Board Assembly Part Number(s)

Board Assembly Part Number(s) Description
153034G-011L through 153034G-921L NI PXIe-8135, CORE I7-3610QE, 2.3GHZ CONTROLLER

Manufacturer

National Instruments

Volatile Memory

Type1

Size User Accessible/ System Accessible2 Battery Backup? Purpose Method of Clearing3

DDR3 SDRAM

4+ GB Yes/Yes No Controller RAM

Cycle Power

CMOS RAM 256 B Yes/Yes Yes PCH CMOS

Remove CMOS battery

Non-Volatile Memory

Type

Size User Accessible/ System Accessible Battery Backup? Purpose Method of Clearing
SPI Flash 1 Mbit No/Yes No Ethernet port firmware

None Available to User

CPLD

1200 LUTs No/No No Power sequence / watchdog None Available to User
EEPROM 2 Kbits No/No No GPIB configuration

None Available to User

SPI Flash

32 Mbits No/Yes No Management Engine None Available to User
SPI Flash 32 Mbits No/Yes No BIOS configuration

None Available to User

CPLD

192 Macro Cells No/No No PXI Trigger router None Available to User
EEPROM 256 Kbits No/No No PLX switch configuration

None Available to User

Media Storage

Type

Size User Accessible/ System Accessible Battery Backup? Purpose Method of Clearing
Hard Drive 250+ GB Yes/Yes No Primary Disk Drive

Remove from controller4

  1. Calibration constants that are stored in device EEPROMs include information for the device’s full operating range. Calibration constants do not maintain any unique data for specific configurations at which the device is used unless otherwise specified.
  2. Items are designated No for the following reason(s):
    a) Hardware changes or a unique software tool from National Instruments are required to modify contents of the memory listed.
    b) Hardware-modifying software tools are not distributed to customers for any personal access or customization, also known as non-normal use.
  3. The designation None Available to User indicates that the ability to clear this memory is not available to the user under normal operation. The utilities required to clear the memory are not distributed by National Instruments to customers for normal use.
  4. Since a hard drive cannot be cleared, to declassify a system containing a PXI embedded controller, the controller’s hard drive must be removed as part of the declassification procedure. This can be done by removing the controller from the system or removing the hard drive from the controller during declassification. Alternatively, the hard drive can be permanently removed from the controller and a Compact PCI (c PCI) hard drive carrier/interface can be used to provide an easily removable, bootable hard drive.

Terms and Definitions

User Accessible Allows the user to directly write or modify the contents of the memory during normal instrument operation.

System Accessible Does not allow the user to access or modify the memory during normal instrument operation. However, system accessible memory may be accessed or modified by background processes. This can be something that is not deliberate by the user and can be a background driver implementation, such as storing application information in RAM to increase speed of use.

Cycle Power The process of completely removing power from the device and its components. This process includes a complete shutdown of the PC and/or chassis containing the device; a reboot is not sufficient for the completion of this process.

Volatile Memory Requires power to maintain the stored information. When power is removed from this memory, its contents are lost.

Non-Volatile Retains its contents when power is removed. This type of memory typically contains calibration or chip configuration information, such as power up states.

Customers Support

Contact: 866-275-6964
support@ni.com

Phone Icon  1-800-915-6216

Icon www.apexwaves.com

Email Icon sales@apexwaves.com

All trademarks, brands, and names are the property of their respective owners.

LogoNATIONAL INSTRUMENTS Logo

Documents / Resources

NATIONAL INSTRUMENTS PXIe-8135 Embedded Controller [pdf] User Guide
153034G-011L through 153034G-921L, PXIe-8135, PXIe-8135 Embedded Controller, Embedded Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *