Specifications

  • Model: RFS-1000
  • Frequency Range: 0.1 GHz to 42 GHz
  • Output Power: Up to +15 dBm
  • Modes: CW Mode, Sweep Mode
  • Ideal for: Lab testing, development, production
    environments

Product Usage Instructions

Assembly Instructions

  1. Install PCB:

    Insert the appropriate PCB (RFS-1220 or RFS-1420) into the
    unit’s RF chassis based on the required output channels.

  2. Mount the Front Panel:

    Secure the front panel using screws.

  3. Connect Trigger Interface:

    Attach the external trigger according to your application
    needs.

  4. Power Up & Connect:

    Connect the unit via USB or Ethernet.

  5. Access the GUI:

    Launch the GUI interface for configuration and testing. Download
    the GUI from the BNC website.

GUI Installation & Use

Download the GUI software from the BNC website under Support
> Downloads > RF & Test Measurements > Software >
RFS-1000. Unzip the downloaded folder onto your device. The GUI can
be downloaded via USB or Ethernet connection. The interface
provides easy toggles for output control, frequency selection,
power levels, and triggering.

Testing Procedure

Frequently Asked Questions (FAQ)

Q: Can I use the RFS-1000 for frequency sweeps?

A: Yes, the RFS-1000 supports user-configurable frequency sweeps
in Sweep Mode.

Q: What is the maximum output power of the RFS-1000?

A: The RFS-1000 can deliver up to +15 dBm output power.

Q: Where can I download the GUI software for RFS-1000?

A: The GUI software is available on the BNC website under
Support > Downloads > RF & Test Measurements >
Software > RFS-1000.

“`

RFS-1000

The RFS-1000 is a high-performance RF/microwave signal generator designed for CW and sweep modes. It covers a broad frequency range from 0.1 GHz to 42 GHz and delivers up to +15 dBm output power. The generator is ideal for lab testing, development, and production environments.

QUICK START GUIDE

ASSEMBLY INSTRUCTIONS
1. Install PCB: Insert the appropriate PCB — either the RFS-1220 or RFS-1420, depending on the required number of output channels — into the unit’s RF chassis.
2. Mount the Front Panel: Secure the front panel using screws. 3. Connect Trigger Interface: Attach the external trigger as required by your application. 4. Power Up & Connect: Connect the unit via USB or Ethernet. 5. Access the GUI: Launch the GUI interface to begin configuration and testing. Found in the BNC website.

GUI INSTALLATION & USE
Download available on BNC website under support > downloads > RF & Test Measurements > software > RFS-1000. After download make sure to unzip the folder onto your device. Download GUI: Required software is downloadable vis USB or Ethernet connection. Modes Available
CW Mode: Simple continuous wave signal generation Sweep Mode: User-configurable frequency sweeps tailored to your test setup User Interface: Easy-to-use with accessible toggles for output control, frequency selection, power levels, and triggering.

TESTING PROCEDURE
Use a spectrum analyzer to validate the following parameters: CW frequency output (0.1­42 GHz) Sweep accuracy and range Output power (up to +15 dBm) Trigger response (internally and externally) Reference signal stability ( ultra-low phase noise)

KEY SPECIFICATIONS
Frequency Range: 0.1 ­ 22 GHz or 0.1 GHz ­ 42 GHz Output Power: Up to +15 dBm Operation Modes: CW and Sweep Connectivity: USB, Ethernet Triggering: External trigger supported References: Ultra-low phase noise internal reference Phase Noise: -92 dBc @ 20 GHz (10 kHz offset), -90 dBc @ 40 GHz (10 kHz offset) Frequency Step Size: <2 Hz , 10 Hz Harmonic Content: < -25 dBc (typical) for both Ultra-low-noise 100 MHz VCXO locked to internal OCXO or external 10 MHz reference (±10 PPB stability oven-controlled oscillator)

REVIEW
The RFS-1000 is a compact, robust RF/microwave signal generator suitable for high-precision test environments. Designed around the RFS-1220 or RFS-1440 PCB core, this platform supports flexible configurations depending on the required number of RF channels. The device’s intuitive GUI, accessible over USB or Ethernet, enables quick setup for CW and sweep operations. Its performance has been validated using spectrum analysis, confirming fast sweep rates, stable power output, reliable triggering. The combination of ease of use, frequency coverage, and robust construction makes the RFS-1000 a reliable choice for developers and RF engineers working in demanding lab or production setting

Documents / Resources

BNC RFS-1000 High Performance RF/Microwave Signal Generator [pdf] User Guide
RFS-1220, RFS-1420, RFS-1000 High Performance RF Microwave Signal Generator, RFS-1000, High Performance RF Microwave Signal Generator, Performance RF Microwave Signal Generator, RF Microwave Signal Generator, Microwave Signal Generator, Signal Generator, Generator

References

Leave a comment

Your email address will not be published. Required fields are marked *