If wiring is to be exposed to lightning or surges, use appropriate surge suppression
devices. d. Keep AC, high energy, and rapidly switching DC power wiring separated from signal wires. e. Add a resistor and capacitor in the parallel connection between the ungrounded DC power
supply and the frame ground. This provides a path for static and high frequency dissipation. Typical values to use are 1M Ohm and 4700pF.

DANGER
Hardware Considerations

The system designer should be aware that devices in Controller systems could fail and thereby create an unsafe condition. Furthermore, electrical interference in an operator interface can lead to equipment start-up, which could result in property damage and/or physical injury to the operator. If you use any programmable control systems that require an operator, be aware that this potential safety hazard exists and take appropriate precautions. Although the specific design steps depend on your particular application, the following precautions generally apply to installation of solid-state programmable control devices, and conform to the guidelines for installation of Controllers recommended in NEMA ICS 3-304 Control Standards.

Programming Considerations

To conform to ICS Safety Recommendations, checks should be placed in the controller to ensure that all writable registers that control critical parts of plant or machinery have limit checks built into the program, with an out-of-limit safe shut down procedure to ensure safety of personnel.
GMECF2XR0_cMT3152X_Installation_20250605

Limited Warranty
This product is limited warranted against defects in design and manufacture. The proven defective product will either be repaired or replaced, at Weintek’s discretion. This warranty shall not cover any product which is
(a) Out of warranty period which is 12 months from the manufacturing month of the HMI products. (b) Damage caused by Force Majeure, accident, negligence, improper installation or misuse. (c) Product has been repaired or taken apart by unauthorized technicians. (d) Products whose identification markings have been removed or damaged.