INTRODUCTION

The device is a single-door multifunction standalone access controller or a Wiegand output reader. The operation is very user-friendly, and low-power circuit makes it long service life.

Features

  • Metal case, anti-vandal
  • Waterproof, conforms to IP65
  • Video calling based on WiFi
  • One relay, 1,000 users (990 common + 10 visitors)
  • PIN length: 4-6 digits
  • Card type:125KHz EM Card/13.56MHz Mifare Card
  • Can be used as a Wiegand reader with buzzer output
  • Card block enrollment
  • Tri-<:0lor LED status display
  • Pulse mode, Toggle mode

Specifications 

  • User Capacity 1000
  • Common User 900 (Fingerpint version supports 100 fingerprints)
  • Visitor User 10
  • Operating Voltage 12- 18V DC
  • Working Current ≤150mA
  • Idle Current ≤ 60mA
  • Proximity Card Reader EM/Mifare
  • Radio Technology 125KHz 113.56MHz
  • Read Range 2-6 cm
  • PIN Length 4-6 digits( Keypad verslon only)
  • Wiring Connections: Relay Output, Exit Button, Wiegand Input, Wiegand Output
  • Relay DNE (NO, NC, Common)
  • Adjustable Relay Output 0-99 Seconds (5 seconds default)
  • Time Lock Output Load 2.Amp Maximum
  • Wiegand Interface EM card: Wiegand 26-44 bits input & output.
    • Milare card: Wiegand 26- 44 bits 56blts, 58blts Input & output.
      (Factory default: Wiegand 26 bits for EM card, Wiegand 34 bits for Mifare card)
  • PIN Output 4 bits, 8 bits(ASCII), 10 digits Virtual Number (Factory Default 4 bits)
  • Environment Meets IP65
  • Operating Temperature -40’C-60″C(-40’F-140’F)
    • -30’C-60’C(-22’F-140’F) Fingerprint orly
  • Operating Humidity 0¾RH-92°/oRH
  • Physical Zinc-Alloy
  • Colour Silver & Black
  • Dimensions 142 x 48 x 22mm
  • Unit Weight 315g
  • Shipping Weight 410g

Carton Inventory

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-1

INSTALLATION

  • Remove the back cover from the unit
  • Drill 2 holes(A,C) on lhe wall for lhe screws and one hole for the cable
  • Knock the supplied rubber bungs lo the screw holes(A,C)
  • Fix the back cover firmly on the wall with 4 Hat head screws
  • Thread tl1e cable tl1rough the cable hole(B)
  • Attach the unit to the back cover

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-2

Wiring

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-8

Basic Configure

Enter and Exit Program Mode

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-9

Set Master Code

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-10

Set the Working Mode

Notes: The device has 3 working modes: Standalone Mode, Controller Mode, Wiegand Reader Mode, choose the mode you use. (Factory default is Standalone Mode/controller Mode)ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-11

STANDALONE MODE

The device can work as a Standalone Access Control for a single door. (Facto<y default mode)– 7 7 #

Connection Diagram

Common Power Supply

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-3

Attention:

An install 1 N4004 or equivalent diode is needed when using a common power supply, or the keypad might be damaged. (1 N4004 is included in the packing)

Access Control Power Supply

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-4

Programming
Programming will be wry depending on access configuration. Folk: YN the instructions according to your access configuration.

Notes:

User ID number. Assign a user ID to the access fingerprint card/ PIN in order to track il

The Common User ID:
Fingerprint version:

  • Fingerprint user ID: O-98
  • Card user ID: 100 – 989
  • Master Fingerprint User ID: 99
  • Visitor User ID: 990-999

The other two versions: 

  • PIN/Card User ID: 0-989
  • Visitor User ID: 990-999

IMPORTANT: User IDs do not have to be preceded with any leading zeros. Recording of the User ID is critical. Modifications to the user require the User ID to be available.

  • Proximity Card:
    Proximily Card: 125KHz EM card/13.56MHz Mifare Card
  • PIN: Can be any 4–6 digits except 8888

Add Common Users

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-12

Tips for PIN Security (Only valid for 6-digit PIN):
For higher security, we allow you to hide your correct PIN with other numbers up to a maximum of 10 digits.

Example PIN: 123434
You could use 0(123434) u or”” (123434)
(“•” can be any numbers from 0~9)

Note: This function for the keypad version only

Add Master Fingerprint (By Specified ID: 99, Fingerprint version only)

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-13

Add Visitor Users (Valid for Card/ PIN Users)

(User ID number is 990-999; PIN lengtl1: 4-6 digits except 8888) There are 10 groups of Visitor PIN/ca.rd available; users can specify up to 10 users of usage. After a certain number of times, I.e. 5 times, the PIN/card becomes invalid automatically.

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-14

Change PIN Users (PIN length: 4-6 digits except 8888) (Keypad versior only)

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-15

Delete Users

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-16

Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-17

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-18

Set Access Mode

For multi-user access mode, the interval time of reading can not exceed 5 seconds. or else, the device will exit to standby automatically.

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-19

SetStrike-outAlanm

The strike-out alarm wil engage after 10 failed entry attempts (Factory is OFF).
It can be set to deny access for 10 minutes after engaging or disengaging only after entering a valid FinerprinU card/ PIN or Master code/ fingerprint/ card.

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-20

Set Audible and Visual Response

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-21

Users’ Operation & Reset to Factory Default

  • Open the door: Read valid user fingerprint or user card or input valid user PIN #
  • Remove Alarm: Enter Master Code# or Master Fingerprint/ Card or valid user fingerprint/card / PIN
  • To “‘set to factory default & Add Ma&ter Card: Power off, press the Exit Button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card/ 13.56MHz Mifare Card, the LED will turn into red, means reset to factory default successfully. Of the card reading, it is the Master Card.

Remarks:

  1. If no Master Card added, must press the Exit Button for at least seconds before release.(This will make the previously registered Master Card invalid)
  2. Reset to factory default, the user’s information is stil retained.

Master Fingerprint/ Card Usage (MasterCard is not a default accessory in the box, please add ii by yourself if needed)

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-22

CONTROLLER MODE

The device can work as a Controller, connected with the external Wiegand reader. (Factory default mode) — 7 7 #

Connection Diagram

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-5

Attention: Install a 1 N4004 or equivalent diode is needed when use a common power supply, or the reader migh1 be damaged. (1 N4004 is included in the packing)

Set Wiegand Input Formats

Please set the Wiegand input formats according to the Wiegand output fonnat of the external Reader.

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-23

Programming

  • Basic Programming Is the same as Standalone Mode
  • There are some exceptions for your attention:

The device is connected with an external card Reader

  • If EM/Mifare card reader: users can be added/deleted on either the device or the external reader.
  • If an HID card reader is used, users can only be added/deleted on the external reader.

The device is connected with a Fingerprint Reader

For example:
Connect SF1 as the fingerprint reader to the device.

Slop 1:Addthe Fingerprint (A) on SF1 (Please refer to SF1 manual)
Step 2: Add the same Fingerprint(A) on the device:

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-24

The device is connected with the Keypad Reader
The keypad reader can be 4 Bits, 8 Bits (ASCII), or 10 Bits output functional.
Choose the operation below according to the PIN output format of your reader.

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-25

Remarks mean 4 bits, 8 means 8 bits, 10 means 10-digit virtual number.

Add PIN Users:
To add PIN users, after entering programming mode on the device, PIN(s) can be input on either the device or the external Keypad Reader.

Delete PIN Users: the same way as add users.

WIEGAND READER MODE

The device can work as a Standard Wiegand Reader, connected to the third-party Controller — 7 B #

Connection Diagram

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-6

Notes: 

  • When set into Wiegand ReaQer mode, nearly al settings in Controller Mode will become invalid, and the Yellow wire will be redefined as below:
    • Yellow wire: Buzzer control
  • If you need to connect the Yellow wire:
    • When the input voltage for the Buzzer is low, it will sound.

Set Wiegand Output Fonmats
Please set the Wiegand output formats of the Reader according to the Wiegand input formats of the Controller.

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-26

Note: For connecting the Wiegand controller with 32, 40, 56 bits input, you need to disable parity bits.

ADVANCED APPLICATION

Collection Card Mode
After this mode is turned on, all cards can open the lock. At the same 1ima, the ca.rd is added to the device.

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-27

ATIS-AK-722DW-T-Wi-Fi-Code-Keypad-FIG-7

User Manual 

Documents / Resources

ATIS AK-722DW/T Wi-Fi Code Keypad [pdf] User Manual
AK-722DW, AK-722DT, AK-722DWT Wi-Fi Code Keypad, AK-722DWT, Wi-Fi Code Keypad, Code Keypad

References

Leave a comment

Your email address will not be published. Required fields are marked *