Mitsubishi FX3U Logic Module

Mitsubishi-FX3U-Logic-Module-product-image

Product Information

The product is called PLC1.ir. It is a control device used in industrial automation systems. It is designed to interface with various other components and devices to control and monitor processes.

HMI Factory Setting:
The HMI (Human Machine Interface) of the PLC1.ir has a default setting. The default communication parameters are as follows:

  • Baud Rate: 9600
  • Data Bits: 7
  • Parity: Even
  • Stop Bits: 1

Controller Specifications:
The PLC1.ir controller has the following specifications:

  • Number of Digital Inputs: 10 (Pulse Counter Inputs included)
  • Number of Digital Outputs: 10
  • Number of Analog Inputs: 3
  • Number of Analog Outputs: 1

Compatibility:
The PLC1.ir is compatible with the DOP Series HMI Controllers and RS-422 (DOP-B Series) devices.

Product Usage Instructions

Connection Setup:
To use the PLC1.ir, follow these steps to set up the connections:

  1. Connect the PLC1.ir to the power supply using appropriate power cables.
  2. Connect the PLC1.ir to the HMI Controller or RS-422 device using compatible communication cables.
  3. Connect the required input and output devices to the PLC1.ir’s digital and analog ports.

Programming and Configuration:
To program and configure the PLC1.ir, please refer to the user manual specific to the software or programming language being used. The manual will provide detailed instructions on how to write and upload programs, configure inputs and outputs, and set up communication parameters.

Operation:
Once the PLC1.ir is connected and programmed, it can be operated by providing appropriate inputs through connected devices. The PLC1.ir will process these inputs and generate the desired outputs based on the programmed logic.

Troubleshooting:
If you encounter any issues or errors while using the PLC1.ir, please refer to the troubleshooting section of the user manual or contact our customer support for assistance.

Mitsubishi FX3U

  • HMI Factory Setting:
    • Baud rate: 9600, 7, Even, 1
    • Controller Station Number: 0 (no PLC station number in protocol, therefore, only 1(HMI) to 1(PLC) communication is allowed.)
    • Control Area / Status Area: D0 / D10

Connection

RS-422 (DOP-A/AE Series)Mitsubishi-FX3U-Logic-Module-fig- (1) RS-422 (DOP-AS35/AS38/AS57 Series)Mitsubishi-FX3U-Logic-Module-fig- (2) RS-422 (DOP-B Series)Mitsubishi-FX3U-Logic-Module-fig- (3) RS-232 (DOP-B Series)Mitsubishi-FX3U-Logic-Module-fig- (4) RS-485 (DOP-B Series)Mitsubishi-FX3U-Logic-Module-fig- (5)

Definition of PLC Read/Write Address

Registers

Type Format Read/Write Range Data Length Note
Word No. (n)
Auxiliary Relay Mn M0 – M7664 Word 1
Special Auxiliary Relay Mn M8000 – M8496 Word 1
Status Relay Sn S0 – S4080 Word 1
Input Relay Xn X0 – X360 Word Octal, 1
Output Relay Yn Y0 – Y360 Word Octal, 1
Timer PV Tn T0 – T511 Word
16 – bit Counter PV Cn C0 – C199 Word
32 – bit Counter PV Cn C200 – C255 Double Word
Data Register Dn D0 – D7999 Word
Special Data Register Dn D8000 – D8511 Word
Extension Register Rn R0 – R32767 Word

Contacts

Type Format Read/Write Range Note
Bit No. (b)
Auxiliary Relay Mb M0 – M7679
Special Auxiliary Relay Mb M8000 – M8511
Status Relay Sb S0 – S4095
Input Relay Xb X0 – X377 Octal
Output Relay Yb Y0 – Y377 Octal
Timer Flag Tb T0 – T511
Counter Flag Cb C0 – C255

NOTE

  1. The device address must be the multiple of 16.

V1.03 Revision January, 2016