LED Dimmer
Model No.: V1-C
3-button / RF dimming / Four PWM frequency / Multiple protection
User Manual
Ver 1.0.0
Features
- 1 channel constant voltage LED RF dimmer with 3-button.
- Switch and dimming by 3 buttons.
- Match with RF 2.4G single zone or multiple zone dimming remote control optional.
- One RF controller accept up to 10 remote control.
- 4096 levels 0-100% dimming smoothly without any
- PWM frequency 500Hz, 2KHz, 8KHz or 16KHz selectable.
- Over-heat / Over-load / Short circuit protection, recover automatically.
Technical Parameters
Input and Output
Input voltage | 12-24VDC |
Input current | 20.5A |
Output voltage | 12-24VDC |
Output current | 20A@500Hz/2KHz 15A@8KHz 12A@16KHz |
Output power | 240-480W@500Hz/2KHz 180-360W@8KHz 144-288W@16KHz |
Environment
Operation temperature | Ta: -30ºC ~ +55ºC |
Case temperature (Max.) | Tc: +85ºC |
Dimming data
Input signal | 3-button + RF 2.4GHz |
Control distance | 30m(Barrier-free space) |
Dimming gray scale | 4096 (2^12) levels |
Dimming range | 0-100% |
Dimming curve | Logarithmic |
PWM frequency | 500Hz/2KHz/8KHz/16KHz |
Warranty and Protection
Warranty | 5 years |
Protection | Reverse polarity Over-heat Over-load Short circuit |
Safety and EMC
EMC standard (EMC) | ETSI EN 301 489-1 V2.2.3 ETSI EN 301 489-17 V3.2.4 |
Safety standard(LVD) | EN 62368-1:2020+A11:2020 |
Radio Equipment(RED) | ETSI EN 300 328 V2.2.2 |
Certi | CE,EMC,LVD,RED |
Package
Size | L100 x W46 x H38mm |
Gross weight | 0.081kg |
Mechanical Structures and Installations
Wiring Diagram
![]() |
Increase brightness, short press 10 levels, long press 1-6s for continuous 256 levels adjustment. |
![]() |
Turn on or off light. |
![]() |
Decrease brightness, short press 10 levels, long press 1-6s for continuous 256 levels adjustment. |
PWM frequency setting
We can select four PWM frequency: 500Hz, 2KHz, 8KHz or 16KHz.
Higher PWM frequency, will cause lower output current, higher power noise, but more suitable for camera(No flickers for video).
Match Remote Control (two match ways)
End user can choose the suitable match/delete ways. Two options are offered for selection:
Use the controller’s button
Match:
Long press button1 and button 3 for 2s, immediately press on/off key (single zone remote) or zone key (multiple zone remote) of the remote.
Delete: Press and hold button1 and button 3 for 5s to delete all match,
The light blinks 5 times means all matched remotes were deleted.
Use Power Restart
Match:
Switch off the power, then switch on power again, repeat again, immediately short press on/off key (single zone remote) or zone key (multiple zone remote) 3 times on the remote.
The light blinks 3 times means match is successful.
Delete:
Switch off the power, then switch on power again, repeat again, immediately short press on/off key (single zone remote) or zone key (multiple zone remote) 5 times on the remote.
The light blinks 5 times means all matched remotes were deleted.
Dimming Curve
Installation Precautions
- The products shall not be stacked, the distance should be ≥ 20cm, so as not to affect lifespan of the products due to poor heat dissipation.
- The product shall not be installed close to the switching power supply with an interval of ≥ 20cm to avoid the radiation interference of the switching power supply.
- The installation height shall be ≥ 1m from the tening the remote control distance due to too weak reception signal.
- The products are not allowed to be close to or covered by metal objects, with an interval of ≥ 20cm to avoid signal attenuation and shorten the remote control distance.
- Avoid installation at the corner of the wall or the corner of the beam, with an interval of ≥ 20cm to avoid signal interference.