DCP250
Digital Controller Programmer
57-77-16U-18
Issue 1
Model Selection Guide
DCP251 Digital Controller Programmer
Instructions
- Select the desired Key Number. The arrow to the right marks the selection available.
- Make one selection each from Table I thru IX, using the column below the proper arrow.
- A dot (
) denotes unrestricted availability. A letter denotes restricted availability.
KEY NUMBER Description
KEY NUMBER Description | Selection | Availability |
Controller Programmer Controller Programmer with USB Port Controller Programmer w/Recording Controller Programmer w/Recording & USB Port |
DCP251 DCP252 DCP253 DCP254 |
![]() |
TABLE I – Power Supply
100 – 240 Vac 24 – 48 Vac or Vdc |
0 2 |
![]() |
TABLE II – Control Loops
One Control Loop One Control Loop + Aux Input Two Control Loops |
1 A 2 |
![]() |
TABLE III – Base Option 1
Relay Output Relay Output + Linear DC Output |
1 M |
![]() |
TABLE IV – Base Option 2
None Relay Output + Linear DC Output |
0 M |
![]() |
TABLE V – Output Slot 1
None Relay DC Drive for SSR Linear DC Output Triac Output |
0 1 2 L 8 |
![]() |
TABLE VI – Output Slot 2
None Relay DC Drive for SSR Triac Output Dual Relay Output Dual SSR Driver Output 24Vdc Xmtr Power |
0 1 2 8 9 Y T |
![]() |
Section 5
TABLE VII – Output Slot 3
None Relay DC Drive for SSR Triac Output Dual Relay Output Dual SSR Driver Output 24Vdc Xmtr Power |
0 1 2 8 9 S T |
![]() |
TABLE VIII – Options A
Slot A Options | No Selection RS485 MODBUS RTU Digital Input (Slot A) Auxilary Input (Slot A) Ethernet |
1 3 4 5 0 |
![]() |
TABLE IX – Options C
Slot C | No Selection Multiple Digital Input |
![]() |
TABLE X
Manuals/Language | English Manual French Manual German Manual Italian Manual Spanish Manual |
1 2 3 4 5 |
![]() |
TABLE XI – Extended Warranty
Extended Warranty | No Selection Extended Warranty – 1 yr. Extended Warranty – 2 yr. |
0 1 2 |
![]() |
Upgrade Kits/PC Software | Reference |
Relay Module (Slot 1) Relay Module (Slot 2 & 3) 10Vdc SSR Driver Module (Slot 1) 10Vdc SSR Driver Module (Slot 2 & 3) Dual SSR Driver Module (Slot 2 & 3) TRIAC Module (Slot 1) TRIAC Module (Slot 2 & 3) Linear (mA, Vdc) Module (Slot 1) Dual Relay Module (Slot 2 & 3) Dual SSR Output Module (Slot 2 & 3) 24V Transmitter Power Supply Module (slot 2 & 3) RS485 Communication (Slot A) Ethernet Communication (Slot A) Digital Input Module (Slot A) Basic Aux Input Module (RSP/Position) (Slot A) Program Configuration/Profile Editing Software |
51453391-517 51453391-518 51453391-502 51453391-507 51453391-519 51453391-503 51453391-508 51453391-504 51453391-510 51453391-519 51453391-511 51453391-512 51453391-521 51453391-513 51453391-515 51453391-522 |