Temtop logo
M2000 2nd Cogeneration
Multi-functional Air Quality Detector
User Manual

Factors Affecting Air Quality

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - PM2.5

PM2.5 (Particulate Matter 2.5) refers to fine particles with a diameter of 2.5 micrometers or less. Due to its tiny size, PM2.5 can be absorbed into the bloodstream and the lungs, so that long-term exposure to the high concentration of PM2.5 environment may cause eye and nose irritation, cough, asthma,
emphysema, lung disease, heart attacks, cancer and etc.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - PM10

PM10 (Particulate Matter 10) refers to particulates with a diameter of 10 micrometers or less. Due to the larger size, it’s inhalable but penetrates no further than bronchi as larger particles can be filtered out by cilia and mucus of the nose and throat. It normally considered less harmful to health than PM2.S.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - Formaldehyde

Formaldehyde (HCHO) is a colorless and strong-smelling gas with the formula CH2O, which has been classified by IARC as Group 1 carcinogen. Long-term exposure to just low doses could cause chronic respiratory diseases, nasopharyngeal carcinoma, colon cancer, brain tumors, nuclear gene mutation and etc.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - TVOC

TVOC (Total Volatile Organic Compounds) refers to various common voes including benzene, toluene, styrene, formaldehyde and etc. Due to their volatility as well as toxicity, irritability, and carcinogenicity, long-term exposure to TVOCs can cause damage to the skin, liver, kidneys, central nervous system and etc.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - CO

CO² (Carbon Dioxide) refers to a colorless and odorless gas that is usually derived from the breath of humans and animals. High CO2 concentration
means that fresh air or ventilation is required, otherwise, it may cause problems such as drowsiness, dizziness, loss of attention, and cognitive impairment.

Important!

* Do not place the detector in heavily polluted environments (concentration of HCHO > 1.0mg/m or particle > 500g/m) for a long time; or it may cause damages to the sensor.
* Do not cover the air inlet/outlet during detection; or let fluff or hair enter the detector.
* Do not make contact with organic solvents, such as glue/adhesives/paint/alcohol, etc.
* Do not use detectors in humid places or environments with a strong odor to maintain accuracy.
* Do not use in environments containing gases listed in FAQ 6 to avoid influences on HCHO sensor.
* If battery level shows□, please charge the detector promptly to avoid effects during use (also chargeable when turned off).

Overview:

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - Overview

  1. Buzzer Status
  2. Measuring Status
  3. Display
  4. Menu Button
  5. Increase/Up
  6. USB Port
  7. Date & Time
  8. Battery Level
  9. Back Button
  10. Power/OK Button
  11. Decrease/Down/Switch (Start/Pause) Button

Operation

warning!

  • First use or unused for a long time: please put it outside over 6 hours for calibration.
  • Indoor use: keep the room/area airtight for 10 minutes to obtain more accurate results.
  • When calibrating the CO² and formaldehyde sensors, please adjust the detector to the
    calibration interface and place it outdoors in a cool and ventilated environment for S minutes.
    Detection results will be much more accurate.
  1. oN
    Press and hold the power buttonTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1for2 seconds to turn on the detector
  2. Detection
    PressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3 to enter the main menu interface (see the figure below), then press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 2to locate the option to view or set and press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1to confirm.
    Temtop M2000 2nd Generation Multi Functional Air Quality Detector - Detection2.1 View or set particles/CO²/HCHO
    2.2 View all the information
    2.3 Check data records
    2.4 Set date, time, alarm value, help document, reset to default, and language.
    Note: It takes about 3 minutes for the CO² sensor to warm up and then enter detection status.
View or Set PM2.5/CO²/HCHO

In each interface, press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3to display more functions. Take CO² interface, for example, press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3button, you may see the following function options:
Temtop M2000 2nd Generation Multi Functional Air Quality Detector - View or Seta. Pause measuring: Pause or restart detecting PM2.5.
b. Turn on/ off alarm sound: Mute/ Unmute the buzzer.
c. Display the curve: Display (or not) the PM2.5 concentration curve.
d. Alarm value setting: Set a high alarm limit.
Operation: Press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 2the button to adjust the value and pressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3 to switch digits. Then Press Save and [ to save the setting and exit the interface, or press Exit and Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3to exit without saving the setting (See the figure below).
Temtop M2000 2nd Generation Multi Functional Air Quality Detector - Alarm value settinge. Zero calibration: Calibrate the sensor to zero (not available for PM2.5). Take the CO²  interface below for example:
Temtop M2000 2nd Generation Multi Functional Air Quality Detector - ero calibrationf. Exit: Exit current interface.

View all info

The View all info interface displays all the detected data including the concentration of PM2.5, PM10, CO2, HCHO, number of particles, temperature, and humidity.
Operation: Press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3to switch between C°and °F (See the figures below).
Press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 4to pause or detect; press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 5to back to the main menu interface.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - View all infoHistory

The History interface includes Storage interval and Data export functions (See the figure
below).
Operation: PressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 2 or switch between Storage interval and Data export, then pressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1 to enter the corresponding interface.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - History

a. Storage interval: PressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3to switch between digits, Save, and Exit. When you select a digit, press A or ·” to adjust the value to your desired storage interval among 1, 5, 10, 30 and 60 minutes, then locate the option to Save and press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1to save the setting and exit the interface; or locate the option to Exit and press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1to exit the interface without saving the setting.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - torage interval

b. Data export: In this interface, you will see the following tips.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - ata export

If connected to the computer successfully by the USB cable, the detector will pop up a tip
USB connection successful; If not, it will remind you of the failure (See the figures below).

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - USB connection successful

After connecting successfully, the detector will generate in the computer a removable storage device Temtop, which contains a folder named History. The history folder includes a CSV format file listing the date and time PM2.5, PM10, CO2, and HCHO concentration (see the figure). Please save it to your computer for viewing.

Date PM2.5  PM10  co  HOHO 
2019/10/28 15:09 6 10 2038 0.081
2019/10/28 15:13 7 11 1795 0.071
2019/10/28 15:21 8 14 1914 0.059

After the data is copied and viewed, please press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 5to exit and restart the detector (See the figure below).

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - After connected successfully

Set

The Set interface displays 5 options below.

Operation: PressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 2 to select the desired option; pressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1 to enter the interface.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - Set

a. Date and time: Allows customized setting of year, month, date, and time (See the figure below).
OperaTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 2tion: Press or+” to adjust time and pressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3 to switch to the next digit. Then press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3to switch to Save or Exit. Press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1o finish the settings and exit the interface.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - Date and timeb. Alarm value: Set a high alarm limit for PM2.5, CO2, or HCHO concentration (See the figure below).
Operation: Press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 2to set a high alarm limit for PM2.5, CO2, or HCHO concentration and press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3to switch to the next digit. Then press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3to switch to Save or Exit. PressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1 to finish the settings and exit the interface.
c. Help: View the help information for using the detector (See the figure below).
Operation: Press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 2to view the information that helps you use the detector; pressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 5 to back to Set interface.

 

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - Help

d. Restore: Reset to the default parameters (See the figure below).
Operation: PressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3 to switch to Restore or Exit. Press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1to confirm the settings and exit the interface. If reset, all the customized settings will automatically turn to the default.

e. Language: Set Chinese or English as a displayed language (See the figure below).
Operation: PressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3to switch between Chinese and English, press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1to confirm; then press Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 3again to switch to Save or Exit; pressTemtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1 to finish the settings and exit.

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - Language

Multipoint Detection

Repeat (2) Detection at multiple points in the targeted area to get a more comprehensive understanding of your air quality.

0FF

The device will turn off automatically after 1 hour without any activity, you can also press and hold Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 1for 2 seconds to turn off it manually.
Note: The auto-off function is invalid in the Histogram interface.

Specifications

Model M2000 2nd Generation
Dimensions 223.5×73.5×37.5mm / 8.8×2.8×1.4in.
Battery capacity 3000mAh
Battery life 6-8h
Input DC5V; 1A
Display TFT color screen
Operation environment Temperature range: 0-50°C (32-122°F)
humidity range: 0-90% RH
Atmospheric pressure condition: late
PM2.5 Sensor: Laser PM sensor
Measuring range: 0-999 pg/m3 Resolution: 0.1 pg/m3
Accuracy: ±10 pg/m3(0-100 lag/m3) ±10%(100-500 pg/m3)
PM10 Sensor: Laser PM sensor

asuring range: 0-999 pg/m3 Resolution: 0.1 pg/m3
Accuracy: ±15 lag/m3(0-100 pg/m3) ±15%(100-500 pg/m3)

Carbon dioxide (C02) Sensor: Non-Dispersive Infrared (NOIR) CO² sensor Measuring range: 0-5000 ppm

Resolution: 1 ppm

Accuracy: ±(50 ppm + 5% reading)

HCHO Optimum measurement range:0-2 mg/m3 Measurement limits: 5 mg/m3
Resolution: 0.001mg/m3
 ccuracy: ±0.03 mg/m3(0-0.3 mg/al’)Accuracy: ±0.03mg/m(0-0.3 mg/m?)
±10%(0.3-1mg/m³)

FAQ:

Q: Why is the data reading very high/over-range after the detector is turned on?
A: As being packed in ink printed package box over time may interfere with the sensor due to the remaining organic volatile residue inside the package. Therefore, after unpacking, please put the detector in a ventilated place to help accelerate its data recovery.

Q: Why is data reading unstable?
A: As airflow in the environment is changing, the distribution of organic matter concentration may be uneven. Temp recommends trying again in low airflow areas.

Q: Why is the test result abnormal or below normal?

A:

  1. Please check whether the air inlet or outlet has been covered or fluid is in.
  2. Gently shake the detector during detection to increase the interaction with the surrounding air.
  3. The sensor may be not recovered. Please place the detector outdoors for ventilation.

Q: Can the calibration be accelerated if the detector is facing the outlet of the air conditioner/fan?
A: No. The temperature difference or airflow speed at the air conditioner/fan outlet is relatively high, which may cause condensation or temperature changes on the sensor, affecting its detection performance. Please put the detector outdoors in a cool ventilated place.

Q: Why is the PM2.5 reading constantly changing?
A: As PM2.5 concentration in the environment is changing all the time not only due to environmental factors like changes in airflow, humidity, wind direction and etc. but also due to common pollutant sources like smoking, cooking; exhaust emissions from vehicles, smoke from burning coal/chimneys/furnaces and etc. All these may influence the PM2.5 concentrations and give differences in the readings.

Q: Why is the HCHO reading inaccurate or overestimated at some points?
A: As Temtop uses a high-precision electrochemical HCHO sensor, its electrochemical reaction characteristics could also respond to other gases besides formaldehyde. This table lists the most common gases that interfere with the relative sensitivities of the HCHO sensor:

Interference Gas Relative Sensitivity (%)
Carbon monoxide (CO) 1
Hydrogen (H2) 0.1
Ethyl alcohol 50
Phenols 7
Sulphur dioxide(502) 12
Ammonia (NH3) 0

Q: Which reference standards have been used to indicate the pollution levels?
A: Reference Standards for Particles and CO2 are shown below.

Status Good Moderate Unhealthy for Sensitive Groups Unhealthy Very
Unhealthy
Hazardous
Pollutant
PM2.5

(μg/m3)

≤12 12.1∼35.4 35.5∼55.4 55.5∼150.4 150.5∼250.4 ≥250.5
PM10

(μg/m3)

≤54 54.1∼154 1541∼255 255.1∼354 354.1∼424 ≥425
CO2

(PPm)

≤700 701∼1000 1001∼1500 1501∼2500 2501∼5000 ≥5001

Reference Standard for HCHO is shown below. 

Status Healthy Un Healthy 
Pollutant
HCHO (mg/m3) ≤0.1 >0.1

What’s Included

Detector x 1
USB Cable x 1
User Manual x 1

Warranty

Temp warrants the included item for 1 year from the date of original purchase. The item can be exchanged or returned within 30 days if the defect is not caused by artificial damage.

Item  Warranty Period 
Detector 1 year
Accessories N/A

Before returning or sending for repair, please check if the following items are ready:

Detector & Accessories Complete Package Proof of Purchase* Gift (if any)
Return
Exchange
Repair

Including invoice, order number, etc.

Temp warranty does NOT include:

  • Malfunction or damages caused by artificial damage or modification
  • Other deliberate damages.
  • Damages caused by force majeure events.

Temtop logo

Elitech Technology, Inc.
2528 Qume Dr, Ste 2
San Jose, CA 95131 USA
Tel: +1408-898-2866
Sales: sales@temtopus.com
Website: www.temtopus.com

Elitech (UK) Limited
Unit 13 Greenwich Business Park,
53 Norman Road, London, SE10 9QF
Tel: +44 (0) 208-858-1888
Support: service@elitech.uk.com
Website: www.elitecheu.com

Elitech Brazil Ltda
R.Dona Rosalina,90 – Lgara, Canoas – RS 92410-695,Brazil
Tel: +(55)51-3939-8634
Sales: brasil@e-elitech.com
Website: www.elitechbrasil.com.br

Temtop M2000 2nd Generation Multi Functional Air Quality Detector - icon 6