r-p-r AutoHoot Mk3 Electronic Control Unit User Guide

AutoHoot Mk3 Electronic Control Unit

AutoHoot Mk3
Quick Start Guide
OVERVIEW
AutoHoot is an electronic control unit. It has been designed for simple operation when a particular sound signal sequence is required with reliable timing.
For full user instructions and technical specification please download the AutoHoot User Manual from our website.
In practice when starting a race all that is required is to rotate the Auto switch in a clockwise direction at the start of the starting sequence. The Hoot button can be pressed at any time for other race signals like recalls, shorten course or finish signals.

Display showing the time or
countdown timer

Auto Switch Turn switch to start sequence ON: OFF:
Hoot Button Press at any time to `HOOT’ ­ does not interrupt active Auto sequence

©2024 Richard Paul Russell Limited, The Lodge, Unit 1 Barnes Farm Business Park, Barnes Lane,

Milford on Sea, Lymington, Hampshire, SO41 0AP UK

Tel +44 (0) 1590 641223 e-mail: sales@r-p-r.co.uk web: www.r-p-r.co.uk

– 1 –

008SL044/1 1/10/2024

AutoHoot Mk3
Quick Start Guide
INSTALLATION Horn / Sounder: A 12V horn or sounder needs to be connected to produce a high decibel output.
Power Supply: 12V DC power is supplied via terminals 2 (-ve) and 4 (+ve) on the green connector blocks. The power supply needs to be capable of supplying sufficient current to the particular horn/sounder that is connected.

4
2
C-type USB connector for editing sequences and changing settings

3 1
CR2032 battery for time backup.

12V DC power connection: Terminal 2: –
Terminal 4: +

Horn / sounder connection: Terminal 1: Terminal 3: +

For instructions on the following features, please refer to the full AutoHoot User Manual: · Connection to PC/smart device using a C-type USB Cable · Output to PC/smart device of list & details of programmed sequences · Programming of custom sequences via PC/smart device.

©2024 Richard Paul Russell Limited, The Lodge, Unit 1 Barnes Farm Business Park, Barnes Lane,

Milford on Sea, Lymington, Hampshire, SO41 0AP UK

Tel +44 (0) 1590 641223 e-mail: sales@r-p-r.co.uk web: www.r-p-r.co.uk

– 2 –

008SL044/1 1/10/2024

AutoHoot Mk3
Quick Start Guide
CHANGING THE TIME AND SELECTING THE SEQUENCE 1.1 Indication of Active Sequence On power up the display will show momentarily software version followed by the current the active sequence:
AutoHoot | )) Sequence 1
1.2 Time Display When the Auto switch is in the off position AutoHoot displays time in 24 hours format with the hours in a smaller character size.
AutoHoot | ))
15: 02:34
1.3 Countdown Timer Display During a sequence a countdown/count up timer can be displayed. It is always displayed with a minus sign when in count down mode or a plus sign when in count up mode.
5, 4, 1, START
-04:59

©2024 Richard Paul Russell Limited, The Lodge, Unit 1 Barnes Farm Business Park, Barnes Lane,

Milford on Sea, Lymington, Hampshire, SO41 0AP UK

Tel +44 (0) 1590 641223 e-mail: sales@r-p-r.co.uk web: www.r-p-r.co.uk

– 3 –

008SL044/1 1/10/2024

1.4 Adjusting the time

AutoHoot Mk3
Quick Start Guide

With power off and the Auto switch in the off position hold the Hoot button pressed. Switch on the power keeping the Hoot button pressed for about 4 seconds until the display shows:

Current AutoHoot time

Adjust Time
hh:mm:ss ss->

Next action prompt (adjust seconds)

Rotate Auto Switch to the ON position to adjust the seconds

Next action prompt (adjust minutes)

Zero seconds
hh:mm:ss <-mm

Seconds flashing

Press the Hoot button to zero the seconds

Rotate Auto Switch to the OFF position to adjust the minutes

Minutes flashing

Adjust minutes
hh:mm:ss hh->

Next action prompt (adjust hours)

Press the Hoot button to increment the minutes

Rotate Auto Switch to the ON position to adjust the hours

Next action prompt (save new time)

Adjust hours
hh:mm:ss enter

Hours flashing

Press the Hoot button to increment the hours

Rotate Auto Switch to the OFF position operation.

to enter the new time and resume normal AutoHoot

©2024 Richard Paul Russell Limited, The Lodge, Unit 1 Barnes Farm Business Park, Barnes Lane,

Milford on Sea, Lymington, Hampshire, SO41 0AP UK

Tel +44 (0) 1590 641223 e-mail: sales@r-p-r.co.uk web: www.r-p-r.co.uk

– 4 –

008SL044/1 1/10/2024

AutoHoot Mk3
Quick Start Guide
1.5 Selecting the Active Sequence

With power off and the Auto switch in the off position hold the Hoot button pressed. Switch on the power keeping the Hoot button pressed for about 15 seconds until the display shows Adjust Sequence with the current sequence in large digits:

10s digit flashing

Adjust Sequence
0 1

Press the Hoot button to increment 10s digit

Rotate Auto Switch to the ON position to adjust the units digit

Next action prompt (save new sequence)

Adjust Sequence
0 1 enter

1s digit flashing

Press the Hoot button to increment units digit

Rotate Auto Switch to the OFF position AutoHoot operation.

to enter the new active sequence and resume normal

Note: If the sequence selected does not exist, the active sequence will remain unchanged. Note: If the selection process is not completed, the unit will time out 15 seconds after the last action. The active sequence will remain unchanged.

SEQUENCES

AutoHoot is pre-programmed with the following sequences. The default active sequence is no 1.

No Name

Description

1 Rule 26 1.5s rep no delay RRS Rule 26 (5,4,1,start) ­ 1.5 sec hoots with long hoot at 1 min to go, multiple starts at 5 min intervals, no delay before first signal

2 Rule 26 1.5s no delay

RRS Rule 26 (5,4,1,start) ­ 1.5 sec hoots with long hoot at 1 min to go, one start only, no delay before first signal

3 Rule 26 1.5s rep 10s delay RRS Rule 26 (5,4,1,start) ­ 1.5 sec hoots with long hoot at 1 min to go, multiple starts at 5 min intervals, 10 sec delay before first signal

4 Rule 26 1.5s 10s delay

RRS Rule 26 (5,4,1,start) ­ 1.5 sec hoots with long hoot at 1 min to go, one start only, 10 sec delay before first signal

5 Rule 26 2.5s rep no delay RRS Rule 26 (5,4,1,start) ­ 2.5 sec hoots with long hoot at 1 min to go, multiple starts at 5 min intervals, no delay before first signal

6 Rule 26 2.5s no delay

RRS Rule 26 (5,4,1,start) ­ 2.5 sec hoots with long hoot at 1 min to go, one start only, no delay before first signal

7 Rule 26 2.5s rep 10s delay RRS Rule 26 (5,4,1,start) ­ 2.5 sec hoots with long hoot at 1 min to go, multiple starts at 5 min intervals, 10 sec delay before first signal

8 Rule 26 2.5s 10s delay

RRS Rule 26 (5,4,1,start) ­ 2.5 sec hoots with long hoot at 1 min to go, one start only, 10 sec delay before first signal

9 Rule 26 2.5s 10min rep no RRS Rule 26 (5,4,1,start) ­ 2.5 sec hoots with long hoot at 1 min to go, multiple

delay

starts at 10 min intervals, no delay before first signal

©2024 Richard Paul Russell Limited, The Lodge, Unit 1 Barnes Farm Business Park, Barnes Lane,

Milford on Sea, Lymington, Hampshire, SO41 0AP UK

Tel +44 (0) 1590 641223 e-mail: sales@r-p-r.co.uk web: www.r-p-r.co.uk

– 5 –

008SL044/1 1/10/2024

AutoHoot Mk3
Quick Start Guide

No Name 10 Rule 26 2.5s 10min rep 10s
delay 11 3,2,1(long),0 rep no delay
12 3,2,1(long),0 no delay

Description RRS Rule 26 (5,4,1,start) ­ 2.5 sec hoots with long hoot at 1 min to go, multiple starts at 10 min intervals, 10 sec delay before first signal 3,2,1,start with long hoot at 1 min ­ multiple starts at 3 min intervals, no delay before first signal 3,2,1,start with long hoot at 1 min ­ one start only, no delay before first signal

13 3,2,1(long),0 rep 10s delay 14 3,2,1(long),0 10s delay

3,2,1,start with long hoot at 1 min ­ multiple starts at 3 min intervals, 10 sec delay before first signal 3,2,1,start with long hoot at 1 min ­ one start only, 10 sec delay before first signal

15 5 min hoots

1 signal every 5 min

16 4 min hoots

1 signal every 4 min

17 3 min hoots

1 signal every 3 min

18 2 min hoots

1 signal every 2 min

19 1 min hoots

1 signal every 1 min

20 5 min count-down

5 min count-down to start ­ 5 long hoots at 5 min, 4 at 4 min, 3 at 3 min, 2 at 2 min, 1 long & 3 short at 1 min 30 sec, 1 long at 1 min, 3 short at 30 sec, 2 short at

20, 1 short at 10 & 5,4,3,2 & 1 sec & 1 long at start, one start only

22 3 min count-down (Appx S)

US Sailing RRS Appendix S Sound-Signal Starting System (includes 3 long hoots at 3 min, 2 at 2 min, 1 long & 3 short at 1 min 30 sec, 1 long at 1 min, 3 short at 30 sec, 2 short at 20, 1 short at 10 & 5,4,3,2,1 sec & 1 long at start, one start only)

23

24 1 min count-down

1 min count-down to start ­ 1 long hoot at 1 min, 3 short at 30 sec, 2 short at 20, 1 short at 10 & 5,4,3,2 & 1 sec & 1 long at start, one start only

26 3 min team race

Team Racing Start ­ 3 long hoots at 3 min, 2 at 2 min, 1 at 1 min, 3 short at 30 sec, 2 short at 20, 1 short at 10 & 5,4,3,2,1 sec & 1 long at start, one start only

27 3 min team race rep.

As per No.26 but with multiple starts at 3min 30s intervals

28 3 min team race rep 4min

As per No.26 but with multiple starts at 4 min intervals

29 3 min team race rep 5min

As per No.26 but with multiple starts at 5 min intervals

30 3 min team race rep 6min

As per No.26 but with multiple starts at 6 min intervals

31 7min match race 5 min rep

RRS Appendix C 3.1 Match Racing Starting Signals with `Attention signal’ at 7 min before first start, start signal is the warning for next flight (i.e. starts at 5 min

intervals)

32 Olympic start sequence

2024 Olympic SI 12.4.1

33 Olympic medal race sequence 2024 Olympic SI 12.4.2

34 App B3 reaching starts

RRS Appx B3 Windsurfing reaching starts. 3min no sound, 2min warning, 1min

preparatory, 30sec no sound, start

36 fog horn powered underway ColRegs – Signals in Restricted Visibility – Power-Driven Vessels Underway ­ 1

prolonged blast every 1 min

37 Fog horn sailing

ColRegs – Signals in Restricted Visibility – Sailing Vessels Underway ­ 1 prolonged

blast followed by two short blasts every 1 min

38 Radio Sailing E3.4(a) rep 2min RRS Appx E3.4(a) Multiple starts at 2 min intervals

39 Radio Sailing E3.4(a) rep 3min RRS Appx E3.4(a) Multiple starts at 3 min intervals

40 Alarm Clock 7am

One hoot at 7am

As new sequences are requested or developed this list is subject to change. AutoHoot Mk3 is fully programmable, and the user can add or amend sequences as required.

©2024 Richard Paul Russell Limited, The Lodge, Unit 1 Barnes Farm Business Park, Barnes Lane,

Milford on Sea, Lymington, Hampshire, SO41 0AP UK

Tel +44 (0) 1590 641223 e-mail: sales@r-p-r.co.uk web: www.r-p-r.co.uk

– 6 –

008SL044/1 1/10/2024

Documents / Resources

r-p-r AutoHoot Mk3 Electronic Control Unit [pdf] User Guide
AutoHoot Mk3 Electronic Control Unit, AutoHoot Mk3, Electronic Control Unit, Control Unit

References

Leave a comment

Your email address will not be published. Required fields are marked *