Tektronix TPP0500B Probe Oscilloscope
Specifications
- Bandwidth: 1000 MHz, 500 MHz, 250 MHz, 50 MHz, 100 MHz, 200 MHz, 6 MHz, 15 MHz, 300 MHz
- Attenuation: 10X, 2X, 1X, 10X
- Input Impedance: 10 MΩ || 3.9 pF, 2 MΩ || 12.7 pF, 1 MΩ || 110 pF, 10 MΩ || 17 pF, 1 MΩ || 100 pF, 10 MΩ || 11 pF, 10 MΩ || 8 pF, 1 MΩ || 110 pF, 10 MΩ || 17 pF
- Maximum Voltage: 300 Vrms (CAT II), 150 Vrms (CAT II)
- Interface: TekVPI w/Key, BNC, TekProbe LEVEL1
- Compensation Range: Varies by model
Passive Probes Overview
Passive voltage probes are general-purpose probing solutions that come standard with most oscilloscopes. They offer a low-cost option with wide dynamic range suitable for various applications. Tektronix has introduced a new class of passive probes that excel in performance within this category.
Tektronix Passive Probe Solutions
The new class of passive probe solutions from Tektronix offers various models with different specifications. Some of the key models include TPP1000, TPP0500B, TPP0502, TPP0250, TPP0051, TPP0100, TPP0101, TPP0200, and more.
Key Specifications
Ensure you select the appropriate probe based on the required bandwidth, attenuation, input impedance, and maximum voltage rating. The interface compatibility is also crucial for proper integration with your oscilloscope.
FAQs
What are the key features of Tektronix passive probes?
The Tektronix passive probes offer a wide range of bandwidth options, attenuation settings, and maximum voltage ratings suitable for various testing scenarios. They are designed for compatibility with TekVPI w/Key and BNC interfaces.
Which models of oscilloscopes are compatible with Tektronix passive probes?
Tektronix passive probes are compatible with a range of Tektronix oscilloscope models including TDS1000/2000, TBS1000 TPS2000 THS3000, MSO/DPO2000 MSO/DPO3000 MSO/DPO4000 series, DPO7000C series, and more. Refer to the user manual for specificcompatibility details.
“`
Some probes require an external power supply (1103) when used with the TDS3000 series 2. When using with MSO / DPO2000 series, a dedicated AC adapter (119-8726-00) and a power cable (161-0342-00) are required. 3. When using with MSO / DPO3000 series, depending on the probe you may need a separate AC adapter (119-8726-00) and a power cable (161-0342-00). 4. When using with MSO / DPO5000 series, separate AC adapter (119-8726-00) and power cable (161-0342-00) may be required depending on the probe model and number. 5. When using with TBS2000 and MDO3000 series, the total power draw capacity can not exceed the maximum power supply capacity of the oscilloscope, see here for more information. 6.
Readout does not function in the TBS2000 series.
Passive voltage probes ship standard with most oscilloscopes and provide a low cost, general purpose probing solution. Generally, these probes lack the performance of an active voltage probe but provide the ruggedness and wide dynamic range suitable for visualizing signals over a broad range of applications. Tektronix has released a new class of passive probes that redefine performance in the passive probe product category.
Tektronix new class of passive probe solutions offer
· Best-in-class bandwidth up to 1 GHz
· Best-in-class input capacitance as low as 3.9 pF which minimizes probe loading effects
· Best-in-class input capacitance which minimizes performance loss when long ground leads are attached
· Automated probe compensation eliminating the need for the compensation screwdriver
10X
10 M || 11 pF
Maximum Voltage 300 Vrms (CAT II) 300 Vrms (CAT II) 300 Vrms (CAT II) 300 Vrms (CAT II) 300 Vrms (CAT II) 300 Vrms (CAT II) 300 Vrms (CAT II) 300 Vrms (CAT II) 300 Vrms (CAT II) 150 Vrms (CAT II), 300 Vrms (CAT II) 150 Vrms (CAT II), 300 Vrms (CAT II)
300 Vrms (CAT II)
300 Vrms (CAT II)
300 Vrms (CAT II)
300 Vrms (CAT II)
300 Vrms (CAT II)
Interface
TekVPI w/Key TekVPI w/Key TekVPI w/Key TekVPI w/Key
BNC BNC BNC BNC BNC
BNC
BNC
TekProbe LEVEL1 TekProbe LEVEL1
BNC TekProbe LEVEL1
BNC
Compensation Range
— — — 1525 pF 818 pF 1525 pF 818 pF 1525 pF 1525 pF
1025 pF
1525 pF
818 pF —
1015 pF
LEARN MORE
TPP1000 / TPP0500B
TPP0200 / TPP0100
P6139B
3
PPAASSSSIVIVE E
ACTIVE
POWER RAIL
DIFFERENTIAL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPTICAL
Passive Probes Accessories
Hook Tip 013-0362-xx
STANDARD ACCESSORIES
Ground Springs 016-2028-xx (long, 2 ea.) 016-2034-xx (short, 2 ea.)
Ground Lead, with Alligator Clip 196-3521-x
Color Bands 016-0633-xx (5 pairs)
TIP CARTRIDGES
TPP1000 206-0610-xx (rigid tip) 206-0611-xx (pogo tip)
TPP1000, TPP0502 Shielded MMCX tip mates directly
with MMCX connector
TPP1000 only 206-0663-xx
TPP0502 only 206-0666-xx
Micro-Hook Tip 013-0362-xx
Universal IC Cap 013-0366-xx
Insulator Sleeve 342-1194-xx
TPP1000, TPP0500, TPP0502
Adjustment Tool 003-1433-xx
204-1226-xx TPP0500B, TPP0250,
P6139B, P5050B
TPP0500B, TPP0250 206-0649-xx (rigid tip) 206-0650-xx (pogo tip)
TPP0502 206-0641-xx (rigid tip) 206-0642-xx (pogo tip)
P6139B 206-0635-xx (rigid tip)
P5050B 206-0636-xx (rigid tip)
MMCX to Square Pin Adapters
131-9717-xx (0.1 inch – blue) 131-9677-xx
(0.062 inch white)
OPTIONAL ACCESSORIES
Electrical Y-Lead 196-3434-xx (square pin on
0.1 in. centers)
MicroCKT Test Tip 206-0569-xx
Ground Lead, 6 inch Clip-On 196-3198-xx
Rigid/Pogo Probe Tip Adapters
013-0367-xx (tip to BNC) 016-2016-xx (PCB Test Point)
131-4210-xx (Chassis-Mount TP)
DUT Interface Pin Kit 0.018 inch round solder-in pins
020-3169-xx (qty 20)
Ground Lead, 12 inch Alligator
196-3512-xx
Adapts MMCX tips to square pins at 0.1 in. or
0.062 in. centers.
Solder-Aide for Pin Kit Holds 0.018 inch pins 0.062 inch apart for soldering on
0402 SMT parts
Probe Tip Tripod 352-1170-xx (qty. 2)
4
PASSIVE
AACCTTIIVVEE
POWER RAIL
DIFFERENTIAL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
Active Probes Low Voltage Single-ended
ISOLATED
OPTICAL
A low voltage single-ended probe is typically used for measuring high-speed, ground referenced signals up to 12 V. These low voltage probes are the best choice for making measurements on high impedance, high frequency circuit elements which require minimal probe loading. Users should select probes with a low input capacitance specification (1 pF) to minimize the probe’s loading effect on the circuit. A probe with lower input capacitance will offer higher input impedance at higher frequencies.
Tektronix Low Voltage Single-ended Probe solutions offer:
· Bandwidths up to 4 GHz
· Very high input impedance with low input capacitance (<1 pF)
· Most extensive set of probe accessories for optimum measurement performance
· The TAP1500L is equipped with a 7 m cable; Ideal for Flying Probe Testers
Model
Bandwidth Attenuation
Input Impedance
Dynamic Range
Offset Range
Maximum Non-Destruct
Voltage
Interface
TAP4000
4 GHz
10X
40 k || 0.8 pF ±4 V
±10 V
±30 V
TekVPI
TAP3500 3.5 GHz
10X
40 k || 0.8 pF ±4 V
±10 V
±30 V
TekVPI
TAP2500 2.5 GHz
10X
40 k || 0.8 pF ±4 V
±10 V
±30 V
TekVPI
TAP1500 1.5 GHz
10X
1 M || 1 pF
±8 V
±10 V ±25 V(DC + PkAC) TekVPI
TAP1500L 1.5 GHz
10X
1 M || 1 pF
±8 V
±10 V ±25 V(DC + PkAC) TekVPI
P6243
1 GHz
10X
1 M || 1 pF
±8 V
N/A
±15 V(DC + PkAC)
TekProbe LVL2
P6245
1.5 GHz
10X
1 M || 1 pF
±8 V
±10 V
±15 V(DC + PkAC)
TekProbe LVL2
LEARN MORE
TAPX000
TAP1500L (7 m cable)
P6243/P6245
5
PASSIVE
ACTIVE
POPWOWEERRRRAAIILL
Power Rail Probes
DIFFERENTIAL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPTICAL
The TPR1000 and TPR4000 probes provide a low noise, large offset range solution for measurement of ripple on DC power rails ranging from 60 to +60 VDC. Tektronix’s power rail probes offer industry leading low noise and high offset range required to measure AC ripple between 200 V p-p and 800 mV p-p at up to 4 GHz.
Key Specs:
· <300 V p-p noise on 6 Series MSO (20 MHz BW Limit)
· <1 mV p-p noise on 6 Series MSO (Full Bandwidth)
· ±60 V offset range
· Offset setting error: ±2 mV max, ±0.4 V typical
Model TPR4000 TPR1000
Bandwidth 4 GHz 1 GHz
Attenuation 1.25X 1.25X
Input Impedance
50 k DC 10 kHz, 50 AC > 100 kHz
50 k DC 10 kHz, 50 AC > 100 kHz
Dynamic Range
±1 V
±1 V
Offset Range
±60 V
Interface TekVPI
±60 V
TekVPI
LEARN MORE
6
PASSIVE
ACTIVE
POPWOWEERRRRAAIILL
DIFFERENTIAL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPTICAL
Power Rail Probes Accessory Kits
1.3m SMA to MMCX Cable 4 GHz
STANDARD ACCESSORIES (TPR4KIT KIT)
1.3m SMA to SMA Cable – 4 GHz MMCX to U.FL adapter – 2 GHz
MMCX to square-pin adapter – 1 GHz
TPR4KITHT KIT
2m SMA to MMCX High Temp Cable 4 GHz
Solder-Aide for Pin Kit
DUT Interface Pin Kit 1 GHz
TPR4SIACOAX: MMCX to micro-coax 4 GHz (set of 3)
TPR4SIAFLEX: MMCX to performance solder tip
4 GHz (set of 3)
TPR4SIACOAX: MMCX to micro-coax 4 GHz (set of 3)
TPR4SIAFLEX: MMCX to performance solder tip
4 GHz (set of 3)
MMCX to U.FL adapter 2 GHz MMCX to U.FL adapter 2 GHz MMCX to U.FL adapter 2 GHz
Blade ground
TPRBRWSR1G KIT
SMT Clip
SMA browser 1 GHz
Spring ground
Rigid browser pin 1 GHz
Browser to square-pins 1 GHz
TPR4SIAFLEX KIT
TPR4SIAFLEX: MMCX to performance solder tip 4GHz (set of 3)
TPR4SIACOAX KIT
TPR4SIACOAX: MMCX to micro-coax 4 GHz (set of 3)
Alligator ground
Pogo browser pin 1 GHz
7
PASSIVE
ACTIVE
POWER RAIL
DIDFIFFFEERREENNTTIIAALL
CURRENT
HIGH VOLTAGE
Differential Probes Low Voltage
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPTICAL
Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential probe ensures that you see every possible detail.
Model
Bandwidth
TDP4000
4 GHz
TDP3500 3.5 GHz
TDP1500
1.5 GHz
TDP1000
1 GHz
TDP0500 500 MHz
P6248
>1.5 GHz
P6247
>1 GHz
ADA400A
>1 MHz
Attenuation
Input Impedance
Differential Input Voltage
Operating Window
Offset Range
Interface
5X
100 k|| 0.3 pF
±2 V
±15 V (DC + pk AC)
±1 V
TekVPI
5X 1X, 10X
100 k|| 0.3 pF 200 k|| 1 pF
±2 V
1X:±0.85 10X: ±8.5 V
±15 V (DC + pk AC)
±25 V (DC + pk AC)
±1 V ±7.0 V
TekVPI TekVPI
5X / 50X
1 M || 1 pF
50X: ±42 V 5X: ±4.2 V
±42 V (DC + pk AC)
30 Vrms
±42 V
TekVPI
5X / 50X
1 M || 1 pF
50X: ±42 V 5X: ±4.2 V
±42 V (DC + pk AC)
30 Vrms
±42 V
TekVPI
1X, 10X 1X, 10X
200 k ||<1 pF 200 k ||<1 pF
1X:±0.85 10X: ±8.5 V
1X:±0.85 10X: ±8.5 V
±7.0 V ±7.0 V
depends on scope
depends on scope
TekProbeLVL2 TekProbeLVL2
.1X – 100X
1 M || ~ 55 pF
.1-80 V**
±10 to ±40 V**
±1 to ±40 V** TekProbeLVL2
LEARN MORE
TDP3500/TDP4000
TDP1500
TDP0500
P6247/P6248
ADA400A
8
PASSIVE
ACTIVE
POWER RAIL
DIDFIFFFEERREENNTTIIAALL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
Differential Probes – Low Voltage – TDP0500, TDP1000 & TDP1500 Accessories
ISOLATED
OPTICAL
Straight Pins
Reorder: 016-1891-XX
MicroCKT Test Tip
Reorder: 206-0569-XX
Usable bandwidth <1.5 GHz Typical rise time <350 ps Connection type PCB, Vias, & ICs
Usable bandwidth <100 MHz Typical rise time <3.5 ns Connection type Leaded components
Use the MicroCKT test tips to access dense circuitry and IC leads spaced down to 10 mil-centers.
Y-Lead Adapter
Reorder: 196-3434-XX
Usable bandwidth <100 MHz
Typical rise time <3.5 ns
Connection type 0.025″ Square Pin
Use the Y-lead adapter to extend the reach of the probe and to connect to 0.025 inch square pins spaced as far as 1.5 inches apart. Use with Square pin adapter.
Longhorn Adapter
Reorder: 016-1884-XX
IC Micro-Grabber
Reorder: SMK4
Usable bandwidth <1.5 GHz Typical rise time <233 ps Tip spacing 10 mils to .35 Inches Connection type PCB, Vias, & ICs
Usable bandwidth <100 MHz Typical rise time <3.5 ns Connection type Leaded components
Use the IC Micro-Grabber to probe the leads on integrated circuits that are surface-mounted.
1″ Solder Down Adapter
Resistor Kit: 020-2506-XX
Usable bandwidth >1 GHz
Typical rise time <233 ps
Tip spacing 10 mils to .35 Inches
Connection type 0.025″ Square Pin
3″ Solder Down Adapter
Resistor Kit: 196-3505-xx
3″ Ground Lead
Usable bandwidth <600 MHz Typical rise time <265 ps Tip spacing 10 mils to .35 Inches Connection type Solder in
Color Bands
Reorder: 196-3465-XX
Reorder: 196-3465-XX
9
PASSIVE
ACTIVE
POWER RAIL
DIDFIFFFEERREENNTTIIAALL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
Differential Probes – Low Voltage – TDP3500 & TDP4000 Accessories
ISOLATED
OPTICAL
Variable Spacing Adapter
Reorder: 016-1885-XX
Usable bandwidth Up to 4 GHz
Typical rise time <110 ps
Tip spacing .020 to .180 inches
Connection type PCB, Vias, & ICs
TwinFootTM Adapter
Reorder: 016-1785-XX
Connection type SMT components
Use the TwinFoot adapter to probe two adjacent leads on a surface-mount integrated circuit. Use with Solder-in Adapter.
Square Pin Adapter
Reorder: 016-1884-XX
Usable bandwidth <3.5 GHz
Typical rise time <120 ps
Connection type .0.025″ Square Pin
Use the square pin adapter to connect the probe to other accessories, such as the Y-lead adapter.
Y-Lead Adapter
Reorder: 196-3434-XX
Usable bandwidth <100 MHz
Typical rise time <3.5 ns
Connection type 0.025″ Square Pin
Use the Y-lead adapter to extend the reach of the probe and to connect to 0.025 inch square pins spaced as far as 1.5 inches apart. Use with Square pin adapter.
IC Micro-Grabber
Reorder: SMK4
Usable bandwidth <100 MHz
Typical rise time <3.5 ns
Connection type Leaded components
Use the IC Micro-Grabber to probe the leads on integrated circuits that are surface-mounted.
MicroCKT Test Tip
Reorder: 206-0569-XX
Usable bandwidth: <100 MHz Typical rise time: <3.5 ns Connection type: Leaded components
Use the MicroCKT test tips to access dense circuitry and IC leads spaced down to 10 mil-centers.
Solder in Adapter + Resistor Kit
Solder in Kit: 020-2505-XX
Usable bandwidth: Up to 4.3 GHz
Solder in adapter: 016-1296-XX Typical rise time: Down to 124 ps
Resistor Kit: 020-2506-XX
Connection type: Solder in
Use the solder-in adapter with the resistors and wires in the kit to create soldered test points to your circuit.
3″ Ground Lead
Reorder: 196-3465-XX
Color Bands
Reorder: 196-3465-XX
10
PASSIVE
ACTIVE
POWER RAIL
DIDFIFFFEERREENNTTIIAALL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPTICAL
TriModeTM Probes – Low Voltage Differential & Single-ended
TriModeTM architecture streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection.
P7600
P7700
P7500
TDP7700
Model
P7633 P7625 P7720 P7716 P7713 P7708
P7520A
Bandwidth
33 GHz 25 GHz 20 GHz 16 GHz 13 GHz 8 GHz
>20 GHz
P7516
16 GHz
P7513A
>13 GHz
P7508
8 GHz
P7506
6 GHz
P7504
TDP7708 TDP7706 TDP7704
4 GHz
8 GHz 6 GHz 4 GHz
Attenuation .25X -20X .25X -20X
5X, 12X 5X, 12X 5X, 12X 5X, 12X 5X, 12X 5X, 12X
Input Impedance
Differential Input Voltage
Operating Window
Offset Range
50 / 225
2 V , 10 V
±4 , ±5
±4
50 / 225
2 V , 10 V
±4 , ±5
±4
See TekFlex Accessory Performance Table
See TekFlex Accessory Performance Table
See TekFlex Accessory Performance Table
See TekFlex Accessory Performance Table
100 k 100 k
5X: ±0.625 V 12.5X: ±1.6 V
5X: ±0.625 V 12.5X: ±1.6 V
+3.7 to 2.0 V
+4.0 to 2.0 V
2.5 to 1.5 V 2.5 to 1.5 V
100 k 100 k
5X: ±0.625 V 12.5X: ±1.6 V
5X: ±0.625 V 12.5X: ±1.6 V
+4.0 to 2.0 V
+4.0 to 2.0 V
2.5 to 1.5 V 2.5 to 1.5 V
100 k 100 k
5X: ±0.625 V 12.5X: ±1.6 V
5X: ±0.625 V 12.5X: ±1.6 V
+4.0 to 2.0 V
+4.0 to 2.0 V
2.5 to 1.5 V 2.5 to 1.5 V
See TekFlex Accessory Performance Table
See TekFlex Accessory Performance Table
See TekFlex Accessory Performance Table
Interface TekConnect TekConnect TekConnect TekConnect TekConnect TekConnect TekConnect
TekConnect
TekConnect
TekConnect
TekConnect
TekConnect Flex Channel Flex Channel Flex Channel
TekFlex Accessory Table
LEARN MORE
TekFlex Accessory
P77STFLXA P77STFLXB P77STCABL
P77BRWSR
P77C292MM
Attenuation
Input
Differential Input Operating
Impedance
Voltage
Window
4X
100k || 0.4 pF
5 V
±5.25V
10X
150 k || 22 pF
12 V
Variable
50 (SMA)
2 V
±10 V ±4 V
Offset Range
±4V
±10 V ±4 V
11
PASSIVE
ACTIVE
POWER RAIL
DIDFIFFFEERREENNTTIIAALL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
TriMode Probes — Low Voltage Differential & Single-ended — P7500 Accessories
ISOLATED
OPTICAL
DC Calibration Fixture
Use this fixture to calibrate your probes’ DC accuracy when making critical measurements.
G3PO/SMPM Bullet Removal Tool
G3PO/SMPM Bullet Replacement Kit
RF Connector Maintenance
High performance RF connectors can often be fragile. Use these accessories to perform regular maintenance checks on your high performance probe to make sure you are getting the best signal integrity.
High Temp & High Density
Damped Wire Tip
Order #: 020-2959-XX, Kit of 25 Low cost solder tip. Not TriMode capable. Used with the 020-2954-00 Socket Cable. Up to 8 GHz bandwidth.
TriModeTM High Temperature Tip Order #: 020-2958-XX, Kit of 10 High temperature tip with a -55°C to 150°C range. Used with the 020-2960-XX Socket Cable XL. Up to 6 GHz bandwidth.
TriModeTM Micro-Coax Tip
Order #: 020-2955-XX, Kit of 10 Quick connect solder tip. Used with the 020-2954-XX Socket Cable. Up to 4 GHz bandwidth.
Mid-bus Probing
TriModeTM Resistor Solder Tip Order #: 020-2936-XX, Kit of 1 High performance solder tip. Easy to solder tip resistors. Up to 18 GHz bandwidth.
TriModeTM Extended Resistor Solder Tip Order #: 020-2944-XX, Kit of 1 Medium performance solder tip. Easy to solder extra long tip resistors. Up to 7 GHz bandwidth.
TriModeTM Long Reach Solder Tip Order #: P75TLRST, Kit of 1 High performance solder tip. Up to 20 GHz bandwidth.
TriModeTM Performance Solder Tip Order #: P75PST, Kit of 1 High performance solder tip. Up to 25 GHz bandwidth.
Memory Testing
TriModeTM Long Reach Solder Tip (75 tip resistor) Order #: 020-3131-XX, Kit of 1 High performance solder tip for use with memory chip interposers with embedded 100 resistors. Up to 20 GHz bandwidth
TriModeTM Long Reach Solder Tip (0 tip resistor) Order #: 020-3135-XX, Kit of 1 High performance solder tip for use with memory chip interposers with embedded 175 resistors. Up to 20 GHz bandwidth.
Precision Browsing
Precision Differential Probing Module Order #: P75PDPM High performance handheld probing module. Up to 18 GHz bandwidth.
12
PASSIVE
ACTIVE
POWER RAIL
DIDFIFFFEERREENNTTIIAALL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
TriMode Probes — Low Voltage Differential & Single-ended — P7600 Accessories
ISOLATED
OPTICAL
DC Calibration Fixture
Use this fixture to calibrate your probes’ DC accuracy when making critical measurements.
G3PO/SMPM Bullet Removal Tool
G3PO/SMPM Bullet Replacement Kit
RF Connector Maintenance
High performance RF connectors can often be fragile. Use these accessories to perform regular maintenance checks on your high performance probe to make sure you are getting the best signal integrity.
P76CA-292C
33 GHz Bandwidth Coaxial Adapter with 2.92 mm (Male) connectors and 6″ of high performance cable. This adapter is calibrated at the input connectors and is ideal for directly connecting to devices with 2.92 mm or SMA output connectors.
P76CA-SMP
33 GHz Bandwidth Coaxial Adapter with SMP (Female) connectors and 6″ of high performance cable. This adapter is calibrated at the input connectors and is ideal for directly connecting to devices with SMP output connectors.
P76TA
30 GHz Bandwidth P7500 Tip Adapter. The probe and oscilloscope system will support up to 30 GHz of bandwidth when this adapter is used with the P75PST Performance Solder Tip.
P76CA-292
33 GHz Bandwidth Coaxial Adapter with 2.92 mm (Female) connectors. This adapter is calibrated at the input connectors and is ideal for use with off the shelf or custom cables. Low skew cable pairs should be used to preserve full bandwidth performance.
P75PST
High performance solder tip
Unique probe filters
The P7600 Series probes contain probe specific S-parameter data. Attaching a P7600 probe to a MSO/DPO70000DX or DPO70000SX oscilloscope transfers this data to the instrument to create unique system DSP filters based on the specific S-parameter data of the oscilloscope and the probe. Creating unique filters based on the specific response of the system is critical as bandwidths increase. At bandwidths of 33 GHz, small variations in the signal path can lead to significant variation in frequency response. These variations are corrected using DSP filtering.
13
PASSIVE
ACTIVE
POWER RAIL
DIDFIFFFEERREENNTTIIAALL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPTICAL
TriMode Probes — Low Voltage Differential & Single-ended — P7700 & TDP7700 TekFlexTM Accessories
DC Calibration Fixture
Order #: 067-4889-xx
Use this fixture to calibrate your probes DC accuracy when making critical measurements. For P7700 probes.
Probe Deskew Fixture
Order #: P77DESKEW
Use this fixture to time align your TekFlex probes for the best timing accuracy to make critical timing measurements.
P77BRWSR
16 GHz handheld browser accessory enables hand or fixtured probing with adjustable tip spacing. The browser’s tips are adjustable in spacing using a convenient thumb wheel. A headlight on the tip enhances visibility of the probe point and can be switched on and off as needed.
The browser tips are constructed of high strength BeCu and super-ceramic resistors. Each pin has integrated pogo springs and a crown cut tip to help make solid mechanical connections to components and traces.
Probe Stand and wand accessories for both hands free and hands on browsing give you flexibility when you are debugging your circuit.
TekFlex connector technology
The P7700 & TDP7700 Series TriMode probes use the TekFlex connector technology that combines a highspeed signal path with power and communication support for an active buffer tip in a single, easy to attach accessory connector. The TekFlex connector has a pinch-to-open design that when open requires minimal force to attach an accessory tip. When the TekFlex connector is closed, it provides a secure connection to the accessory to avoid accidental disconnections.
P77C292MM
SMA/2.92mm adapter for connecting to coaxial connectors RF/coaxial connectors, such as SMA, are often found on test fixtures or on prototype board designs. Attaching a P7700 or TDP7700 series probe to these on-board connectors is easy with the SMA adapter.
The P77C292MM adapter includes TriMode functionality enabling differential, single ended, and common mode measurements. Include variable termination voltage that can be set manually or automatically using voltage sense circuitry in the P7700 or TDP7700 probes over a range of ±4 V for testing display technologies like HDMI and Display Port.
P77STCABL
20 GHz solder down accessory with a long reach, flexible cable combined with an active buffer amplifier on the tip. The long tip reach make it great for escaping tight board geometries while maintaining electrical performance.
P77STFLXA
20 GHz solder down, flex-circuit accessory with an active buffer amplifier on its tip. Each tip has a stored factory AC calibration which is de-embedded automatically on the instrument
P77STFLXB
16 GHz solder down, flex-circuit accessory provides a probing solution for DDR4 and LPDDR4 electrical validation when used with Nexus XH Series Interposers. Each tip has a stored factory AC calibration and a nominal XH series interposer response which is de-embedded automatically on the instrument
P77STFLRB / P77HTFLRB
16 GHz solder down, Long-Reach, flex-circuit accessory provides a probing solution for DDR and LPDDR electrical validation when used with Nexus XH Series Interposers. The FLR tips’ increased flexibility and long reach helps access inaccessible test points. Each tip has a stored factory AC calibration and a nominal XH series interposer response which is de-embedded automatically on the instrument.
P77STFLRA / P77HTFLRA
20 GHz solder down, Long Reach, flex-circuit accessory with an active buffer amplifier on its tip. The FLR tips’ increased flexibility and long reach helps access inaccessible test points. Each tip has a stored factory AC calibration which is de-embedded automatically on the instrument.
14
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
CCUURRRREENNTT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPTICAL
Current Probes
Tektronix current probe solutions offer:
· The broadest range of AC/DC and AC-only current probes
· Measurement accuracy from As to 2000 A
· Best-in-class bandwidth up to 120 MHz
· Best-in-class current clamp sensitivity down to 1 mA
· The only products with 3rd Party Safety Certification (UL, CSA, ETL)
· The only products with bare wire voltage ratings
· Automatic readout and scaling when used with Tektronix oscilloscopes so you don’t have to convert volts to amps or manually set the scaling
DC/AC
Model
Maximum Current
Minimum Current*
Bandwidth Rise Time
TCPA300
Current Probe Amplifier
TCP312A TCP305A TCP303 TCPA400
30 A DC; 21.2 ARMS; 50 A peak
1 mA
50 A DC; 35.4 ARMS; 50A peak
5 mA
150 A DC; 150 ARMS; 500A peak
5 mA
Current Probe Amplifier
DC – 100 MHz DC 50 MHz DC 15 MHz
3.5 ns 7 ns 23 ns
TCP404XL
500 A DC; 500 ARMS; 750 A peak
1 A
DC – 2 MHz
TCP0030A
30 A DC; 30 ARMS; 50 A peak
1 mA
DC – 120 MHz
TCP0020
20 A DC; 20 ARMS; 100 A peak
10 mA
DC – 50 MHz
TCP2020
20 A DC; 20 ARMS; 100 A peak
10 mA
DC – 50 MHz
TCP0150
150 A DC; 150 ARMS; 500 A peak
5 mA
DC – 20 MHz
A622
100 A DC; 70.7 ARMS; 100 A peak
DC 100 kHz
*Winding the conductor multiple times through the current probe jaws increases the sensitivity.
175 ns 2.92 ns
7 ns 7 ns 17.5 ns 3.5 s
Interface TekProbe LVL 2
Amplifier Amplifier Amplifier TekProbe LVL 2 Amplifier
TekVPI TekVPI
BNC TekVPI
BNC LEARN MORE
TCP0030A
TCPA300
TCP312A
TCP303
A622
15
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
CCUURRRREENNTT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPTICAL
Current Probes continued
P6021A
AC Only
Model
Maximum Current
Minimum Current
Sensitivity*
Bandwidth
P6021A
10.6 A ; RMS 250 A peak
2 mA/mV, 10 mA/mV
120 Hz – 60 MHz
P6022
4 A ; RMS 100 A peak
1 mA/mV, 10 mA/mV
935 Hz – 120 MHz
TRCP3000
3000 A peak
500 mA
2 mV/A
1 Hz – 16 MHz
TRCP0600
600 A peak
500 mA
10 mV/A
12 Hz – 30 MHz
TRCP0300
300 A peak
250 mA
20 mV/A
9 Hz – 30 MHz
CT1
450 mA ; RMS 12 A peak
5 mV/mA
25 kHz 1 GHz
CT2
2.5 A ; RMS 36 A peak
1 mV/mA
1.2 kHz 200 MHz
CT6
120 mARMS; 6 A peak
5 mV/mA
250 kHz 2 GHz
A621
1000 ARMS; 2000 A peak
100 mA
1 mV/A
5 kHz 50 kHz
*Winding the conductor multiple times through the current probe jaws increases the sensitivity.
Interface
TekProbe
BNC BNC BNC BNC BNC BNC BNC BNC LEARN MORE
TRCP3000
CT1
CT6
A621
16
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
CURRENT
HIHGIHGHVVOOLLTTAAGGEE
High Voltage Probes – Single-ended
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPTICAL
A high voltage single-ended probe is typically used for measuring ground referenced signals up to 40 kV. However, some single-ended probes are designed for instruments with isolated or floating inputs for measurements that are not ground referenced. Users should select probes with a low input capacitance specification (< 4 pF) to minimize the probe’s loading effect on the circuit because a probe with lower input capacitance will offer higher input impedance at higher frequencies.
Tektronix High Voltage Probe solutions offer:
· Best-in-class bandwidth up to 800 MHz
· Best-in-class probe loading with input capacitance as low as 1.8 pF
· The only products with 3rd Party Safety Certification (UL, CSA, ETL)
· Most extensive set of probe accessories
Model Bandwidth
Max Voltage
Attenuation
Input Impedance
Compensation Range
Interface
P5100A 500 MHz
1000 VRMS (CAT II) 2.5kV peak
100X
40 M|| 2.5 pF
7 pF 30 pF
TekProbe LEVEL 1
P6015A
75 MHz
20 kVRMS 40 kV peak
1000X
100 M|| 3 pF
7 pF 49 pF
TekProbe L1 or BNC
P5122
200 MHz
1000 VRMS (CAT II)
TPP0850 800 MHz
1000 VRMS (CAT II) 2.5kV peak
100X 50X
100 M|| 4.6 pF 10 pF 25 pF
BNC
40 M|| 1.8 pF
Auto compensated by
scope
TekVPI
LEARN MORE
P6015A
P5100A
TPP0850
17
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
CURRENT
HIGH VOLTAGE
HIGHIHGHVVOOLLTTAAGGEE DIFDIFFEFERREENNTTIIAALL
Differential Probes High Voltage
ISOLATED
OPTICAL
A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at ground. High voltage differential probes from Tektronix can be used for signals up to 6000 V. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability. These products are designed, manufactured, and serviced by Tektronix.
Tektronix High Voltage Differential Probe solutions offer:
· Best-in-class bandwidth and probe loading
· The only products with 3rd Party Safety Certification (UL, CSA, ETL)
· High and medium voltage products to support varying dynamic range and measurement resolution requirements
· Most extensive set of probe accessories
THDP0100
P5200A
THDP0200/TMDP0200
Model
Bandwidth
P5200A P5202A P5205A P5210A TMDP0200 THDP0200 THDP0100
50 MHz 100 MHz 100 MHz 50 MHz 200 MHz 200 MHz 100 MHz
Rise Time
7.8 ns 3.8 ns 3.8 ns 7.8 ns 1.8 ns 1.8 ns 3.5 ns
Attenuation
50:1 / 500:1 20:1 / 200:1 50:1 / 500:1 100:1 / 1000:1 25:1 / 250:1 50:1 / 500:1 100:1 / 1000:1
Maximum Differential
Voltage ±1300 V
±640 V
±1300 V
±5600 V
±750 V
±1500 V
±6000 V
Maximum Voltage to Earth Ground
Differential Input
Capacitance
1000 Vrms (CAT II)
2 pF
300 Vrms (CAT II)
2 pF
1000 Vrms (CAT II)
2 pF
2300 Vrms (CAT I)
2.5 pF
550 Vrms (CAT I)
2 pF
1000 Vrms (CAT II)
2 pF
2300 Vrms (CAT I)
2.5 pF
Single Ended Input Capacitance
4 pF
4 pF
4 pF
5 pF
4 pF
4 pF
5 pF
Differential Input
Resistance 10 M
5 M
10 M
40 M
5 M
10 M
40 M
Single Ended Input Resistance
5 M
2.5 M
5 M
20 M
2.5 M
5 M
20 M
Cable Length (Tpropagation)
1.5 m (21 ns)
1.5 m (21 ns)
1.5 m (21 ns)
1.5 m (21 ns)
1.5 m (21 ns)
1.5 m (21 ns)
1.5 m (21 ns)
Interface
BNC (1 M) TekProbe LVL 2 (1 M) TekProbe LVL 2 (1 M) TekProbe LVL 2 (1M) VPI (1 M)
VPI (1M)
VPI (1 M)
LEARN MORE
18
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
Differential Probes High Voltage Accessories
CURRENT
HIGH VOLTAGE
HIGHIHGHVVOOLLTTAAGGEE DIFDIFFEFERREENNTTIIAALL
ISOLATED
OPTICAL
Accessory AC280-FL AC283-FL AC285-FL 020-3107-00 012-1724-00 344-0670-00
Description
Hook Clip X2
Micro Grabber Tip X2
Alligator Clip (large) X2
Pogo Pin Adapter Kit X2
Test Probe Extension (fine point) Adapter X2
Alligator Clip (small) X2
P5205A
450 Vrms CAT I 300 Vrms CAT II
STANDARD
450 Vrms CAT I 300 Vrms CAT II
STANDARD
450 Vrms CAT I 300 Vrms CAT II
STANDARD
150 Vrms CAT II
OPTIONAL
300 Vrms CAT I 300 Vrms CAT II
OPTIONAL
450 Vrms CAT I 300 Vrms CAT II
OPTIONAL
P5200A/P5205A 1000 Vrms CAT II 600 Vrms CAT III
STANDARD 1000 Vrms CAT II 600 Vrms CAT III
STANDARD 1000 Vrms CAT II 600 Vrms CAT III
STANDARD 150 Vrms CAT II
OPTIONAL
300 Vrms CAT II
OPTIONAL
1000 Vrms CAT II 600 Vrms CAT III
OPTIONAL
THDP0100/P5210A
1000 Vrms CAT I 1000 Vrms CAT III
OPTIONAL
1000 Vrms CAT I 1000 Vrms CAT III
OPTIONAL
1000 Vrms CAT I 1000 Vrms CAT III
OPTIONAL
150 Vrms CAT II
OPTIONAL
300 Vrms CAT I 300 Vrms CAT II
OPTIONAL
THDP010: 300 Vrms CAT I P5210A: 1000 Vrms CAT I
1000 Vrms CAT III
OPTIONAL
TMDP0200 550 Vrms CAT I 300 Vrms CAT III
STANDARD 550 Vrms CAT I 300 Vrms CAT III
STANDARD 550 Vrms CAT I 300 Vrms CAT II
STANDARD 150 Vrms CAT II
STANDARD 300 Vrms CAT I 300 Vrms CAT II
STANDARD
300 Vrms CAT I
STANDARD
THDP0200 1000 Vrms CAT II 600 Vrms CAT III
STANDARD 1000 Vrms CAT II 600 Vrms CAT III
STANDARD 1000 Vrms CAT II 600 Vrms CAT III
STANDARD 150 Vrms CAT II
STANDARD
300 Vrms CAT II
STANDARD
300 Vrms CAT I
STANDARD
19
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
CURRENT
IsoVuTM Isolated Voltage Probe
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISISOOLLAATTEEDD
OPTICAL
IsoVuTM probes are the right tool for today’s demanding power measurement challenges given their industry leading 1 GHz bandwidth, 160 dB or 100 Million to 1 common mode rejection, 60 kV common mode voltage, large ± 3300 V differential range and superior probe loading.
Optimize for Performance and Efficiency
The benefits of a power design can only be realized when the switching circuit, the gate drive circuit, and the layout are all properly designed and optimized. lsoVu can be used to:
· Characterize the gate drivers, Vgs, Vds, and Is
· Characterize the time alignment of high and low side events
· Optimize and tune the switching characteristics
Model
TIVP02 TIVP02L TIVP05 TIVP05L
TIVP1 TIVP1L
Bandwidth Rise Time
200 MHz 200 MHz 500 MHz 500 MHz
1 GHz 1 GHz
2 ns 2 ns 850 ps 850 ps 450 ps 450 ps
Cable Length
2 m 10 m 2 m 10 m 2 m 10 m
Maximum Differential
Input Voltage
3300 V**
3300 V**
3300 V**
3300 V**
3300 V**
3300 V**
Maximum Offset range
±2500 V** ±2500 V** ±2500 V** ±2500 V** ±2500 V** ±2500 V**
Maximum Common
Mode Voltage to
Earth
60 kV
60 kV
60 kV
60 kV
60 kV
60 kV
Interface
VPI (4/5/6 Series)
VPI (4/5/6 Series)
VPI (4/5/6 Series)
VPI (4/5/6 Series)
VPI (4/5/6 Series)
VPI (4/5/6 Series)
LEARN MORE
20
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
IsoVuTM Isolated Voltage Probe Accessories
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISISOOLLAATTEEDD
OPTICAL
TIVM Tip Model
Attenuation
SMA Input (50 Mode)
SMA Input (1 M Mode)
TIVPMX10X
TIVPMX50X
TIVPSQ100X
1:1
1:1 10:1 50:1 100:1
TIVPWS500X
500:1
TIVPMX1X
1:1
Differential Voltage
±5 V
±5 V ±50 V ±250 V ±500 V
±2.5 kV
±5 V
Offset Range
Input Impedance
Max Non-Destruct Voltage
Vpk (DC + peak AC) 1
DC – 1 MHz
CMRR 1 MHz 100 MHz 200 MHz 500 MHz
1 GHz
±25 V
50 || N.A.
5 V RMS
160 dB 145 dB 100 dB 100 dB 100 dB 90 dB
±25 V
1 M || 11 pF
±200 V 10 M || 2.8 pF ±250 V 10 M || < 5 pF
±500 V 10 M || < 5 pF
100 Vpk 250 Vpk 300 Vpk 600 Vpk
160 dB 145 dB 100 dB 100 dB 100 dB 90 dB
160 dB 160 dB
115 dB 92 dB 104 dB 85 dB
90 dB 80 dB
85 dB 73 dB
80 dB 70 dB
160 dB 100 dB 70 dB 57 dB 39 dB 30 dB
±2.5 kV 40 M || < 4 pF
±25 V
50 or 1 M || 11 pF
3300 Vpk
5 V RMS (50 ) 100 Vpk(1 M)
160 dB 100 dB 60 dB 48 dB 33 dB 25 dB 160 dB 145 dB 100 dB 100 dB 100 dB 90 dB
Standard Attachment
Sensor Tip Sensor Tip 0.1″ Square
Pin 0.1″ Wide Square Pin Sensor Tip
21
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
CURRENT
IsoVuTM Isolated Current Probes
Make more accurate dynamic shunt-based current measurements with TICP Series Current Probes. High bandwidth, flexible ranges, complete galvanic isolation and extremely low noise enable you to go beyond traditional limits ideal for low noise measurements on current shunts in floating sections of power circuits.
· Measurements from DC to hundreds of MHz when paired with high-performance shunts or CVRs.
· Complete RF isolation between the probe tip and the scope eliminates ground loops and dramatically reduces common mode noise.
· Low attenuation, 50 ohm input impedance, and shielded tips ensure a low noise contribution.
Model TICP025
Bandwidth 250 MHz
TICP050
500 MHz
TICP100
1 GHz
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISISOOLLAATTEEDD
OPTICAL
Differential Voltage
±0.5V (1X Tip) ±5V (10X Tip) ±50V (100X Tip)
±0.5V (1X Tip) ±5V (10X Tip) ±50V (100X Tip)
±0.5V (1X Tip) ±5V (10X Tip) ±50V (100X Tip)
Common Mode Voltage
1800 V Pollution Degree 1 1000 V CAT II
1800 V Pollution Degree 1 1000 V CAT II
1800 V Pollution Degree 1 1000 V CAT II
Common Mode Rejection Ratio
140 dB at DC up to 90 dB at 1 MHz
140 dB at DC up to 90 dB at 1 MHz
140 dB at DC up to 90 dB at 1 MHz
LEARN MORE
IsoVu Current probe clearly shows the ringing.
TICP100
22
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
IsoVuTM Isolated Current Probes Accessories
TICPMM100
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISISOOLLAATTEEDD
OPTICAL
Accessory TICPMM100 196-3546-xx 131-9677-xx 196-3547-xx 206-0569xx
Description 100X sensor tip cable with MMCX connector
Lead, MMCX to IC grabber Square pin to MMCX adapter, 0.062″ spacing
Square pin to IC grabber lead MicroCKT grabbers
196-3546-xx
196-3547-xx
131-9677-xx
206-0589-xx
23
PASSIVE
ACTIVE
POWER RAIL
DIFFERENTIAL
CURRENT
HIGH VOLTAGE
HIGH VOLTAGE DIFFERENTIAL
ISOLATED
OPOTPITCICAALL
Optical Probes
High Bandwidth
Model
Electrical
DPO7OE1
33 GHz
DPO7OE2
59 GHz
Bandwidth (-3 dB)
750 nm to 1650 nm Calibrated at 850 nm,
1310 nm, 1550 nm
1200 nm to 1650 nm Calibrated at 1310 nm,
1550 nm
Wavelength Range
Opt. FC/PC
FC/PC: 50 m SMF and MMF compatible
FC/PC: 9 m SMF compatible
Input Fiber
FC/APC: 9 m SMF compatible
FC/APC: 9 m SMF compatible
Oscilloscope Interface
ATI (1.85 mm RF connector) and
TekConnect
ATI (1.85 mm RF connector) and
TekConnect
The DPO7OE Series Optical Probes paired with a DPO70000 real time oscilloscope delivers high performance and advanced debug capabilities that are necessary for designers to fully troubleshoot 400G PAM4 signals (up to 56 GBd) and reduce time to market needs. These probes can also be used as a conventional O/E with a flat frequency response for general signal acquisition up to their respective bandwidth: 33 GHz using the DPO7OE1 or 59 GHz using the DPO7OE2.
· Versatile and modular design for use with multiple high-performance real time oscilloscope models
· Broad wavelength range with FC/PC and FC/APC connector options
· Deep optical PAM4 and PAM2 (NRZ) signal analysis and error detection
· User selectable Optical Reference Receivers (ORR)
DPO7OE Series Optical probes using the TekConnect channel on a MSO73304DX Oscilloscope
Rise Time (10% to 90%)
Optical Noise
Maximum Input Power (Linear
Response)
10.2 ps, typical
6.6 W rms (TekConnect / ATI)
4 mW, typical
7.5 ps, typical
10 W rm (ATI)
2 mW, typical
LEARN MORE
DPO7OE Series Optical probes using the TekConnect channel on a MSO73304DX Oscilloscope
24
Find more valuable resources at TEK.COM
Copyright © Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 11/2024 SBG 61W-14232-13
Documents / Resources
![]() |
Tektronix TPP0500B Probe Oscilloscope [pdf] User Guide TPP0500B Probe Oscilloscope, TPP0500B, Probe Oscilloscope, Oscilloscope |