MC PROPELLER M17 Open Flow Meter
Specifications
- Model: M17 Open Flow Meter
- Standard: American Water Works Association Standard C704-02
Product Description
The MC Propeller Model M17 open-flow meters are designed to measure flow in canal outlets, discharge and inlet pipes, irrigation turnouts, and similar installations.
Features
- Construction: Durable materials
- Impellers: High-quality impellers for accurate measurements
- Bearings: Various bearing options available for different needs
- Register: Digital registers and mechanical registers available
Product Usage Instructions
Installation
Mount the Model M17 on a headwall, standpipe, or suitable structure ensuring the propeller is positioned in the center of the discharge or inlet pipe.
Pipe Run Requirements
For meters without straightening vanes, a straight run of full pipe length of ten pipe diameters upstream and one diameter downstream is recommended. Meters with optional straightening vanes require at least five pipe diameters upstream.
FAQ
Q: What are the typical applications of the Model M17 Open Flow Meter?
A: The Model M17 is commonly used to measure flow in canal outlets, discharge and inlet pipes, irrigation turnouts, and similar installations.
Q: What bearing options are available for the Model M17?
A: The bearing options include Standard, Marathon, SS316, SS316 Marathon, SS316 Ceramic.
Q: What output options are available for the Model M17?
A: Output options include No Outputs, Open Collector Pulse, 4-20mA Analog Only, and 4-20mA Analog + Open Collector Pulse.
DESCRIPTION
- Model M17 open flow meters are designed to measure the flow in canal outlets, discharge and inlet pipes, irrigation turnouts, and other similar installations.
- Model M17 meets or exceeds the American Water Works Association Standard C704-02.
FEATURES
Construction
- Constructed of stainless steel, the meter incorporates bronze mounting brackets that permit simple installation and removal.
Impellers
- Impellers are manufactured of high-impact plastic, designed to retain both shape and accuracy over the life of the meter.
- Each impeller is individually calibrated at the factory to accommodate the use of standard McCrometer registers, and since no change gears are necessary, the M17 can be field-serviced without the need for factory recalibration.
Bearings
- Factory lubricated, stainless steel bearings are used to support the impeller shaft.
- The sealed bearing design limits the entry of materials and fluids into the bearing chamber providing maximum bearing protection.
Register
- An instantaneous flow rate indicator is standard and available in gallons per minute, cubic feet per second, liters per second, and other units.
- The register is driven by a flexible steel cable encased within a protective, self-lubricating vinyl liner.
- The die-cast aluminum register housing protects both the register and cable drive system from moisture while allowing a clear reading of the flowrate indicator and totalizer.
Typical Applications
- The McCrometer propeller meter is the most widely used flowmeter for municipal water and wastewater applications as well as agricultural and turf irrigation measurements.
Typical applications include:
- Water and wastewater management
- Canal laterals
- Gravity turnouts from underground pipelines
- Sprinkler irrigation systems
- Golf course and park water management
Part Numbers, Digital Registers
Part Numbers, Mechanical Registers
INSTALLATION
Model M17 must be mounted on a headwall, standpipe, or other suitable structure so that the propeller is located in the center of the discharge or inlet pipe.
PIPE RUN REQUIREMENTS
- A straight run of full pipe the length of ten pipe diameters upstream and one diameter downstream of the meter is recommended for meters without straightening vanes.
- Meters with optional straightening vanes require at least five pipe diameters upstream of the meter.
SPECIFICATIONS
Performance | |
Accuracy / Repeatability | • ±2% of reading guaranteed throughout the full range
• ±1% over reduced range • Repeatability 0.25% or better |
Range | 10” to 72” |
Maximum Temperature | (Standard Construction) 160°F constant |
Materials | |
Bearing Assembly | The impeller shaft is 316 stainless steel. Ball bearings are 440C stainless steel |
Drop Pipe | 304 stainless steel construction |
Bearing Housing | • Impeller shaft: 316 stainless steel
• Ball bearings: 440C stainless steel |
Magnets | Permanent type. Alnico. |
Register | An instantaneous flow rate indicator and a six-digit straight-reading register are standard. The register is hermetically sealed within a die-cast aluminum case. This protective housing includes a domed acrylic lens and a hinged lens cover with a locking hasp. |
Impeller | Impellers are manufactured of high-impact plastic, retaining their shape and accuracy over the life of the meter. |
Options | |
• Marathon bearing assembly for higher than normal flowrates 4” and larger
• Digital register available in all sizes of this model • A complete line of flow recording/control instrumentation • Extra wall brackets • Canopy boot |
DIMENSIONS
IMPORTANT Open flow meters 30” and larger require a FlowCom register.
