matt E ARD-1-32-TP-R-SPD Three Phase Connection Unit

matt-E-ARD-1-32-TP-R-SPD-Three-Phase-Connection-Unit-fig-1

Product Specifications

  • Input Volts: 400V 50Hz
  • Max Load: 32amps
  • Cable Entry Facility: Top and bottom
  • Terminal Capacity: 25mm2
  • Dimensions (H x W x D): 550mm x 360mm x 120mm
  • Weight: Approximately 7kg
  • Enclosure: Mild Steel Powder Coated
  • Ingress Protection: IP4X
  • Warranty: 1 Year

Product Usage Instructions

Installation:

  1. Ensure the power supply is turned off before installation.
  2. Mount the ARD connection unit securely in a suitable location.
  3. Connect the input cable to the designated terminals ensuring proper polarity.

Operation:

  1. After installation, turn on the power supply and verify proper functionality.
  2. The auto reset isolator will automatically reset in case of a fault.

Maintenance:

  1. Regularly inspect the unit for any signs of damage or wear.
  2. Clean the unit periodically to ensure optimal performance.

Frequently Asked Questions (FAQ)

  • What is the purpose of the Type 2 SPD in this product?
    The Type 2 Surge Protection Device (SPD) is designed to protect against voltage spikes and surges, enhancing the safety of connected equipment.
  • How can I reset the auto rest isolator?
    The auto reset isolator will reset automatically after a fault condition is cleared. If manual intervention is required, consult the user manual for specific instructions.

INTRODUCTION

  • The matt:e ARD connection centres with unique 5 pole auto reset device and built in Type 2 SPD.
  • Simple to install, dedicated EV connection centres with built in O-PEN® technology that allows for the connection of EV charge points to the PME earthing facility without the use of earth electrodes.
  • Helping to facilitate compliance with BS:7671. 2018 Amendment 2, 2022 Regulation 722.411.4.1.(iii).

Product Features and benefits

  • Built in O-PEN® technology
  • NO EARTH ELECTRODES REQUIRED
  • Helps reduce disruptive and costly groundworks
  • Removes the risk of striking buried services
  • Simple wire in wire out connection
  • Complete with Type 2 SPD
  • With built in 32A TPN Type A RCBO
  • Mild steel IP4X enclosure
  • Standard 1 Year parts warranty.

    matt-E-ARD-1-32-TP-R-SPD-Three-Phase-Connection-Unit-fig-2

Specifications

Input Volts 400V 50Hz
Max Load 32amps
Cable Entry Facility Top and bottom
Terminal Capacity 25mm2
Dimensions ( H x W x D ) 550mm x 360mm x 120mm
Weight Approximately 7kG
Enclosure Mild Steel Powder Coated
Ingress Protection IP4X
Warranty 1 Year