Product Usage Instructions
Basic Functions
The mouse features the following basic functions:
- Left mouse button
- Forward button
- Backspace button
- Right mouse button
- Middle mouse button
- Mouse Scroll
Indicator Lights
The mouse has two indicator lights:
- Mouse indicator
- Dongle indicator
Working Mode Switching
The mouse can switch between Wired and RF modes using the toggle switch.
Hardware Pairing
To pair the mouse with the dongle:
- Connect the dongle to the PC.
- Move the switch to RF mode (gear O) and hold down the left,middle, and right buttons for 5 seconds. The LED indicator will blink Yellow during pairing. Successful pairing is indicated when the Dongle’s indicator lights up blue.5. DPI Setting
DPI settings can be adjusted for sensitivity.
Polling Rate Setting
The polling rate can be adjusted for wired and wireless modes.
LOD Setting
LOD (Lift-off Distance) can be set using the right mouse button.
Motion Sync Setting
The Motion Sync function can be enabled or disabled using the right mouse button.
Debounce Time Setting
Debounce time can be adjusted by holding the Hz switch and clicking the DPI button.
Frequently Asked Questions
Q: How do I switch between wired and RF modes?
A: Use the toggle switch on the mouse to switch between wired and RF modes.
Q: How do I know if the pairing was successful?
A: A successful pairing is indicated when the Dongle’s indicator lights up blue.
Q: How can I adjust the DPI settings?
A: DPI settings can be adjusted for sensitivity levels.
Q: What is LOD setting and how can it be adjusted?
A: LOD (Lift-off Distance) setting can be adjusted using the right mouse button.
Q: What is Motion Sync setting and how can it be controlled?
A: The Motion Sync function can be enabled or disabled using the right mouse button.
Q: How do I adjust the Debounce Time setting?
A: Hold the Hz switch and click the DPI button to switch Debounce Time settings.
Basic function
Indicator light
Working mode switching
Toggle switch,
- Wired mode when moved to the left “X“;
(The wired mode battery disconnection); - RF mode when moved to the right “O“;
Hardware pairing
Procedure:
- Dongle access PC;
- Pull the mouse move switch to the gear “O”, and hold down the “left button + Middle button + right button” for 5 seconds;
- This will enter pairing mode.Once in Pairing mode , the mouse LED indicator will blink Yellow color.
- When Dongle’s indicator lights up “blue”, the pairing is successful;
DPI Setting
Gather Step 1: Press the “DPI” switch to light the OLED, and the OLED will display the current set values;
Gather Step 2: Press the switch again, set the DPI value, at this time OLED will only display the DPI value, other Settings will be hidden;
Gather Step 3: After the setting is complete, wait 1 second, OLED will return to the main interface;
Gather Step 4: Wait another 3 second and the OLED will turn off;
DPI sets the step level
400-800-1600-3200-6400-12800-32000
Back and forth cycle
Default = 800
Polling Rate Setting
Gather Step 1: Press the “Hz” switch to light the OLED, and the OLED will display the current set values;
Gather Step 2: Press the switch again, set the polling rate value, at this time OLED will only display the polling rate value, other Settings will be hidden;
Gather Step 3: After the setting is complete, wait 1 second, OLED will return to the main interface;
Gather Step 4: Wait another 3 second and the OLED will turn off;
Wire mode polling rate sets the step level
125Hz-250Hz-500Hz-1000Hz-2000Hz-4000Hz-8000Hz
Back and forth cycle
Wireless mode polling rate sets the step level
125Hz-250Hz-500Hz-1000Hz-2000Hz-4000Hz-8000HZ
Back and forth cycle
Note:
- Default = 1000
- In 2.4G mode, the HZ key cannot be set when the Dongle is not connected
LOD Setting
Gather Step 1: Press the “Hz” switch to light the OLED, and the OLED will display the current set values;
Gather Step 2: Hold down the “Hz” switch and set the LOD height value by pressing the right mouse button. At this time, OLED will only display the current LOD set value, and other set values will be hidden;
Gather Step 3: After the setting is complete, wait 1 second, OLED will return to the main interface;
Gather Step 4: Wait another 3 second and the OLED will turn off;
LOD sets the step level
0.7mm—1mm—2mm
Back and forth cycle
Default = 1mm
Motion Sync Setting
Gather Step 1: Press the “Hz” switch to light the OLED, and the OLED will display the current set values;
Gather Step 2: Hold down the “Hz” switch and press the right mouse button to enable or disable the “Motion Sync” function. At this point, the OLED will only display the current setvalue, and other set values will be hidden;
Gather Step 3: After the setting is complete, wait 1 second, OLED will return to the main interface;
Gather Step 4: Wait another 3 second and the OLED will turn off;
Motion Sync sets the step level
ON—OFF
Back and forth cycle
Default = ON
Debounce Time Setting
Gather Step 1: Hold the “Hz” switch and click the DPI button to switch Debounce Time. At this time, OLED will only display the current set value, other set values will be hidden;
Gather Step 2: After the setting is complete, wait 1 second, OLED will return to the main interface;
Gather Step 3: Wait another 3 second and the OLED will turn off;
Debounce Time sets the step level
0mS—3mS—5mS—7mS—10mS—12mS
Back and forth cycle
Default = 3mS
Mouse indicator logic
- When turned off: off
- When charging: Red
- When fully charged: Blue
- When battery is low: Flashing Red
- What level of battery is considered low: 30%
- In pairing mode: Flashing Yellow
Dongle indicator logic
- When the mouse is properly connected: Blue
- When the mouse is still for 40 seconds: Off
- Disconnect from the mouse: Off
Note:
8K Dongle LED on and off Settings
- Toggle the LED On/Off by holding down the buttons 1, 2 and 3 for 5 seconds.
Default = LED ON
FCC STATEMENT
Caution:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure condition without restriction.