JBC DME-9A 100V 4-Tool Control Unit Instruction Manual
JBC DME-9A 100V 4-Tool Control Unit Instruction Manual

Packing List

Packing List
Tool
Control Unit: 1 unit

Power Cord
Power Cord: 1 unit
Ref. 0024077 (100V)
0023717 (120V)
0024080 (230V)

Manual
Manual: 1 unit
Ref. 0031931

Features

DME works simultaneously with up to 4 tools, 1 module and 1 pedal for each tool (peripheral module for each tool needed).
Product Overview

Connection Example
Connection Example Overview

Compatibility

Combine the equipment that best suit your soldering or desoldering needs.

Marked with means pedals P405 and P005 cannot be connected directly to JBCs control units DDE and DME. A module must be used and the pedals are connected to the module.

Modular System Modals Pedals
Control Unit Stand Tool Cartridge Range MSE MVE MNE P005 P305 P405
DDE DME ADS T210 C210
T245 C245
T470
DNS T210N C210
T245N C245
APS AP250 C250
AMS AM120 C120
PA120
ATS AT420 C420
HTS HT420
DSS DS360 C360
DRS DR560 C560
DTS DT530 D530

Work Screen
DME offers an intuitive user interface which provides quick access to the station parameters.
Default PIN: 0105

Product Overview

Troubleshooting
Station troubleshooting available on JBC’s web page:
www.jbctools.com/troubleshooting-soldering-station.html

Main Menu Screen

Product Overview

Utilities Submenu

Graphics
Graphics
It provides detailed graphics of tip temperature and power delivery in real-time during solder joint formation for analysis purposes. This helps you decide how to adjust your process or which tip to use to obtain the best quality soldering.

Files
Files
Export graphics
Insert a USB flash drive into the USB-A connector to save your soldering process in CSV format.

Video
Video
Play videos
Enables to play video files from a USB device as long as it is in AVI format and 320x240px.
USB Connection

Microscope
Microscope
Provides the possibility to connect a microscope* by USB connection to the station. The image will be shown on the station display.
compatible with: Dino Lite AM2111 and AM2011

Calculator
Calculator
Provides calculator environment and function.

Convert
Convert
Enables to convert, for example, ºC values into ºF values.

System notifications
The following icons will be displayed on the screen status bar.

USB Icon USB flash drive is connected.
Laptop Icon Station is controlled by a PC.
controlled Icon Station is controlled by a robot. downloaded to the station.
Recycle Icon Station software update. Press INFO to start the process.
Warning Icon Warning. Press INFO for failure description.
Error Icon Error. Press INFO for failure description, the type of error and how to proceed.

MSE / Pedal Initial Setup

Peripherals
Peripherals
After connecting the electric desoldering module (MSE-A), a popup window is opened.

  1. To configure your Electric Suction Module press Setup in the popup window.
    Pedal Initial Setup
  2. Select the module from the list of peripheral connections. Remember your first connection is denoted as “a”, the second being “b”, etc. (e.g. MS_a, MS_b,…). Do the same with the pedal (e.g. PD_a,…)
    Pedal Initial Setup
  3. Select the port of the tool you want to link to the peripheral.
  4. Press Menu Home Icon or Back icon to save changes. Once set up, the module settings can be changed by entering the Peripherals Menu

Simultaneous Ports Control
See the information for all ports in real time when pressing the tool image on the Work display.
Simultaneous Ports Control

Operation

JBC’s Most Efficient Soldering System
Our revolutionary technology is able to recover tip temperature extremely quickly. It means the user can work at a lower temperature and improve the soldering quality. The tip temperature is further reduced thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip.

  1. Work
    Installation Soldering System
    When the tool is lifted from the stand the tip will heat up to the selected temperature.
  2. Sleep
    Installation Soldering System
    When the tool is in the stand, the temperature falls to the present sleep temperature.
  3. Hibernation
      Installation Soldering System
    After longer periods of inactivity, the power is cut off and the tool cools down to room temperature.

Work Temperature:
Change from 90 to 450 ºC by tapping or on the screen.
Temperature Levels:
Tap Menu > Tools > Temperature levels and set them “ON”. The levels can be modified tapping Menu > Tools > Set temperature levels.
Work Temperature

Sleep Delay:
Tab Menu > Tools and select Sleep Delay to set the delay between 0 and 60 min or No Sleep.
Sleep Temperature:
Tab Menu > Tools and select Sleep Temperature to modify its value.
Sleep Delay

Hibernation Delay:
Tab Menu > Tools and select Hibernation Delay to change from 0 to 60 min or No Hibernation.
Hibernation Delay

  • Tap “Menu” (1) on the work screen to access to the main menu.
  • Tap “Home” (2) to go back to work screen.
  • Tap “Tools” (3) to access to configurations.

