Laserliner SmartCross-Laser GX Plus Set
Completely read through the operating instructions, the II Warranty and Additional Information II booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain.These documents must be kept in a safe place and passed on together with the product.
Intended use
This cross-line laser projects a green laser cross and is intended for aligning horizontals, verticals and slopes. Optical signals indicate when the unit is outside its self-levelling range. The product has an integral hand-held receiver mode and a 1/411 tripod connection.
General safety instructions
- The device must only be used in accordance with its intendedpurpose and within the scope of the specifications.
- The measuring tools and accessories are not toys. Keep out of reach of children.
- Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
- Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
- The device must no longer be used if one or more of its functions fail, the battery charge is weak, or the housing has been damaged.
Safety instructions
Using class 2 lasers
IEC 60825-1 :2014, EN 60825-1 :2014/A 11 :2021 EN 50689-1 :2021
- Attention: Do not look into the direct or reflected beam.
- Do not point the laser beam towards persons.
- If a person’s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
- Under no circumstances should optical instruments (magnifying glass, microscope, binoculars) be used to look at the laser beam or reflections.
- Do not use the laser at eye level (1 .40 … 1.90 m)
- Reflective, specular or shiny surfaces must be covered whilst laser devices are in operation.
- In public areas shield off the laser beam with barriers and partitions wherever possible and identify the laser area with warning signs.
Safety instructions
Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU.
- Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
When transporting always switch off all lasers, secure pendulum and push the slide switch (2) to the left.
Special product features
Automatic alignment of the device with a magnetically dampened pendulum system.
The device is brought into initial position and aligns itself autonomously.Transport LOCK: The device is protected with a pendelum lock during transport.
GRX-READY technology enables line lasers to be used even in unfavourable light conditions. The laser lines pulsate at a high frequency and this can be picked up by special laser receiversover long distances.
Green laser technology
Devices with PowerGreen technology feature bright green high-performance diodes that allow very good visibility of laser lines at great distances, on dark surfaces and in bright ambient light conditions.
Approx. 6 times brighter than a typical red laser with 630 – 660 nm.
PRODUCT OVERVIEW
- Laser output windows
- Slide switch
- a ON
- b OFF/ transport lock/ slope mode
- Battery compartment (bottom)
- 1/4″ tripod threads (bottom)
- LED levelling
red: levelling off
green: levelling on - ON/OFF button;
Hand receiver mode on / off - LED hand receiver mode
Inserting batteries
Open the battery compartment and insert batteries (2 x 1,5V LR06 (AA)) according to the symbols. Be sure to pay attention to polarity.
Horizontal and vertical levelling
Release the transport restraint, push the slide switch (2) to the right. The laser lines can be switched individually with the selection button.
The transport restraint must be released for horizontal and vertical levelling. The LED (5) shows a permanent green light. The laser lines flash as soon as the device is outside the automatic levelling range of 4°. Position the device such that it is within the levelling range. The light of the laser linesis constant again.
Slope mode
Do not release transport restraint, push slide switch (2) to the left. Sloping planes can now be measured. This mode cannot be used to perform horizontal or vertical levelling as the laser lines are no longer aligned automatically. The laser lines flash green.
Hand receiver mode
Optional: Working with the laser receiver GRX
Use an GRX laser receiver (optional) to carry out levelling at great distances or when the laser lines are no longer visible. To work with a laser receiver, switch the line laser to hand-held receiver mode by keeping button 6 (handheld receiver mode on/ off) pressed. The laser lines will now pulsate with high frequency, making the laser lines darker. The laser receiver can detect these pulsating laser lines.
Observe the laser receiver’s operating instructions for line lasers.
Preparing the calibration check
It is possible for you to check the calibration of the laser. To do this, position the device midway between 2 walls, which must be at least 5 metres apart. Switch the device on (LASER CROSS ON). The best calibration results are achieved if the device is mounted on a tripod.
- Mark point A1 on the wall.
- Turn the device through 180° and mark point A2. You now have a horizontal reference between points A1 and A2.
Performing the calibration check - Position the device as near as possible to the wall at the height of point A 1.
- Turn the device through 180° and mark point A3.
The difference between points A2 and A3 is the tolerance.
When A2 and A3 are more than 0.3 mm/ m apart, an adjustment is necessary. Contact your authorised dealer or else the UMAREX-LASERLINER Service Department.
Checking the vertical line
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on the wall, making sure that the bob can swing freely. Switch on the device and align the vertical laser to the plumb line. The precision is within the specified tolerance if the deviation between the laser line and the plumb line is not greater than ± 1.5 mm.
Checking the horizontal line
Position the device about 5 m from a wall and switch on the cross laser. Mark point B on the wall. Turn the laser cross approx. 2.5 m to the right and mark point C. Check whether
the horizontal line from point C is level with point B to within ± 1.5 mm. Repeat the process by turning the laser to the left.
Regularly check the calibration before use, after transport and after extended periods of storage.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
Calibration
The measuring device should be calibrated and tested on a regular basis to ensure it is accurate and working properly. We recommend the measuring device is calibrated every
1 – 2 years. If necessary, contact your distributor or the UMAREX-LASERLINER service department.
Technical data
- Self-levelling range ± 40
- Accuracy ± 0.3 mm Im
- Levelling automatic
- Visibility (typical)* 40 m
- Laser wavelength 515 nm
- Laser class 2 / < 1 mW (EN IEC 60825-1 :2014/A 11 :2021)
- Power supply 2 x 1,5V LR06 (AA)
- Operating time approx. 5 hours -10°C … 50°C, max. humidity 80% rH,
- Operating conditions no condensation, max. working altitude 4000 m above sea level
- Storage conditions -20°C … 70°C, max. humidity 85% rH
- Dimensions (W x H x D) 84 x 76 x 62 mm
- Weight 276 g (incl. batteries)
* at max. 300 lux
EU and UK directives and disposal
- This device complies with all necessary standards for the free movement of goods within the EU and the UK.
- This product, including accessories and packaging, is an electrical appliance that must be recycled in an environmentally appropriate manner in accordance with European and UK directives on waste electrical and electronic equipment, batteries and packaging, in order to recover valuable raw materials. Electrical devices, batteries and packaging do not belong in household waste. Users are obliged by law to surrender used batteries or battery packs to a public collection point, to sales outlets, or to technical customer services, free of charge. Remove the battery from the device without damaging it using standard commercial tools: arrange separate collection before returning the device for disposal. Please do not hesitate to contact the UMAREX-LASERLINER service department if you have any queries regarding removing the battery. Look for information on local disposal facilities and note the relevant disposal and safety information at the collection points.
- Further safety and supplementary notices at https://packd.li/11/AMU/in
SmartCross-Laser GX
Umarex GmbH & Co. KG
– Laserliner – Gut Nierhof 2 59757 Arnsberg, Germany
Tel.: +49 2932 9004-0
info@laserliner.com
www.laserliner.com
MADE IN PRC
Rev24W03
Documents / Resources
![]() |