DEEWORKS BLF Series Displacement Sensor

Displacement Sensor

USER MANUAL

Warning

  • The light source of this product use visiable laser. It is prohibited to directly or indirectly reflect the laser beam into the eyes. It may cause a risk of blindness if the laser beam enter to eyes.
  • This product does not have explosion-proof structure. Prohibit use inflammable, explosive gas or explosive liquid environments.
  • Do not disassemble or modify this product as it is not designed to automatically turn off laser emission when the product is opened. If the client disassembles or changes this product without permission, it may cause personal injury,fire, or electric shock danger.
  • Do not according the manual to control, adjust or operate may cause dangerous radiation leaks.

Attention

  • Wiring, connecting/disconnecting interfaces, and other operations when the power is turned on are very dangerous. Please be sure to turn off the power before operation.
  • Installation in the following place may cause malfunctions:

1. place full of dust or steam
2. place where have corrosive gases
3. place where water or oil can directly spill
4. place with serious vibration or impact

  • This product is not suitable use for outdoor or strong direct light.
  • Do not use this sensor in an unstable state(eg:short time after power turned on), need about 15 minutes stable.
  • If it is necessary to use a switching power regulator, please ground the grounding terminal. Do not connect to high-voltage cables or power lines. Failure to operate will cause sensor damage or malfunction,each product in differences, Therefore, there may be slight differences in the detection characteristics of the product.
  • Do not use this product in water.
  • Please do not disassemble, repair, or modify this product without authorization, as this may result in electric shock, fire, or injury to the human body.
  • Clean the dust on the transmitting or receiving components to maintain correct detection. Avoid direct impact of objects on this product
  • Operate within the rated range.

This product can not used as a safety device to protect the human body

Panel Description

Displacement Sensor

③ Press Completecalibration.(whenthedifferencebetweentwotimesteachingissmall,display Deviation too small, and it is necessary to widen the difference and teach again.)

Dimension Drawing

Displacement Sensor

Circuit Diagram

Displacement Sensor

B Limitedteaching

In the case of small objects and backgrounds

Displacement Sensor

1 Press “SET” key when in a background state or there is a detected object.
2 With the background object as the reference, press the “UP” key to set the reference value in the sensor.When the object is detected as the reference, detecting the set value of the objec after press the ” DOWN” button
3 Complete calibration

C 1 Pointteaching(windowcomparemode)

The method of setting upper and lower limit values is implemented instead of implementing 1- point teaching for the distance between the reference plane of the detected object.Use this function when discriminating within the upper and lower limits.

In the case of implementing 1-point teaching (window comparison mode),please set the detection output setting in PRO mode to [1 point teaching (window comparison mode)] in advance.

Displacement Sensor

Specifications

Displacement Sensor

D 2 Pointteaching(windowcomparemode)

In the case of implementing 2-point teaching (window comparison mode),Please set the detection output setting in PRO mode to [2-point teaching (window comparison mode)] in advance.
When teaching, please use the detection product (P-1, P-2) with different distance.

Displacement Sensor

 

Displacement Sensor

  • Press the “SET” button (1st time) when there is a detected product P-1
  • Press the “SET” button (second time) while detecting product P-2 Complete calibration

E 3 point teaching (window compare mode)

Perform 3- point (P-1, P-2, P-3) teaching, as shown in the following picture, and set the reference value 1_ SL between the 1st and 2nd times.
Set the reference value 2 SL between the 2nd and 3rd times,and the method of setting the reference value range.

In the case of 3-point teaching (window comparison mode),Please set the menu detection output setting to [3 point teaching (window comparison mode)] in advance. When teaching, please use the detection product (P-1, P-2,P-3) with different distance.

After teaching, P-1, P-2, and P-3 will be automatically arranged in ascending order.

P-1-3

Press the “SET” button (1st time) when there is a detected product P-1.
Press the “SET” button (second time) while detecting product P-2.
Press the “SET” button (3rd time) while detecting product P-3.

Complete calibration

Threshold Fine Tuning Function

No rma l l y d e t e c t i o n mo d e : Press the “UP” or “DOWN” keys to directly change the threshold
W i n d ow c omp a r i s o n mo d e : Short press the “M” key to to switch threshold 1 and threshold 2.

Zero Adjustment Function

Note: Zero adjustment requires setting the display mode to reverse mode in order to operate.

The zero adjustment function means the function of forcing  the measured value to be “set to zero”. When setting zero adjustment, there is a vertical line on the screen, as shown in the right picture:

Press the “M” and “UP” keys meanwhile to zero adjustmentsetting
Press the “M” and “UP” keys meanwhile to cancel the zero adjustment

Key Locking Function

Press the “M” and “DOWN” keys meanwhile to lock the keys.
Press the “M” and “DOWN” keys meanwhile to unlock.

Menu Setting

Press and hold the “M” key for 3 seconds in the distance display interface to enter the menu setting mode. In menu setting mode, press and hold “M” for 3 seconds to exit menu setting mode.
After enter the menu setting mode, Do not press any keys within 20 seconds, will exit the menu setting mode. press the “UP” or “DOWN” keys to switch menus up and down.Short press the “SET” key to enter the corresponding menu

Displacement Sensor

(6) External input: when selecting the corresponding function, short circuit the pink wire to the negative pole of the power supply once( more than 30ms) to ttrigger once;
Zero adjustment: The current value is reset to zero (only valid if the display mode is offset or reverse)

Teaching: It can be used as a single press ofthe “M” button

Stop measurement: The sensor stop continuous measurement and stop emitting laser at the same time.

Displacement Sensor

(8) Displaymode:Standard(actualdistance),reverse(thecenterpointoftherangeis0 points, the direction close to the sensor is positive, and vice versa is negative), offset (the farthest range is 0 points, and the distance close to the sensor direction increases)

Displacement Sensor

(9) The default is keep off, and you can select keep on by use “up” and “down” buttons, when the current detection value reaches the maximum or minimum, the output voltage or current can be maintained.【 A common application is to maintain 0 or 5v even after exceeding the range. 】

Displacement Sensor

BLF Series MODBUS Protocol

Displacement Sensor

 

Displacement Sensor

 

Displacement Sensor

 

Displacement Sensor

Communication example (acquisition distance)

Displacement Sensor

Communication example (Set the BAUD rate to 9600)

Displacement Sensor

Quanlity Guarantee

When ordering our products only reference sample, the following guarantees, disclaimers, conditions of fitness etc should apply when no special instructions are mentioned in the quotation sheet, contract, specification, etc.

Before order please ensure you read and confirming following.

1. QualityGuaranteePeriod

Quality guarantee period is one year,calculated from the date when product delivered to buyer’s destination.

2. Range of guarantee

We will repair the commodity free if the damage caused by our company.
It’s will not belong to the range of guarantee if caused by following reason :

1) Damage caused by use outside of the conditions, environment and use method described in the product manual of the company.
2) Faults not caused by our company.
3) Product damage caused by the personal modification and repair except the manufacturer.
4) Didn’t according to usage method of our company description
5) After the goods are delivered, the problem caused by unpredictable scientific level
6) Other failures caused by natural disasters, disasters and other factors
At the same time, the above guarantee only refers to the company’s products, and the other damage caused by the company’s product failure is excluded from the guarantee range.

3. Limitsofliability

1))The Company should not be liable for any special loss, indirect loss, and other related losses (eg:equipment damage, loss of opportunity, loss of profit) caused by incorrect use of company’s products.
2)When using programmable equipment, our company will not assume any responsibility for the programming  carried out by non-company personnel and the consequences arising therefrom

4. Suitableforuseandconditions

1) The products of our company are designed and manufactured for general products of general industry. So, the products of our company should not be used for the following applications and not suitable for their use.If it is necessary to be used in the following occasions, please discuss with the sales of our company to confirm the product specification, and select the product which suitable. At the same time, we should consider various safety countermeasures, such as the safety circuit that can minimize the danger even if there is a failure.

① Facilities that have a serious impact on life and property, such as atomic energy control equipment, incineration equipment, railway, aviation and vehicle equipment, medical equipment, entertainment equipment, safety devices and equipment that must comply with the special provisions of administrative agencies and individual industries.
② Public utilities such as gas, water, power supply systems, 24-hour continuous operation systems and other equipment requiring high reliability.

  • Systems, equipment and devices that may endanger personal and property.
  • Outdoor use under similar or similar conditions.

2) When the user uses the company’s products in occasions closely related to personal and property safety, the overall risk of the system should be clear. In order to ensure safety, special redundancy design should be adopted. At the same time, according to the applicable purpose of the company’s products in the system, supporting power distribution and settings should be supply.
3) Please be sure to follow the precautions and prohibitions to avoid incorrect use and damage caused by a third party.

5. RangeofServices

The product price does not include the dispatch fee of technicians and other service fees. If you have any demand in this, you can contact us to negotiate.

Specifications:

  • NPN+Analog+485
  • PNP+Analog+485
  • Sensing Range:
    • BLF-100NM-485, BLF-100PM-485: 0.1m to 1m
    • BLF-200NM-485, BLF-200PM-485: 0.1m to 2m
    • BLF-500NM-485, BLF-500PM-485: 0.1m to 5m
    • BLF-M10NM-485, BLF-M10PM-485: 0.1m to 10m
    • BLF-M20NM-485, BLF-M20PM-485: 0.1m to 20m
    • BLF-M50NM-485, BLF-M50PM-485: 0.1m to 50m
  • Resolution Ratio: 1mm

FAQ:

Q: Can this sensor be used in outdoor environments?

A: It is not recommended to use this sensor in outdoor environments as it may lead to malfunctions due to exposure to elements like rain, direct sunlight, and extreme temperatures.

Q: What should I do if the sensor is not providing accurate readings?

A: Check for any obstructions in front of the sensor that may be affecting its readings. Ensure proper calibration and alignment according to the user manual.