LPC-60 Series 60W Single
Output Switching Power Supply
User Manual60W Single Out put Switching Power Supply
LPC-60 series
LPC-60 Series 60W Single Output Switching Power Supply
Features :
- Constant current design
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Over voltage
- Cooling by free air convection
- Fully encapsulated with IP67 level (Note.7)
- Fully isolated plastic case
- Class II power unit, no FG
- Class 2 power unit
- Pass LPS
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)(Note.10)
- 100% full load burn-in test
- Low cost, high reliability
- 2 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL | LPC-60-1050 | LPC-60.1400 | LPC-60.1750 | |
OUTPUT | RATED CURRENT | 1050mA | 1400mA | 1750mA |
DC VOLTAGE RANGE | 9 – 48V | 9 – 42V | 9 – 34V | |
RATED POWER | 50.4W | 58.8W | 59.5W | |
RIPPLE & NOISE (max.) Note.2 | 200mVp-p | 200mVp-p | 200mVp•p | |
VOLTAGE TOLERANCE Note.3 | ±5.0% | |||
CURRENT ACCURACY | ±5.0% | |||
LINE REGULATION | ±1.0% | |||
LOAD REGULATION | ±2.0% | |||
SETUP, RISE TIME Note.6 | 500ms. 120ms / 230VAC 500ms, 120ms / 115VAC at full load | |||
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load | |||
INPUT | VOLTAGE RANGE Note.4 | 90 – 264VAC 127 – 370VDC | ||
FREQUENCY RANGE | 47 – 63Hz | |||
EFFICIENCY (Typ.) | 87% | I85% | 187% | |
AC CURRENT (Typ.) | 1.2A/115VAC 0.7Al230VAC | |||
INRUSH CURRENT(Typ.) | COLD START 60A(twidth.7540us measured at 50% (peak) at 230VAC | |||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type 13) / 6 units (circuit breaker of type C) at 230VAC | |||
LEAKAGE CURRENT | 0.25mA/ 240VAC | |||
PROTECTION | OVER VOLTAGE | 50.4 – 60V | I 44.1 – 56.7V | 1 39.1 – 45.9V |
Protection type : Shut off olp voltage. clamping by TVS diode | ||||
ENVIRONMENT | WORKING TEMP. | -30 – +70°C (Refer to iterating Curve’) | ||
WORKING HUMIDITY | 20 – 90% RH noncondensing | |||
STORAGE TEMP., HUMIDITY | •0 – +80°C. 10 – 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/°C (0 – 50°C) | |||
VIBRATION | 10 – 500Hz. 2G 10min./I cycle. period for 60min. each along X, Y, Z axes | |||
SAFETY & EMC | SAFETY STANDARDS | UL1310. CAN/CSA C22.2 No. 223•M91(for LPC-60-I 750 only). BIS 1515885(except for LPC-60.1750), EAC TP TC 004, IP67, IEC62368•1 . BS EN/EN62368.I approved | ||
WITHSTAND VOLTAGE | I/P-0/P:3KVAC | |||
ISOLATION RESISTANCE | 1/P-0/P:>100M Ohms / 500VDC / 25°C/ 70% RH | |||
EMC EMISSION | Compliance to BS EN!EN55032 (CISPR32) Class B. BS EN/EN61000-3-2 Class A, BS ENIEN61000-3-3, EAC TP TC 020 | |||
EMC IMMUNITY | Compliance to BS EN/EN6I 0004-2,3,4,5.6.8.11 , BS EN1EN55035, light industry level. EAC TP TC 020 | |||
OTHERS | MTBF | 5269.3K hrs min. Telcordia SR-332 (Bellcore) : 567.2K hrs min. MIL-HDBK-217F (25°C) | ||
DIMENSION | 162.5’42.5’32mm (L’W’H) | |||
PACKING | 0.4Kg; 32pcs113.8Kg10.63CUFT | |||
NOTE | 1.AI parameters NOT specially mentioned are measured at 230VAC input, rated load and 25`C of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12′ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance : includes set up tolerance, line regulation and load regulation. 4.Derating may be needed under low input voltage. Please check the static characteristics for more details. 5.The power supply is considered as a component that will be operated I-1 combination with final equipment Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.corriftUp4oad/PDREMI_statement_en.pdf) 6.Length of set up time is measured at first coed start. Tuming ON/OFF the power supply may lead to increase of the set up time. 7.Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute. 8.The ambient temperature derating of 3.5C/1000m with fanless models and of SC/1000m with fan models for operating altitude higher than 2000m(6501:10. 9.For any application note and IP water proof function installation caution, please refer our user manual before using. httpslAwsw.meanwell.com/Up4oad/PDFLED_EN.pdf 10.This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.) x Product Liability Disclaimer : For detailed information, please refer to httpsfAwww.meanwelloomiserviceDisciakner.aspx |
Mechanical Specification
Recommend Mounting Direction
Block Diagram
Derating Curve
Static Characteristics
http://www.meanwell.com.cn/Upload/PDF/LED_EN.pdf
Downloaded from Arrow.com.
Documents / Resources
![]() |
MEAN WELL LPC-60 Series 60W Single Output Switching Power Supply [pdf] User Manual LPC-60 Series 60W Single Output Switching Power Supply, LPC-60 Series, 60W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |
![]() |
MEAN WELL LPC-60 Series 60W Single Output Switching Power Supply [pdf] Owner's Manual LPC-60 Series 60W Single Output Switching Power Supply, LPC-60 Series, 60W Single Output Switching Power Supply, Single Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |