CORCOM Snap-In Compact RFI Filter IEC Connector Package User Guide
EAS Series
This filter offers the performance characteristics of the EEA susceptibility filter with the additional advantage of a snap-in panel mount. The EAS series supersedes the EF series by providing superior performance, particularly in the common mode at low frequencies
EBS Series
This filter offers the performance characteristics of theEEB susceptibility filter with the additional advantage of a snap-in panel mount. The EBS provides enhanced differential mode performance compared to both theEAS and EF series.
Electrical Schematic
Resistor location for reference only.
Specifications
Maximum leakage current,each line-to-ground
@ 120 VAC 60 Hz: .22 mA
@ 250 VAC 50 Hz: .38 mA
Hipot rating (one minute):
line-to-ground 1500 VAC
line-to-line 1450 VDC
Operating frequency: 50/60 Hz
Rated voltage (max.): 250 VAC
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
CurrentRating | .01 | .05 | .1 | Frequency-MHz.15 .5 1 5 | 10 | 30 | |||||||||||
EAS Models | |||||||||||||||||
1A | 12 23 | 29 | 32 | 41 | 47 | 47 | 47 | 40 | |||||||||
3A | – 10 | 15 | 19 | 30 | 36 | 48 | 50 | 47 | |||||||||
6A | – 1 | 4 | 10 | 22 | 28 | 42 | 48 | 47 | |||||||||
10A | – 1 | 3 | 5 | 14 | 20 | 32 | 38 | 47 | |||||||||
15A | – – | – | 1 | 5 | 8 | 20 | 25 | 40 | |||||||||
EBS Models1A 12 23 29 32 41 47 47 47 40 | |||||||||||||||||
3A | – 10 | 14 | 18 | 30 | 36 | 48 | 50 | 47 | |||||||||
6A | – 1 | 4 | 10 | 22 | 28 | 42 | 48 | 47 | |||||||||
10A | – 1 | 3 | 5 | 14 | 20 | 32 | 38 | 47 | |||||||||
15A | – – | – | 1 | 5 | 8 | 20 | 26 | 40 |
EAS Models1A 1 | 9 | 19 | 32 | 42 | 45 | 40 | |||
3A | 2 | 4 | 6 | 20 | 35 | 45 | 40 | ||
6A | 2 | 4 | 6 | 6 | 24 | 40 | 40 | ||
10A | 1 | 4 | 5 | 5 | 5 | 30 | 40 | ||
15A | 1 | 4 | 4 | 12 | 14 | 15 | 40 | ||
Current | Frequency-MHz | ||||||||
Rating | .01 | .15 | .5 1 3 5 | 10 | 30 | ||||
EBS Models1A 1 | 3 | 14 | 23 | 41 | 47 | 50 | 44 | ||
3A | 1 | 2 | 11 | 14 | 25 | 38 | 44 | 40 | |
6A | 1 | 2 | 10 | 14 | 20 | 33 | 42 | 40 | |
10A | 1 | 2 | 10 | 16 | 19 | 19 | 39 | 40 | |
15A | – | 2 | 10 | 16 | 24 | 28 | 28 | 40 |
Case Style
EAS1/EBS1
Typical dimensions:
Terminals: .250 [6.35] (3)
Holes: .07 [1.8] Dia.(2)
Slot: .07 x .16 [1.8 x 4.1]
Recommended Panel Cutout
Panel Thickness | G Dim.±.002 |
0.031 – 0.052 [.79 – 1.32] | 1.260 [32.00 |
0.046 – 0.068 [1.17 – 1.73] | 1.350 [34.29] |
Case Dimensions
Part No. | A (max) | B (max) | C (max) | D (max) | E (max) |
EAS1, EBS1 | 2.20 55.88 | 1.15 29.2 | 96 24.38 | 1.185 30.10 | 1.41 35.81 |
Part Numbers
1EAS1 | 1EBS1 |
3EAS1 | 3EBS1 |
6EAS1 | 6EBS1 |
10EAS1 | 10EBS1 |
15EAS1 | 15EBS1 |
Line Cord No. GA400
Insulating Boot No. FA601. GA400
Insulating Boot No. FA601
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents.
Documents / Resources
![]() |
CORCOM Snap-In Compact RFI Filter IEC Connector Package [pdf] User Guide Snap-In Compact RFI Filter IEC Connector Package, Snap-In, Compact RFI Filter IEC Connector Package, IEC Connector Package, Connector Package, Package |