VALORE AC152 Multi-Function Smart Digital Multimeter
Thank you for purchasing the Valore Multi-Function Smart Digital Multimeter (AC152).
- Non-contact AC voltage detection
- Automatic range measurement
- Overload protection
Important: Please read the user manual thoroughly before using your digital multimter.
Specifications:
Voltage DC
- Range: 500V
- Resolution: 0.1V
- Accuracy: ± (0.8% + 3 counts)
Voltage AC
- Range: 500V
- Resolution: 0.1V
- Accuracy: ± (1.2% + 5 counts)
Resistance
- Range: 6000Ω
- Resolution: 1Ω
- Accuracy: ± (1.2% + 3 counts)
Frequency
- Range: 1000Hz
- Resolution: 0.1Hz
- Accuracy: ± (1.0% + 5 counts)
- Auto power off time: About 5 minutes
- Max display: 2000
- Battery capacity: 1.5V x 2 AAA battery (not included)
- Dimensions (L x W x D): 160 x 28 x 32mm
- Weight: 69g
Package Contents
- 2-way connectivity wireless keyboard with touchpad
- Wireless receiver
UNDERSTANDING THE PRODUCT
- V~Alert sensor area
- Display
- Power switch
- High sensitivity mode/ Flashlight switch
- Voltage signal indicator 6. Input terminal
START USING THE DIGITAL MULTIMETER
Power switch
Switch mode, flashlight switch button:long press to switch mode, short press to turn on the flashlight.
: “COM” Input terminal
: “INPUT” Input terminal
Symbol |
Elaborate on |
![]() |
Voltage AC |
![]() |
Voltage DC |
![]() |
Continuity |
![]() |
Battery is low and should be changed |
AUTO |
Automatic range measurement mode |
![]() |
Auto power off function indication |
ll’~Alert |
Non-contact AC voltage detection/NCV |
![]() |
Non-contact AC voltage detection high sensitivity mode |
V |
Voltage unit: volt |
Hz |
Hertz, Kilohertz, Megahertz |
![]() |
Resistance unit: Ohm, kilohm, mega ohm |
Technical index
Accuracy
Accuracy applies within one year of calibration. Reference conditions: environmental temperature 18 °C to 28 °C, relative humidity is not greater than 80.
- Voltage DC
Range Resolution Accuracy soov 0.1V ±(0.8%+3counts) Sensitivity: minimum O.SV DC voltage Input impedance: lMO
Maximum input voltage : SOOV DC&AC ( RMS) - Voltage AC
Range Resolution Accuracy soov 0.1V ±(1.2%+ Scounts) Sensitivity: minimum 1 V DC voltage Input impedance: lMO
Maximum input voltage : SOOV DC&AC ( RMS)
Frequency range: 50Hz~60Hz, true RMS response. - Resistance
Range Resolution Accuracy 6000Ω 1Ω ±(1.2% +3counts) Overload protection : SOOV DC or AC ( RMS )
- Frequency
Range Resolution Accuracy lOOOHz O.lHz ±(1.0%+Scounts) Frequency range: 40Hz~ lOOOHz.
- Measure Continuity
Function Accuracy If the resistance is < 300, the continuity beeper sounds. Overload protection : SOOV DC or AC ( RMS )
- V~Alert
Range Explanation Low- r ange Green voltage signal indicator.The screen displays 1/3 analog bar,the buzzer sounds a slow alarm . Mid-range Yellow voltage signal indicator.The screen displays 2/3 analog bar,the buzzer sounds a quick alarm. High-range Red voltage signal indicator.The screen displays full analog bar,the buzzer sounds a very loud alarm . - High sensitivity mode
Range Explanation Low-range Green voltage signal indicator.The screen displays 1/3 analog bar,the buzzer sounds a slow alarm . Mid-range Yellow voltage signal indicator.The screen displays 2/3 analog bar,the buzzer sounds a quick alarm . High-range Red voltage signal indicator.The screen displays full analog bar,the buzzer sounds a very loud alarm . Voltage range: 6V~l000V AC
Operation instruction
Voltage DC or AC/Frequency/Resistance/Measure Continuity
- Insert the red test lead into the “INPUT” terminal, black test lead into the “COM” terminal.
- Connect the test leads in parallel to the circuit,power supply,tested
resistor .The meter automatically Identify whether it is AC voltage,DC voltage or resistance,and shows the frequency on the screen. - When resistance is less than 30Ω, the buzzer sounds.
- When measuring DC voltage, it can also shows the voltage polarity of the red test lead.
- Read the measurement results from the display.
Voltage DC
Voltage AC Frequency
Resistance
Measure Continuity
Warning:
- Do not input voltages higher than 500V, showing higher voltage are possible, but it may destory the meter.
- When measuring high voltage, be careful to avoid electric shock.
- Disconnect the test leads from the circuit when completed measurement.
Socket live wire distinguish/Non-contact AC voltage detection
- Press the power button.
- Put the sensor head into the power outlet or near the electrified lead wire, and when the tester detects the AC voltage signal, the voltage signal flicks the signal,the bar value of the meter screen lights up,and the test is based on the intensity of the signal detected, lighting the corresponding signal strengt indicator lights (high, medium, low), and the buzzer emits different frequencies of alarm sound.
- Push the inductive head of the tester close to the wire, plug the probe into the jack.The tester detects that one of the strong induced signal is live wire, and the weak or non-sensing signal of the induction signal is neutral wire.
- Long press the blue button for 2 seconds to switch to high sensitivity mode In this mode it can detect AC voltage in the range of 6V ~ 1000V
Socket live wire distinguish
Non-contact AC voltage detection high sensitivity mode
Warning:
- Non-contact AC voltage and live wire detection operations may be influenced by the socket design, insulation thickness and class .. Even without indication, the voltage may still exist. Do not use non-contact voltage detector to determine whether the voltage existance.
- When input voltage, the non-contact voltage sensing indicator may light on because of the existance of induced voltage
- Outside environment (such as flash, motor, etc.) may influence the non-contact voltage detection.
TECHNICAL SUPPORT & WARRANTY
- For Technical Support, email us at v.info@valore.sg.
- For Warranty Registration, visit www.valore.sg.
Cautions:
Read all the instructions and warnings carefully prior to using this product.
- Do not store the product in a high temperature environment.
- Do not place the product near a fire or other excessively hot environments.
- Do not expose the product to moisture or submerge it in liquid. Keep product dry at all times.
- Do not attempt to charge the product using any other method or connection other than the product’s provided charging cable.
- Do not disassemble this product or attempt to repair or modify it in any manner.
- Battery usage by children should be supervised
- Be cautious of excessive drops, bumps, abrasions or other impacts to this product. If there is any damage to the product such as dents, punctures, tears, deformities or corrosion, stop using the product and contact us immediately via email at v.info@valore.sg, or return this product to the store where you have purchased it from.
- If the product produces an abnormal smell, high temperature (low temperature during normal use), discolours or changes shape abnormally, stop using the product and contact us immediately via email at v.info@valore.sg.
DISCLAIMER & TRADEMARKS
All information, trademarks, logos, graphics, and images (“Materials”) provided on this user manual are copyrighted or trademarked and are the property of Valore Lifestyle Pte Ltd. Any unauthorized use of any material contained on the instruction manual may violate copyright laws, trademark laws, laws of privacy and communications statutes.The trademarks, service marks and logos used and displayed in the Materials are registered and unregistered
trademarks and service marks of Valore and others. All other registered and unregistered company names,product names and marks mentioned herein the (“Materials”) are the property of their respective owners and may be trademarks or registered trademarks.
Inspired by Valore Singapore For full range of Valore products visit www.valore.sg
Documents / Resources
![]() |
VALORE AC152 Multi-Function Smart Digital Multimeter [pdf] User Manual AC152, Multi-Function Smart Digital Multimeter |