MEAN WELL RT-50 Series Triple Output Switching Power Supply
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 1050C long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 700C
- Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty
GTIN CODE
MW Search: https://www.meanweII.com/serviceGTIN.aspx
SPECIFICATION
MODEL | RT-50A | RT-50B | RT-50C | RT-50D | |||||||||
OUTPUT |
OUTPUT NUMBER | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC VOLTAGE | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 24V | 12V | |
RATED CURRENT | 4A | 2A | 0.5A | 4A | 2A | 0.5A | 4A | 1.5A | 0.5A | 3A | 1A | 1A | |
CURRENT RANGE Note.3 | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 1A | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 1A | 0 ~ 5A | 0 ~ 2A | 0 ~ 1A | 0 ~ 5A | 0 ~ 1.5A | 0 ~ 1A | |
RATED POWER | 46.5W | 50W | 50W | 51W | |||||||||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 100mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 80mVp-p | 150mVp-p | 120mVp-p | |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | |||||||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±8.0% | ±3.0% | ±2.0% | ±8.0% | ±3.0% | ±2.0% | ±8.0% | ±3.0% | ±2.0% | ±8.0% | ±6.0% | |
LINE REGULATION Note.4 | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±2.0% | ±2.0% | |
LOAD REGULATION Note.5 | ±1.0% | ±3.0% | ±1.0% | ±1.0% | ±3.0% | ±1.0% | ±1.0% | ±3.0% | ±1.0% | ±1.0% | ±3.0% | ±4.0% | |
SETUP, RISE TIME | 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||||||||
HOLD UP TIME (Typ.) | 60ms/230VAC 10ms/115VAC at full load | ||||||||||||
INPUT |
VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||
EFFICIENCY (Typ.) | 75.5% | 75.5% | 76% | 78% | |||||||||
AC CURRENT (Typ.) | 1.3A/115VAC 0.8A/230VAC | ||||||||||||
INRUSH CURRENT (Typ.) | COLD START 48A/230VAC | ||||||||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||||||||
PROTECTION |
OVERLOAD |
110 ~ 150% rated output power | |||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
OVER VOLTAGE | CH1: 5.75 ~ 6.75V | ||||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
ENVIRONMENT |
WORKING TEMP. | -25 ~ +70℃ (Refer to “Derating Curve”) | |||||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃)on +5V output | ||||||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||||||||
SAFETY & EMC (Note 6) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, BIS IS13252(Part1): 2010/IEC 60950-1:2005 approved | |||||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | ||||||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035,BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020 | ||||||||||||
OTHERS |
MTBF | 2788.1K hrs min. Telcordia SR-332 (Bellcore) ; 504.7K hrs min. MIL-HDBK-217F (25℃) | |||||||||||
DIMENSION | 99*97*36mm (L*W*H) | ||||||||||||
PACKING | 0.41Kg; 45pcs/19.5Kg/0.94CUFT | ||||||||||||
NOTE |
Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Mechanical Specification
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Downloaded from Arrow.com
FAQs
- Q: What should I do if the LED indicator does not turn on?
A: Check the input power source and connections. Ensure the power supply is receiving the correct voltage. - Q: Can I adjust the output voltage range?
A: The voltage adjustment range is specified for each output channel. Refer to the user manual for details on adjusting voltages.
Documents / Resources
![]() |
MEAN WELL RT-50 Series Triple Output Switching Power Supply [pdf] Installation Guide RT-50A, RT-50B, RT-50C, RT-50D, RT-50 Series Triple Output Switching Power Supply, RT-50 Series, Triple Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |