netvox Z810B Wireless Load Control 2T With Power Energy Current Voltage Meter And LCD User Manual
Introduction
Z810B device acts as a simple metering device that provides the user with current consumption (load current, load voltage, power, and energy) Z810B can report its readings to a display device or a PC. This device can be switched through paired switch wirelessly or through the manual switch button.
What is ZigBee?
ZigBee is a short-range wireless transmission technology defined for minimum complexity, low power consumption, low data rate, and cost-effective wireless solution. ZigBee lies in between wireless markup technology and Bluetooth. ZigBee is based on the IEEE802.15.4 standard, the mutual coordination between thousands of sensors to exchange data. Sensor-to-sensor or node-to-node communication is achieved through relays of control data between devices with only a fraction of energy use which is denoted for high transmission efficiency
Note:
Wireless communication, in some real use cases, can be limited by the signal blockage. Please consult your service provider or place of purchase.
Product Specification
- Fully IEEE 802.15.4 compliant (ZigBee Pro)
- Utilizes 2.4GHz ISM band, up to 16 channels.
- 100-240VAC (50/60Hz) input power
- Up to 150 meters of non-obstacle wireless transmission distance
- Simple operation and device configuration
AppearanceOperating Instructions
Power On
Connect the Z810B device to an AC 100-240V power supply, power on the device, and the LCD backlight will light up.
Network Joining
In order to enable Z810B to connect with other devices under the Zigbee network, Z810B needs to be added to the Zigbee network, and the network addition operation is as follows:
(a) Turn on the “allow network addition function” of the coordinator or router device in the same channel as Z810B in the network.
(b) If Z810B is used as a router in the network, it will actively search for the network after power-on and will keep flashing before it joins the network, and the value area will display power information.
(c) If the network is added successfully, the light will remain on and the LCD value area will display the power information. As shown below:
Display power consumption 10.5 kW.
End Device Binding
For the objects that Z810B can be bound to, the client side has on/off Cluster control device binding, such as Z503/Z501 of netvox, the binding operation is as follows:
a) Press and hold the binding key for 3 seconds, the icon will flash once, at this time the LCD value area will display the bind information as shown in the figure:
,and the device will send a binding request. Then operate the control device within 16 seconds to make it also send a binding request. If the binding is successful, the LCD will display “GOOD” as shown in the figure:
It will flash for 3 seconds and then return to the main screen.
If the binding fails, the LCD will display fail as shown in the figure: It will flash for 3 seconds and then return to the main screen. After the binding is successful, you can control the device Z810B to change the switch and level.
(b) Unbind: If the binding operation is performed on the already bound device, it will be unbound.
Note: The device supports 16 Banding tables, 16 Group tables and 16 Scenes tables.
Controlled
Binding control: Send switch/level commands through the bound control device to control the switch loaded on the Z810B
Direct control
The LCD will display the icon when the relay is working, otherwise it will not display.
Allow joining the network function
As a router in the network, Z810B has the function of allowing other devices to join the network as its sub-devices. Simultaneously press the binding key and the function key for 1 second, the icon will flash once, after releasing the key, the LCD value area will display JOIN, and return to the power display screen after 1 second, and the unlock icon
will start flashing , and flashes 60 times. As shown in the picture:
It is allowed to join the network for 1 minute. The device can connect up to 14 End Devices.
Electric energy, power, voltage, current switching display
On the energy display interface, short press the Energy Key button to switch to voltage (in volts), current (in amps), power (in watts), and electric energy (in kWh).
Note: The device can also automatically refresh the power interface, which is refreshed every 5 seconds.
Data reporting time
When the binding request is successful, the device sends data to the device in the binding request. In the case of no configuration time, the default minimum time of Z810B’s 0x0505\0x0508\0x050B attribute is 180 seconds, the maximum time is 300 seconds, and the reportable change is 100. 0x0510 attribute default minimum time is 180 seconds, the maximum time is 300 seconds, and the reportable change is 100.
Z810B’s 0x0000, 0xE000, 0xE001, 0xE002, 0xE003 attributes default minimum time and maximum time are 0xFFFF, and reportable change is 100, which means no report by default.
Min Interval / Max Interval setting:
Min Interval |
Max Interval | Report Change | When data< Report Change | When data≥ Report Change |
0x0001-0xFFFE | 0x0001-0xFFFE | >0 | Max Interval report | Min Interval report |
0x0000 | 0x0001-0xFFFE | Max Interval report | Immediately | |
0x0001-0xFFFE | 0x0000 | Do Not Report | Min Interval report | |
0x0000 | 0x0000 | Do Not Report | Immediately | |
0x0001-0xFFFE | 0xFFFF | Turn off the report of this attribute | Turn off the report of this attribute |
*When the reportable change value is 0, the report will be sent according to the Min interval.
*The Reportable change of each attribute can be configured according to the specific load power consumption situation.
Factory reset
After Z810B joins the network, it will save its assigned network address. If you want to join a new network, you need to restore the original factory settings first. After pressing and holding the binding key for 15 seconds, the icon will flash (During the period, the
icon will flash 3 times, including once every 3 seconds, once every 10 seconds, and once every 15 seconds), and then release the binding key. After releasing the button, short press the function button within 2 seconds to restore the factory settings, and the LCD value area will display:
It means that the original factory settings are restored successfully, the device will automatically restart and can rejoin the network.
Erase power information
The energy information detected by Z810B will be stored in the EEPROM memory, and the energy information will not be erased when the factory value is restored, and the energy information can be erased by the following methods:
(a) After pressing and holding the bound key for 20 seconds, the icon will flash once (4 times during the period, including once in 3 seconds, once in 10 seconds, once in 15 seconds, and once in 20 seconds) then release the bound key.
(b) Short press the function key within 2 seconds after releasing it to make Z810B erase the power information, and the LCD value area will display the power information as 0, as shown in the figure
Clusters of Home Automation for Z810B
- End Point(s): 0x01
- Device ID: Mains Power Outlet (0x0009)
- Cluster ID supported by EndPoint
Cluster ID for Z810B Server Side Client Side EP 0x01 (Device ID: Mains Power Outlet (0009)) Basic (0x0000) None Identify (0x0003) Groups (0x0004) Scenes (0x0005) On/Off (0x0006) Commission (0x0015) Diagnostics (0x0B05) Simple Metering (0x0702) Electrical Measurement (0x0B04) * Simple Metering (0x0702): Current (unit mA), Voltage (unit V), Power (unit W) and Energy (unit KWh).
- The relevant attribute definitions of each Cluster
- Attributes of the Basic Device Information attribute set
Identifier Name Type Range Access Default Mandatory/ Optional 0x0000 ZCLVersion 8-bitUnsigned integer 0x00–0xff Read Only 0x03 M 0x0001 ApplicationVersion 8-bit Unsignedinteger 0x00–0xff Read Only 0x1F O 0x0002 StackVersion 8-bit Unsignedinteger 0x00–0xff Read Only 0x35 O 0x0003 HWVersion 8-bit Unsignedinteger 0x00–0xff Read Only 0x0B O 0x0004 ManufacturerName Characterstring 0 – 32Bytes ReadOnly netvox O 0x0005 ModelIdentifier Characterstring 0 – 32Bytes ReadOnly Z810BE3R O 0x0006 DateCode Characterstring 0 – 16Bytes ReadOnly 20140706 O 0x0007 PowerSource 8-bitEnumeration 0x00–0xff ReadOnly 0x01 M 0x0010 LocationDescription Characterstring 0 – 16Bytes Read/Write Emptystring O 0x0011 PhysicalEnvironment 8-bitEnumeration 0x00–0xff Read/Write 0x00 O 0x0012 DeviceEnabled Boolean 0x00–0x01 Read/Write 0x01 O - Attributes of the identify server cluster
Identifier Name Type Range Access Default Mandatory/ Optional 0x0000 IdentifyTime 16-bitUnsigned integer 0x0000–0xffff Read 0x0000 M - Attributes of the Group server cluster
Identifier Name Type Range Access Default Mandatory/ Optional 0x0000 NameSupport 8-bit bitmap x0000000 Read Only 10000000 M - Attributes of the Scene server cluster
Identifier Name Type Range Access Default Mandatory/ Optional 0x0000 SceneCount Unsigned8-bit integer 0x00 – 0xff Read Only 0x00 M 0x0001 CurrentScene Unsigned 8-bitinteger 0x00 – 0xff Read Only 0x00 M 0x0002 CurrentGroup Unsigned 16-bitinteger 0x0000 –0xfff7 Read Only 0x00 M 0x0003 SceneValid Boolean 0x00 – 0x01 Read Only 0x00 M 0x0004 NameSupport 8-bit bitmap x0000000 Read Only 10000000 M - Attributes of the On/Off server cluster
Identifier Name Type Range Access Default Mandatory/ Optional 0x0000 OnOff Boolean 0x00–0x01 Read Only 0x00 M - Attributes of the Commissioning Information
Identifier Name Type Range Access Default Mandatory/ Optional 0x0000 Short address Unsigned16-bit integer 0x0000 –0xfff7 Read/Write 0 O 0x0001 Extended pan id IEEE_ADDR ESS 0x0000000000000000 –0xffffffffffff fffe Read/Write FFFFFFFFF FFFFFFF M 0x0002 Pan id Unsigned 16-bitinteger 0x0000–0xFFFF Read/Write 0xFFFF O 0x0003 Channel mask
BITMAP32
Any valid IEEE 802.15.4channelmask Read/Write 0x07FFF800
M 0x0006 Startup control 8-bit Enumeration 0x00 – 0x03 Read/Write 0x03 M 0x0010 Trust center address IEEE_ADDR ESS Any valid IEEEAddress Read/Write 0x0000000000000000 M 0x0011 Trust center master key SECURITY_ KEY Any 128-bit value Read/Write 0000000000 M 0x0012 Network key
SECURITY_ KEY Any 128-bit value Read/Write 5A 69 67 4265 65 416C 6C 6961 6E 6365 30 39 M 0x0013 Use insecure join BOOLEAN FALSE/TRUE Read/Write 0x1 M 0x0014 Preconfigured link key SECURITY_ KEY Any 128-bit value Read/Write 5A 69 67 4265 65 416C 6C 6961 6E 6365 30 39 M 0x0015 Network key sequence number Unsigned 8-bitinteger 0x00-0xFF Read/Write 0x00 M 0x0016 Network key type 8-bit Enumeration Any valid key typevalue Read/Write 0x05 M 0x0017 Network mananger address Unsigned16-bit integer Any validnetwork address Read/Write 0x0000 M 0x0020 Scan attempts Unsigned 8-bitinteger 0x01-0xFF Read/Write 0x05 M 0x0021 Time between scans Unsigned16-bit integer 0x0001–0xFFFF Read/Write 0x0064 M 0x0022 Rejoin interval Unsigned 16-bitinteger 0x0001 -MaxRejoinI nterval Read/Write 0x003C M 0x0023 Max rejoin interval Unsigned 16-bitinteger 0x0001–0xFFFF Read/Write 0x0E10 M 0x0030 Indirect poll rate Unsigned 16-bit integer 0x0000–0xFFFF Read/Write 0x0000 M 0x0031 Parent retry threshold Unsigned 8-bit integer 0x00-0xFF Read/Write 0x00 M 0x0040 Concentrator flag BOOLEAN FALSE/TR UE Read/Write 0x00 M 0x0041 Concentrator radius Unsigned 8-bit integer 0x00-0xFF Read/Write 0x0F M 0x0042 Concentrator discovery time Unsigned 8-bit integer 0x00-0xFF Read/Write 0x00 M
Product attributes and custom instruction description
- The Cluster used by Z810B refers to the Cluster ID (0x0702) and Electrical Measurement Cluster ID (0x0B04) used by Simple Metering in SE, and in the Cluster ID (0x0702), NETVOX has customized the attributes of current, voltage, power, and electric energy
Cluster ID (0x0B04):
- The Attribute ID used for the current attribute is: 0x0508, and the voltage attribute is 0x0505.
- The power attribute uses Attribute ID: 0x050B, and the power factor attribute is 0x0510.
Cluster ID (0x0702):
- The custom current attribute uses Attribute ID: 0xE000, and the custom voltage attribute is 0xE001.
- The custom power attribute uses Attribute ID: 0xE002, and the custom electric energy attribute is 0xE003.
- The attribute CurrentSummationDeliver whose AttributeID is 0x0000 corresponds to the electric energy attribute 0xE003.
- Electric energy ATTRID = 0xE003 (or 0x0000), the unit is wh. power ATTRID = 0xE002, the unit is w. Current ATTRID = 0xE000, the unit is mA; Voltage ATTRID = 0xE001, the unit is V
Custom directive
The command to erase the current power information is: 0xE0. The command format is:
(clustered: 0x0702, Action: 0x00)
Bits: 8 | 16 | 8 | 8 | 8 |
Frame control | Manufacturer code | Transaction Sequencenumber | Command identifer | Frame payload |
Action | ||||
0x05 | 0x109F | 0xE0 | 0x00 |
Load Characteristics
Rated Load (AC) | Max. Load with LEDs | Max. Inductive Load (cosφ=0.4) | Max. Load with Electric Motors | Overload Protection with Auto PowerCutoff |
20A / 250V | 100W / 1 LED | 5A / 250V | 2HP / 250V | Yes |
Installation Method
This product does not have a waterproof function. After the network configuration is completed, please place it indoors.
Notice:
- When the detected current exceeds the measurement range (20A), the device will automatically disconnect the load within 2 seconds after the detection, and check whether the Bit1 (Current OverLoad) of the attribute ACAlarmsMask is 1. If it is 1, the device will sent an alarm, 0 for no alarm. AlarmCluster = 0x0B04, AlarmCode = 0xF0; network light (using red light) flashes 10 times (10,250,250)
- If the storage chip of Z810B is AT2401, it will save it every 30 seconds, if it is AT2402, it will save it every 10s, and other high-capacity storage such as AT2404/08 will save it every 1 second, so the data within 30/10/1 second will be lost due to power failure.
Important Maintenance Instruction
As the device is not water proof it is recommended to keep the device in a dry place. Liquid and heavy moisture contains minerals that may oxidize the electronic circuitry. In case of liquid spill, please leave the device to completely dry before storing or using.
- Do not use or store the device in a dusty area. Dust may cause electronic parts to destroy.
- Do not use or store the device in an over heated place. Store in a hotter temperature than the suggested maximum temperature may shorten the life span of the device; and may damage the battery and causing the housing to deform.
- Do not use or store the device in a very cold place than the suggested minimum temperature. The water can be condensed inside the device when moving to an area that is higher in temperature. This can severely damage the PCB board and circuitry. This may shorten the life span of the device; damage the battery and cause the housing to deform.
- Do not throw or strongly vibrate the device. This may damage connectivity of the electronic parts and other sensitive components on the PCB board.
- Do not use any strong chemical or washing to cleanse the device.
- Do not use any coloring materials on any removable parts which my cause poor connections and may keep the device from function properly.
All the above applies to the purchased products, battery and other packaged items. If any unusable or damaged items are found please return the product to your nearest authorized repairing center.
Documents / Resources
![]() |
netvox Z810B Wireless Load Control 2T With Power Energy Current Voltage Meter And LCD [pdf] User Manual Z810B Wireless Load Control 2T With Power Energy Current Voltage Meter And LCD, Z810B, Wireless Load Control 2T With Power Energy Current Voltage Meter And LCD, Power Energy Current Voltage Meter And LCD, Voltage Meter And LCD, Meter And LCD |