MEAN WELL HRPG-600 600W Single Output With PFC Function

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-product

Product Specifications

  • Model: HRPG-600 series
  • Power Output: 600W
  • Input: Universal AC input / Full range
  • Power Factor Correction (PFC): Built-in active PFC function, PF>0.93
  • Efficiency: Up to 89%
  • Surge Input Protection: Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling: Built-in cooling fan with ON-OFF control
  • Signal Output: Built-in DC OK signal
  • Remote Control: Built-in remote ON-OFF control
  • Standby Output: 5V @ 0.3A
  • Remote Sense Function: Built-in remote sense function
  • No Load Power Consumption: 0.93/230VAC PF > 0.99/115VAC at full load

Product Usage Instructions

Installation:

  1. Ensure the input power matches the specifications provided.
  2. Connect the output to the device requiring power.

Operation:

  1. Turn on the power supply using the built-in remote ON-OFF control or switch.
  2. Monitor the DC OK signal to ensure proper functioning.

Maintenance:

  1. Regularly clean the cooling fan to prevent dust accumulation.
  2. Check for any signs of overheating and address promptly.

FAQ

  • Q: What should I do if the unit encounters a short circuit?
    • A: The unit is equipped with short circuit protection. Disconnect the load and investigate the cause of the short circuit before resetting the unit.
  • Q: Can I use the power supply for both 115VAC and 230VAC inputs?
    • A: Yes, the power supply is designed to work with universal AC input ranging from 90VAC to 264VAC, allowing you to use it with both 115VAC and 230VAC inputs.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.93
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in cooling fan ON-OFF control
  • Built-in DC OK signal
  • Built-in remote ON-OFF control
  • Standby 5V@0.3A
  • Built-in remote sense function
  • No load power consumption<0.75W (Note.6)
  • Current sharing up to 2400W (3+1) (24V,36V,48V)
  • 5 years warranty

SPECIFICATION

MODEL HRPG-600-3.3 HRPG-600-5 HRPG-600-7.5 HRPG-600-12 HRPG-600-15 HRPG-600-24 HRPG-600-36 HRPG-600-48
 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V
RATED CURRENT 120A 120A 80A 53A 43A 27A 17.5A 13A
CURRENT RANGE 0 ~ 120A 0 ~ 120A 0 ~ 80A 0 ~ 53A 0 ~ 43A 0 ~ 27A 0 ~ 17.5A 0 ~ 13A
RATED POWER 396W 600W 600W 636W 645W 648W 630W 624W
RIPPLE & NOISE (max.) Note.2 120mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
VOLTAGE ADJ. RANGE 2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 1000ms, 50ms/230VAC                 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC                 16ms/115VAC at full load
 

 

 

 

INPUT

VOLTAGE RANGE               Note.4 85 ~ 264VAC              120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC                  PF>0.99/115VAC at full load
EFFICIENCY (Typ.) 78.5% 82% 86% 88% 88% 88% 89% 89%
AC CURRENT (Typ.) 7.6A/115VAC              3.6A/230VAC
INRUSH CURRENT (Typ.) 35A/115VAC                70A/230VAC
LEAKAGE CURRENT <1.2mA / 240VAC
 

 

 

PROTECTION

 

OVERLOAD

105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
 

OVER VOLTAGE

3.96 ~ 4.62V 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
 

 

FUNCTION

5V STANDBY 5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.)
DC OK SIGNAL PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
REMOTE CONTROL RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
FAN CONTROL (Typ.) Load 35±15% or RTH2≧50℃ Fan on
 

 

 

ENVIRONMENT

WORKING TEMP. -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 7)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, heavy industry level, EAC TP TC 020
 

OTHERS

MTBF 1142.5K hrs min.         Telcordia SR-332 (Bellcore) ; 138.5K hrs min.           MIL-HDBK-217F (25℃)
DIMENSION 218*105*63.5mm  (L*W*H)
PACKING 1.58Kg;8pcs/13.6Kg/1.34CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  6. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) 0 ~ 0.8V or short.
  7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Case No. 977A
Unit: mm

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-3

AC Input Terminal Pin No. Assignment

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-12

DC Output Terminal Pin No. Assignment

Pin No. Assignment
1~3 -V
4~6 +V

Connector Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent

Pin No. Assignment Pin No. Assignment Mating Housing Terminal
1 AUXG 6,8 GND HRS DF11-10DS or equivalent HRS DF11-**SC or equivalent
2 AUX 7 DC-OK
3 RC+ 9 +S
4 RC- 10 -S
5 CS    

Block Diagram

PWM fosc: 70KHz

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-4

Derating Curve

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-5

Output Derating VS Input Voltage

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-6

Functions Information

Function Description of CN100

Pin No. Function Description
1 AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
2 AUX Auxiliary voltage output, 4.75~5.25V, referenced to pin 1(AUXG). The maximum load current is 0.3A. This output is not controlled by the “remote ON/OFF control”.
3 RC+ Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power OFF, Open: Power ON.
4 RC- Remote control ground.
5 CS Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance between units.
6,8 GND This pin connects to the negative terminal(-V). Return for DC-OK signal output.
7 DC-OK DC-OK signal is a TTL level signal, referenced to pin8(DC-OK GND). High when PSU turns on.
9 +S Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
10 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.

Function Manual

Remote Sense

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-7

  • The remote sensing compensates voltage drop on the load wiring up to 0.5V.

DC-OK Signal

DC-OK signal is a TTL level signal. High when PSU turns on.

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-8

Between DC-OK(pin7) and GND(pin6,8) Output Status
3.3 ~ 5.6V ON
0 ~ 1V OFF

Remote Control

The PSU can be turned ON/OFF by using the “Remote Control” function.

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-9

Between RC+(pin3) and RC-(pin4) Output Status
SW ON (Short) OFF
SW OFF (Open) ON

Current Sharing with Remote Sensing (Only for 24V, 36V and 48V)

HRPG-600 has the built-in active current sharing function and can be connected in parallel to provide higher output power:

  1. Parallel operation is available by connecting the units shown as below. (+S,-S, CS and GND are connected mutually in parallel).
  2. Difference of output voltages among parallel units should be less than 2%.
  3. The total output current must not exceed the value determined by the following equation. (output current at parallel operation) =(Rated current per unit) X (Number of unit) X 0.9
  4. In parallel operation 4 units is the maximum, please consult the manufacturer for applications of more connecting in parallel.
  5. The power supplies should be paralleled using short and large diameter wiring and then connected to the load.

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-10

Note

  1. In parallel connection, maybe only one unit (master) operate if the total output load is less than 2% of rated load condition.
    • The other PSU (slave) may go into standby mode and its output LED and relay will not turn on.
  2. 2% min. of dummy load is required.

More Information

GTIN CODE

User’s Manual

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-1

MEAN-WELL-HRPG-600-600W-Single-Output-With-PFC-Function-fig-2

Documents / Resources

MEAN WELL HRPG-600 600W Single Output With PFC Function [pdf] User Guide
HRPG-600 600W Single Output With PFC Function, HRPG-600, 600W Single Output With PFC Function, Single Output With PFC Function, With PFC Function, PFC Function, Function

References

Leave a comment

Your email address will not be published. Required fields are marked *