M1700 | DIMENSIONS | |||||||||||||
Meter Size (inches) | 10 | 12 | 14 | 16 | 18 | 20 | 24 | 30 | 36 | 42 | 48 | 54 | 60 | 72 |
Maximum Flow U.S. GPM | 1800 | 2500 | 3000 | 4000 | 5000 | 6000 | 8500 | 12500 | 17000 | 22000 | 30000 | 36000 | 42000 | 60000 |
Minimum Flow U.S. GPM | 125 | 150 | 250 | 275 | 400 | 475 | 700 | 1200 | 1500 | 2200 | 2800 | 3500 | 4000 | 6000 |
Max. Flow w/ Marathon Bearing | 2700 | 3750 | 4500 | 6000 | 7500 | 9000 | 12750 | 18750 | 25500 | 37500 | 45000 | 54000 | 63000 | 90000 |
Approx. Head Loss in Inches at Maximum Flow |
3.75 |
2.75 |
2.00 |
1.75 |
1.50 |
1.20 |
1.00 |
.52 |
.40 |
– |
– |
– |
– |
– |
Standard Dial Face (GPM/Gal) * | 3K/
1000 |
4K/
1000 |
6K/
1000 |
8K/
1000 |
10K/
1000 |
10K/
10K |
15K/
10K |
15K/
10K |
30K/
10K |
35K/
10K |
Consult factory | |||
A * (in feet) | 5 | 5 | 5 | 5 | 6 | 6 | 6 | 6 | 6 | 10 | 10 | 10 | 10 | 10 |
B Regular Brackets (inches) | 2 13/16 | 4 3/8 | ||||||||||||
B Universal Brackets (inches) | 3 15/16 | – | ||||||||||||
C (inches) | 14 3/4 | 14 3/4 | 14 3/4 | 14 3/4 | 17 | 17 | 17 | 17 | 17 | 21 1/2 | 21 1/2 | 21 1/2 | 21 1/2 | 21 1/2 |
Approx. Shipping Weight Crated – lbs. | 120 | 120 | 120 | 120 | 140 | 140 | 140 | 140 | 140 | 250 | 250 | 250 | 250 | 250 |
Overall Height (ft) | 5 | 5 | 5 | 5 | 6 | 6 | 6 | 6 | 6 | 10 | 10 | 10 | 10 | 10 |
Standard lengths, optional lengths in 12” increments per customer order
REGISTERS
Mechanical Register
- The instantaneous fl owrate indicator is standard and available in gallons per minute, cubic feet per second, liters per second, and other units.
- The register is driven by a flexible steel cable encased within a protective vinyl liner. The register housing protects both the register and cable drive system from moisture while allowing a clear reading of the flow rate indicator and totalizer.
Digital Register
- The optional FlowCom digital register displays a flowmeter’s flow rate and volumetric total. Available are four optional outputs: 4-20mA loop, open collector, optically isolated, and contact closure.
- Unique units of measurement for rate, total, 4-20mA, and pulse outputs. The FlowCom can be fitted to any new or existing McCrometer propeller flowmeter. The FlowCom also features a built-in data logger.
Wireless Telemetry
- The optional FlowConnect is designed specifically for wireless telemetry via either satellite or cellular data service. A manual meter reading is never required.
- It uses either the mechanical register or the digital register (both shown above).
- You can determine how often readings are made and transmitted to the cloud database, which you can view on a PC or a cell phone.
- The viewing utility provides data tools that can analyze flow rate, consumption, and possible anomalies in an irrigation system.
- Copyright © 2024 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer.
- Any published pricing, technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
- 3255 WEST STETSON AVENUE
- HEMET, CALIFORNIA 92545 USA
- TEL: 951-652-6811
- 8002202279
- FAX: 9516523078 www.mccrometer.com
Documents / Resources
![]() |
MC PROPELLER M17 Open Flow Meter [pdf] Instruction Manual 10, 12, 14, 16, 18, 20, 24, 30, 36, 42, 48, 54, 60, 72, M17 Open Flow Meter, M17, Open Flow Meter, Flow Meter, Meter |