This installation guide provides simple function information or PLC control. Please read carefully this data sheet and manuals before using products. Especially read precautions then handle the products properly.

Safety Precautions

Meaning of warning and caution label

LS XBL-C21A-Programmable-Logic-Controller-FIG-4 WARNING WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
LS XBL-C21A-Programmable-Logic-Controller-FIG-4 CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

It may also be used to alert against unsafe practices

WARNING
①    Do not contact the terminals while the power is applied.

②    Be sure there are no foreign metallic matters.

③    Do not manipulate the battery(charge, disassemble, hitting, short, soldering).

CAUTION
①    Be sure to check the rated voltage and terminal arrangement before wiring

②    When wiring, tighten the screw of the terminal block with the specified torque range

③    Do not install flammable things in surroundings

④    Do not use the PLC in an environment of direct vibration

⑤    Except for expert service staff, Do not disassemble fix or modify the product

⑥    Use the PLC in an environment that meets the general specifications contained in this datasheet.

⑦    Be sure that external load does not exceed the rating of output module.

⑧    When disposing of PLC and battery, treat it as industrial waste.

Operating Environment

To install, observe the below conditions

No Item Specification Standard
1 Ambient temp. 0 ~ 55℃
2 Storage temp. -25 ~ 70℃
3 Ambient humidity 5 ~ 95%RH,  non-condensing
4 Storage humidity 5 ~ 95%RH,  non-condensing
 

 

 

 

5

 

 

 

Vibration Resistance

Occasional vibration
Frequency Acceleration Amplitude Number  

 

 

IEC 61131-2

5≤f<8.4㎐ 3.5mm 10 times in each direction

for

X, Y, Z

8.4≤f≤150㎐ 9.8㎨(1g)
Continuous vibration
Frequency Acceleration Amplitude
5≤f<8.4㎐ 1.75mm
8.4≤f≤150㎐ 4.9㎨(0.5g)

Applicable Support Software

For system configuration, the following version is necessary.

  1. XBC Series : SU(V1.5 or above), H(V2.4 or above), U(V1.1 or above)
  2. XEC Series : SU(V1.4 or above), H(V1.8 or above), U(V1.1 or above)
  3. XBM Series : S(V3.5 or above), H(V1.0 or above)
  4. XG5000 Software : V4.00 or above

Accessories and Cable Specifications

  • Check the RS-232/485 Connector attached in the module. (XBL-C41A)
  • Check terminal resistance contained in the box. (XBL-C41A)
    • Terminal resistance : 120Ω, 1/2W, allowance 5% (2EA)
  • When using the RS-422 or RS-485 communication channel, twisted pair cable shall be used with consideration of communication distance and speed.
    1. Item : Low Capacitance LAN Interface Cable
    2. Type: LIREV-AMESB
    3. Size : 2P X 22AWG(D/0.254 TA)
    4. Manufacturer : LS Cable Co., Ltd
    5. Electrical characteristics
Items Unit Characteristics Condition
Conductor Resistance Ω/km 59 or less 25℃
Withstanding Voltage (DC) V/1min 500V, 1Min. In air
Insulation Resistance MΩ-km 1,000 or more 25℃
Capacity Pf/M 45 or less 1kHz
Characteristic Impedance 120±12 10MHz

Parts name and Dimension (mm)

This is the front part of the product. Refer to each name when operating the system. For more information, refer to user’s manual

LS XBL-C21A-Programmable-Logic-Controller-FIG-1

LED details

Name Description Status LED Status Description
RUN Cnet operation status On Normal operating
Off Abnormal operation of the Cnet I/F module
 

I/F

Interface status with CPU On Interface error with the CPU module
Off Communication module initialization error
Blinks Normal operating
TX During frame

transmission

On During frame transmission
Off Frame transmission completed
RX During frame

receiving

On During frame receiving
Off Frame receiving completed
ERR Displays fame error On Frame error
Off Normal frame

Installing / Removing Modules

Here describes the method to attach each module to the base or remove it.

  1. Installing module
    1. Eliminate the Extension Cover at the product.
    2. Push the product and connect it in agreement with Hook For Fixation of four edges and Hook\ For Connection.
    3. After connection, push down the Hook For Fixation and fix it completely.
  2. Removing module
    1. Push up the Hook For Disconnection, and then detach the product with two hands. (Do not detach the product by force)

LS XBL-C21A-Programmable-Logic-Controller-FIG-2Wiring

Wiring for Communication
RS-232C connector (modem connection)

LS XBL-C21A-Programmable-Logic-Controller-FIG-5

For more information about wiring, refer to user manual

Warranty

  • The warranty period is 36 months from the date of manufacture.
  • The initial diagnosis of faults should be conducted by the user. However, upon request, LS ELECTRIC or its representative(s) can undertake this task for a fee. If the cause of the fault is found to be the responsibility of LS ELECTRIC, this service will be free of charge.
  • Exclusions from warranty
    1. Replacement of consumable and life-limited parts (e.g. relays, fuses, capacitors, batteries, LCDs, etc.)
    2. Failures or damages caused by improper conditions or handling outside those specified in the user manual
    3. Failures caused by external factors unrelated to the product
    4. Failures caused by modifications without LS ELECTRIC’s consent
    5. Use of the product in unintended ways
    6. Failures that cannot be predicted/solved by current scientific technology at the time of manufacture
    7. Failures due to external factors such as fire, abnormal voltage, or natural disasters
    8. Other cases for which LS ELECTRIC is not responsible
  • For detailed warranty information, please refer to the user’s manual.
  • The content of the installation guide is subject to change without notice for product performance improvement.

contact

LS ELECTRIC Co., Ltd www.ls-electric.com 10310000734 V4.6 (2024.10)LS XBL-C21A-Programmable-Logic-Controller-FIG-6

  • E-mail: automation@ls-electric.com
  • Headquarters/Seoul Office Tel: 82-2-2034-4033,4888,4703
  • LS ELECTRIC Shanghai Office (China)
  • Tel: 86-21-5237-9977
  • LS ELECTRIC (Wuxi) Co., Ltd. (Wuxi, China)
  • Tel: 86-510-6851-6666
  • LS-ELECTRIC Vietnam Co., Ltd. (Hanoi, Vietnam)
  • Tel: 84-93-631-4099
  • LS ELECTRIC Middle East FZE (Dubai, U.A.E.)
  • Tel: 971-4-886-5360
  • LS ELECTRIC Europe B.V. (Hoofddorf, Netherlands)
  • Tel: 31-20-654-1424
  • LS ELECTRIC Japan Co., Ltd. (Tokyo, Japan)
  • Tel: 81-3-6268-8241
  • LS ELECTRIC America Inc. (Chicago, USA)
  • Tel: 1-800-891-2941
  • Factory: 56, Samseong 4-gil, Mokcheon-eup, Dongnam-gu, Cheonan-si, Chungcheongnamdo, 31226, Korea

LS XBL-C21A-Programmable-Logic-Controller-FIG-3

Documents / Resources

LS XBL-C21A Programmable Logic Controller [pdf] Instruction Manual
XBL-C21A, C41A, XBL-C21A Programmable Logic Controller, XBL-C21A, Programmable Logic Controller, Logic Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *