S4A LogoHD3 Acces Controller Reader
User ManualS4A HD3 Acces Controller ReaderUser Manual

INTRODUCTION

The device is a single door multifunction standalone access controller or a Wiegand output reader. It uses Atmel MCU assuring stable performance.
The operation is very user-friendly, and low-power circuit makes it long service life.
The device can be made with Bluetooth function or with WIFI function.
Card/ PIN device:
It supports 10,000 users (9988 common + 2 panic + 10 visitor)
Card/ PIN/ Fingerprint device:
Three user capacities are available:

  1. It supports 10,000 card/ PIN users + 100 fingerprint users
  2. It supports 10,000 card/ PIN users + 500 fingerprint users
  3. It supports 10,000 card/ PIN users + 880 fingerprint users

Features
> OLED display, touch keypad
> Wide: ABS, Slim: metal case, anti-vandal
> Waterproof, conforms to IP66
> One relay
> PIN length: 4~6 digits
> EM card, EM+ Mifare card optional
> EM card: Wiegand 26~44 bits input & output Mifare card: Wiegand 26~44bits, 56bits, 58bits input & output
> Can be used as Wiegand reader with LED & buzzer output
> Card block enrollment
> Tri-color LED status display
> Integrated alarm & buzzer output
> Pulse mode, Toggle mode
> User data can be transferred
> 2 devices can be interlocked for 2 doors
> Built-in light dependent resistor (LDR) for anti tamper
> Backlit keypad, can set automatic OFF after 20 seconds

User Capacity Card/ PIN Card/ PIN/ Fingerprint
Common Card/ PIN User Common Fingerprint User Panic User
Visitor User
9988 /
2
10
9988
500 (100, 880 optional)
2
10
Operating Voltage
Working Current Idle Current
12V DC (Wide device) 12-18V DC (Slim device) <150mA <60mA
Proximity Card Reader Radio Technology
Read Range
EM or EM+Mifare
125KHz or 125KHz+ 13.56MHz 2-6 cm
PIN Length 4-6 digits
Wiring Connections Relay Output, Exit Button, Alarm, Door Contact, Wiegand Input, Wiegand Output
Relay
Adjustable Relay Output Time Lock Output Load
One (NO, NC, Common)
0-99 Seconds (5 seconds default) 2 Amp Maximum
Wiegand Interface
PIN Output
EM card version: Wiegand 26-44 bits
input & output (Factory Default: Wiegand 26bits)
Mifare card version: Wiegand 26-44bits, 56bits, 58bits input & output
(Factory Default: Wiegand 34bits)
4 bits, 8 btts(ASCII), 10 dialtsVktual Number
(Factory Default: 4 bits)
Environment
Operating Temperature
Operating Humidity
Meets IP66
Card/ PIN device: -40°C- 60°C (-40°F – 140°F) Card/ PIN/ Fingerprint device: -30°C – 60°C (-22°F – 140°F)
0%RH-98%RH
Physical
Colour
Dimensions
Unit Weight Shipping Weight
Wide: ABS Slim: Zinc-Alloy
Wide: Black Slim: Silver & Black
Wide: L116 x W76 x D24 (mm) Slim: L148 x W43.5 x D22 (mm)
Wide: 160g Slim: 330g
Wide: 185g Slim:405g

Wiring (for Wide device)

Color Function Notes
Red +12V 12V DC Power Input
Black GND Negative Pole of DC Power Input
Blue NO Normally Open Relay Output
Purple COM Common Connection for Relay Output
Orange NC Normally Closed Relay Output
Yellow OPEN Request to Exit (REX)Input
White D1 Wiegand Output /Input Data 1
Green DO Wiegand Output /Input Data 0
Grey Alarm Output Negative contact for Alarm
Brown Contact Output Door/Gate Contact Input (Normally Closed)
Light Blue Doorbell A Contact for Doorbell
Light Blue Doorbell B Contact for Doorbell

Wiring (for Slim device)

Wire Color Function Notes
Basic Standalone Wiring
Red DC+ 12-18V DC Power Input
Black G N D Negative Pole of DC Power Input
Blue & Black Relay NO Normally Open Relay Output (install diode provided)
White & Black Relay Common Common Connection for Relay Output
Green & Black Relay NC Normally Closed Relay Output (Install diode provided)
Yellow OPEN Request to Exit(REX) Input
Pass-Through Wiring (Wiegand Reader or Controller)
Green Data 0 Wiegand Output (Pass-through) Data 0
White Data 1 Wiegand Output (Pass-through) Data 1
Advanced Input and Output Features
Grey Alarm Output Negative contact for Alarm
Brown Contact Input Door/Gate Contact Input (Normally Closed)
Brown & Black Doorbell A Contact for Doorbell
Yellow & Black Doorbell B Contact for Doorbell

Carton Inventory

S4A HD3 Acces Controller Reader - Carton inventory

INSTALLATION

  • Remove the back cover from the unit
  • Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
  • Knock the supplied rubber bungs to the screw holes(A,C)
  • Fix the back cover firmly on the wall with 4 flat head screws
  • Thread the cable through the cable hole(B)
  • Attach the unit to the back cover

S4A HD3 Acces Controller Reader - Drill

CONNECTION DIAGRAM :

Standalone Mode
The device can work as Standalone Access Control for single door.
(Factory default mode)
Connection Diagram (for Wide device)
Common Power SupplyS4A HD3 Acces Controller Reader - ConnectionAttention:
Install a 1N4004 or equivalent diode is needed when use a common power supply, or the keypad might be damaged. (1N4004 is included in the packing)
Access Control Power SupplyS4A HD3 Acces Controller Reader - Power Supply

Connection Diagram (for Slim device)
Common Power Supply

S4A HD3 Acces Controller Reader - Common Power Supply

Attention:
Install a 1N4004 or equivalent diode is needed when use a common power supply, or the keypad might be damaged. (1N4004 is included in the packing)
Access Control Power SupplyS4A HD3 Acces Controller Reader - Control Power

Controller Mode
The device can work as Controller, connected with the external Wiegand reader.
(Factory default mode)
Connection Diagram (for Wide device)S4A HD3 Acces Controller Reader - Special PowerConnection Diagram (for Stim device)S4A HD3 Acces Controller Reader - Slim DeciceAttention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is included in the packing)

WIEGAND READER MODE

The device can work as Standard Wiegand Reader, connected to the third party Controller
Connection DiagramS4A HD3 Acces Controller Reader - Access Controller

Notes:

  • When set into Wiegand Reader mode, nearly all settings in Controller Mode will become invalid, and Brown & Yellow wires will be redefined as below:
    – Brown wire: Green LED light control
    – Yellow wire: Buzzer control
  • If you need to connect Brown/Yellow wires:
    When the input voltage for LED is low, the LED will tum into Green; and when the input voltage for Buzzer is low, it will sound.

PROGRAMMING

Keys & Functions 
0~9: Enter value, menu number

S4A HD3 Acces Controller Reader - Symbol # Ok means confirm
▼ means down to select
S4A HD3 Acces Controller Reader - Symbol 1 Means doorbell
S4A HD3 Acces Controller Reader - Symbol 2 M means menu
Short press * means back to the previous menu
Long press * means back to main interface

System Menu

> Please input * (Master Code) # to enter system menu.
(Factory default master code is 123456)
> User ID number:
The Common Card/PIN User ID: 1~9988
Panic User ID: 9989~9990
Visitor User ID: 9991~10000
Fingerprint User ID (Only apply to card/PIN/ Fingerprint device)
10001~10100 or 10001~10500 or 10001~10880
> PIN: Can be any 4~6 digits
> Proximity Card: 125KHz EM card or 13.56MHz Mifare card

  1. Change Admin
    Press ‘1’ to enter Change Admin.
    Menu No. Setting Note
    1 Change Admin New Admin can be any 6 digits
  2. User Setting
    Press ‘2’ to enter User Setting.
    Press ▼ to select and long press # to confirm.
    Menu No Setting Note 
    1 Add Directly Add users directly by inputting PIN/ card
    2 Add by ID Add users by user ID.
    The common user ID is between 1~9988, panic
    User ID is 9989~9990.
    Fingerprint User ID (Only apply to card/PIN/
    Fingerprint device) is 10001~10100 or
    10001~10500 or 10001~10880.
    3 Add Visitor – Visitor user ID is between 9991~10000
    – Add visitor card: ID# (1~9)# (read card)
    – Add visitor PIN: ID# (1~9)# (PIN)#
    1~9 means times of usage.
    4 Block Enrol Choose the 1st ID–Set Card Number (can set 1~200)– Read the 1st number card
    5 Del Directly – Enter PIN or card to delete user directly
    6 Del by ID – Delete users by inputting user ID
    7 Del All User – Delete ALL users
  3. Door Setting
    Press ‘3’ to enter Door Setting.
    Press ▼ to select and long press # to confirm.
    Menu No. setting  Note
    1 Open Time – Open time can be set to 0~100s
    Input 0-100, long press # to confirm.
    – Factory default is 5s
    2 Access Mode Access Modes can be set to:
    Card/ PIN device: 1 Card, 2 PW, 3 Card/PW,
    4 Multi User (max.9)
    Card/ PIN/ Fingerprint device: 1 Card, 2 PW,
    3 Fingerprint, 4 Card/PW/Fp, 5 Multi User
    (max.9)
    3 Alarm Time – 1 OFF (Factory default)
    -2 1min
    -3 2min
    – 4 3min
    4 Door Contact – 1 OFF (Factory default)
    -20N
    5 Security Mode – 1 OFF (Factory default)
    -2 LOCK Dead
    The device will become ‘access deny’ for 10 minutes after 10 failed entry attempts.
    Restart the device to back to normal.
    – 3 Alarm Mode
    The device will alarm after 10 failed entry attempts. Alarm time depends on the device alarm time (refer to Door Setting Menu No.
    3 Alarm Time),enter Master Code # or valid user card/PIN to silence.
    6 Interlock – 1 OFF (Factory default)
    -20N
    Connection Diagram please refer to page 12
    7 Collect Card – 1 OFF (Factory default)
    -20N
    After this function is turned ON, all cards can open the lock, at the same time, the card is added to the device.
    8 WG FMT – 1 Check OFF
    – 2 Check ON (Factory default)
    Check means Parity Bit
    -3 4bits (Factory default)
    – 4 Bbits
    – 5 10bits (VirNum)
    – 61D: 26
    Wiegand format for EM card can be set to 26~44,
    – TIC: 34
    Wiegand format for Mifare card can be set to 26~58.
    9 Working Mode – 1 Controller (Factory default)
    – 2 Reader
    In Controller mode, the device can be also used as standalone.
    Connection diagram please refer to Page 4~6
  4. Other Setting
    Press ‘4’ to enter Other Setting.
    Press ▼ to select and long press # to confirm.
    Menu No. Setting Note
    1 Sound – 1 OFF
    – 2 ON (Factory default)
    2 Red Led -1 OFF
    – 2 ON (Factory default)
    3 Keys Backlight -1 OFF
    – 2 ON
    – 3 Auto (Factory default)
    Automatic OFF after 20 seconds, it will go ON by pressing any key (this key isn’t taken Into considerations).
    4 OLED Backlight -1 ON
    – 2 5S
    – 3 10S
    – 4 30S (Factory default)
    – 5 1min
    5 Unbind Machine – Unbind the device
    – Long press # to confirm Unbind, the device will back to main interface after unbinding successfully.
    6 Copy Users Connection diagram please refer to page 11
    7 Factory Reset Reset to factory default, the user’s information is still retained.

ADVANCED APPLICATION

User Information Transfer (Valid for Card/ PIN device)
The device supports the User Information Transfer function, and the enrolled user (cards, PINs) can be transferred from one (let’s name it Master Unit) to another (let’s name it Accept Unit).
Connection Diagram:

S4A HD3 Acces Controller Reader - Power 1

Remarks:

> The Master units and Accept units must be same series devices.
> The Master Code of the Master Unit and the Accept Unit must be set to the same.
> Program the transfer operation on Master Unit only.
> If the Accept Unit is already with the users enrolled, it will be covered after transferring.
> For full 10000 users enrolled, the transfer takes about 5 minutes.
Set Transferring on Master Unit: Menu 4 Other Setting— 6 Copy User

Interlock

The device supports the Interlock Function. It is of two Devices for two doors, and mainly used for banks, prisons, and other places where a higher level security is required.
Connection Diagram:S4A HD3 Acces Controller Reader - DC Power Supply

Remarks: The Door Contact must be installed and connected as the diagram.
Let’s name the two Devices as “A “and “B” for two doors “1” and “go
Step 1: 
Enroll the users on Device A, then transfer the users’ information to Device B by ‘User Information Transfer’ function (Page 111)
Step 2: 
Set both of the two Devices (A and B) to Interlock function
Menu 3 Door Setting — 6 Interlock
lf enable interlock, when and only door 2 is closed, the user can read the valid fingerprint/card or input PIN on Reader A, door 1 will open; then when and only door 1 closed, read valid fingerprint/card or input PIN on Reader B, door 2 will open.

SOUND AND LIGHT INDICATION

Operation Status LED Buzzer
Stand by Red light bright
Enter into programming mode Red light shines One beep
In the programming mode Orange light bright One beep
Operation error Three beeps
Exit from the Programming mode Red light bright One beep
Open lock Green light bright One beep
Alarm Red light Shines quickly Beeps