Product Specifications
- Model: HRPG-600 series
- Power Output: 600W
- Input: Universal AC input / Full range
- Power Factor Correction (PFC): Built-in active PFC function, PF>0.93
- Efficiency: Up to 89%
- Surge Input Protection: Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling: Built-in cooling fan with ON-OFF control
- Signal Output: Built-in DC OK signal
- Remote Control: Built-in remote ON-OFF control
- Standby Output: 5V @ 0.3A
- Remote Sense Function: Built-in remote sense function
- No Load Power Consumption: 0.93/230VAC PF > 0.99/115VAC at full load
Product Usage Instructions
Installation:
- Ensure the input power matches the specifications provided.
- Connect the output to the device requiring power.
Operation:
- Turn on the power supply using the built-in remote ON-OFF control or switch.
- Monitor the DC OK signal to ensure proper functioning.
Maintenance:
- Regularly clean the cooling fan to prevent dust accumulation.
- Check for any signs of overheating and address promptly.
FAQ
- Q: What should I do if the unit encounters a short circuit?
- A: The unit is equipped with short circuit protection. Disconnect the load and investigate the cause of the short circuit before resetting the unit.
- Q: Can I use the power supply for both 115VAC and 230VAC inputs?
- A: Yes, the power supply is designed to work with universal AC input ranging from 90VAC to 264VAC, allowing you to use it with both 115VAC and 230VAC inputs.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.93
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Built-in cooling fan ON-OFF control
- Built-in DC OK signal
- Built-in remote ON-OFF control
- Standby 5V@0.3A
- Built-in remote sense function
- No load power consumption<0.75W (Note.6)
- Current sharing up to 2400W (3+1) (24V,36V,48V)
- 5 years warranty
SPECIFICATION
MODEL | HRPG-600-3.3 | HRPG-600-5 | HRPG-600-7.5 | HRPG-600-12 | HRPG-600-15 | HRPG-600-24 | HRPG-600-36 | HRPG-600-48 | |
OUTPUT |
DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 120A | 120A | 80A | 53A | 43A | 27A | 17.5A | 13A | |
CURRENT RANGE | 0 ~ 120A | 0 ~ 120A | 0 ~ 80A | 0 ~ 53A | 0 ~ 43A | 0 ~ 27A | 0 ~ 17.5A | 0 ~ 13A | |
RATED POWER | 396W | 600W | 600W | 636W | 645W | 648W | 630W | 624W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | |
VOLTAGE ADJ. RANGE | 2.8 ~ 3.8V | 4.3 ~ 5.8V | 6.8 ~ 9V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 28.8 ~ 39.6V | 40.8 ~ 55.2V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load | ||||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC at full load | ||||||||
INPUT |
VOLTAGE RANGE Note.4 | 85 ~ 264VAC 120 ~ 370VDC | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
POWER FACTOR (Typ.) | PF>0.93/230VAC PF>0.99/115VAC at full load | ||||||||
EFFICIENCY (Typ.) | 78.5% | 82% | 86% | 88% | 88% | 88% | 89% | 89% | |
AC CURRENT (Typ.) | 7.6A/115VAC 3.6A/230VAC | ||||||||
INRUSH CURRENT (Typ.) | 35A/115VAC 70A/230VAC | ||||||||
LEAKAGE CURRENT | <1.2mA / 240VAC | ||||||||
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power | |||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE |
3.96 ~ 4.62V | 6 ~ 7V | 9.4 ~ 10.9V | 14.4 ~ 16.8V | 18.8 ~ 21.8V | 30 ~ 34.8V | 41.4 ~ 48.6V | 57.6 ~ 67.2V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||||
FUNCTION |
5V STANDBY | 5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.) | |||||||
DC OK SIGNAL | PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V | ||||||||
REMOTE CONTROL | RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off | ||||||||
FAN CONTROL (Typ.) | Load 35±15% or RTH2≧50℃ Fan on | ||||||||
ENVIRONMENT |
WORKING TEMP. | -40 ~ +70℃ (Refer to “Derating Curve”) | |||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||
SAFETY & EMC (Note 7) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | ||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, heavy industry level, EAC TP TC 020 | ||||||||
OTHERS |
MTBF | 1142.5K hrs min. Telcordia SR-332 (Bellcore) ; 138.5K hrs min. MIL-HDBK-217F (25℃) | |||||||
DIMENSION | 218*105*63.5mm (L*W*H) | ||||||||
PACKING | 1.58Kg;8pcs/13.6Kg/1.34CUFT | ||||||||
NOTE |
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Mechanical Specification
Case No. 977A
Unit: mm
AC Input Terminal Pin No. Assignment
DC Output Terminal Pin No. Assignment
Pin No. | Assignment |
1~3 | -V |
4~6 | +V |
Connector Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent
Pin No. | Assignment | Pin No. | Assignment | Mating Housing | Terminal |
1 | AUXG | 6,8 | GND | HRS DF11-10DS or equivalent | HRS DF11-**SC or equivalent |
2 | AUX | 7 | DC-OK | ||
3 | RC+ | 9 | +S | ||
4 | RC- | 10 | -S | ||
5 | CS |
Block Diagram
PWM fosc: 70KHz
Derating Curve
Output Derating VS Input Voltage
Functions Information
Function Description of CN100
Pin No. | Function | Description |
1 | AUXG | Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). |
2 | AUX | Auxiliary voltage output, 4.75~5.25V, referenced to pin 1(AUXG). The maximum load current is 0.3A. This output is not controlled by the “remote ON/OFF control”. |
3 | RC+ | Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power OFF, Open: Power ON. |
4 | RC- | Remote control ground. |
5 | CS | Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance between units. |
6,8 | GND | This pin connects to the negative terminal(-V). Return for DC-OK signal output. |
7 | DC-OK | DC-OK signal is a TTL level signal, referenced to pin8(DC-OK GND). High when PSU turns on. |
9 | +S | Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. |
10 | -S | Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. |
Function Manual
Remote Sense
- The remote sensing compensates voltage drop on the load wiring up to 0.5V.
DC-OK Signal
DC-OK signal is a TTL level signal. High when PSU turns on.
Between DC-OK(pin7) and GND(pin6,8) | Output Status |
3.3 ~ 5.6V | ON |
0 ~ 1V | OFF |
Remote Control
The PSU can be turned ON/OFF by using the “Remote Control” function.
Between RC+(pin3) and RC-(pin4) | Output Status |
SW ON (Short) | OFF |
SW OFF (Open) | ON |
Current Sharing with Remote Sensing (Only for 24V, 36V and 48V)
HRPG-600 has the built-in active current sharing function and can be connected in parallel to provide higher output power:
- Parallel operation is available by connecting the units shown as below. (+S,-S, CS and GND are connected mutually in parallel).
- Difference of output voltages among parallel units should be less than 2%.
- The total output current must not exceed the value determined by the following equation. (output current at parallel operation) =(Rated current per unit) X (Number of unit) X 0.9
- In parallel operation 4 units is the maximum, please consult the manufacturer for applications of more connecting in parallel.
- The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
Note
- In parallel connection, maybe only one unit (master) operate if the total output load is less than 2% of rated load condition.
- The other PSU (slave) may go into standby mode and its output LED and relay will not turn on.