USB Connector and Firmware Update

Download: JBC Firmware Update File
Download the JBC firmware update file from www.jbctools.com/software.html, which contains the latest update package. Extract the .jape file to the root folder of a USB-A pen drive (FAT32), preferably with no other files
USB Connector and Firmware Update

Connection: USB-A Pen Drive to Control Unit
Connect the USB-A pen drive which contains the latest update file and the update notification to the control unit.
This symbol Recycle Icon will be displayed automatically.
USB Connector and Firmware Update
If the DME control unit does not detect the USB pen drive, please use a pen drive partitioning software.

Installation: JBC Firmware Update File

 JBC Firmware Update File
Press “Install” on the pop-up window. If is not displayed, tap Recycle Icon on the notification.

Updating Process
During the updating process do not turn off the control unit, it may turn on and off automatically. The installation finishes when the updating bar is completed and the work screen is displayed.
Updating Process

The work screen will be displayed after confirming the “Welcome” pop-up.
If the process stops for a long time (over 30 min), reset the station and wait until the installation is fully completed.

Checking Firmware Version

Check that the new firmware has been installed successfully by means of the following steps:
Checking Firmware Version
Checking Firmware Version

Select “Information” (3) and then press (4) to check the firmware version.
Checking Firmware Version
Checking Firmware Version

Maintenance

Before carrying out maintenance or storage, always allow the equipment to cool.

  • Clean the station display with a glass cleaner or a damp cloth.
  • Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.
  • Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool and establish its status.
  • Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation. Rusty and dirty surfaces reduce heat transfer to the solder joint.
  • Periodically check all cables and tubes.
    Product Overview
    1. Pull off the fuse holder and remove the fuse. If necessary use a tool to lever it off.
      Fuse Holder
    2. Insert the new fuse into the holder and return it to the station.
      Fuse holder
  • Replace any defective or damaged pieces. Use original JBC spare parts only.
  • Repairs should only be performed by a JBC authorized technical service.

Safety

Warning Icon It is imperative to follow safety guidelines to prevent electric shock injury, fire or explosion.

  • Do not use the units for any purpose other than soldering or rework. Incorrect use may cause a fire.
  • The power cord must be plugged into approved bases. Be sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.
  • Do not work on electrically live parts.
  • The tool should be placed in the stand when not in use in order to activate the sleep mode. The soldering tip or nozzle, the metal part of the tool and the stand may still be hot even when the station is turned off. Handle with care, including when adjusting the stand position.
  • Do not leave the appliance unattended when it is on.
  • Do not cover the ventilation grills. Heat can cause inflammable products to ignite.
  • Avoid flux coming into contact with skin or eyes to prevent irritation.
  • Be careful with the fumes produced when soldering.
  • Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
  • Utmost care must be taken with liquid tin waste which can cause burns.
  • This appliance can be used by children over the age of eight and also people with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning the use of the appliance and understand the hazards involved. Children must not play with the appliance.
  • Maintenance must not be carried out by children unless supervised.

Specifications

DME
4-Tool Control Unit
Ref. DME-1A 120V 50/60Hz. Input fuse: T-3.5A. Output: 23.5V
Ref. DME-2A 230V 50/60Hz. Input fuse: T-3.15A. Output: 23.5V
Ref. DME-9A 100V 50/60Hz. Input fuse: T-8A. Output: 23.5V

  • Peak Power (Tool): 150W per tool
  • Selectable Temperature: 90 – 450 °C / 190 – 840 °F
  • Idle Temp. Stability (still air): ±1.5ºC / ±3ºF Meets and exceed IPC J-STD-001F
  • Temp Accuracy: ±3% using reference cartridge
  • Temp Adjustment: ±50ºC / ±90ºF Through station settings menu
  • Tip to Ground Voltage/Resistance: Meets and exceeds ANSI/ESD S20.20 and IPC J-STD-001F
  • Ambient Operating Temp: 10 – 50 ºC / 50 – 122 ºF
  • Connections: USB-A: Firmware Update, Grafics and Profiles, Dino-Lite USB Microscope (models AM2011, AM2111)
    USB-B: PC Communication
    RJ12: Fume Extractor/Peripherals/Robot
  • Control Unit Dimensions / Weight: 232 x 148 x 120 mm / 4.57 kg (L x W x H) 9.13 x 5.83 x 4.72 in / 10.08 lb
  • Total Package Dimensions / Weight: 258 x 328 x 208 mm / 4.97 kg (L x W x H) 10.16 x 12.91 x 8.19 in / 10.96 lb

Complies with CE standards.
ESD safe.

Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labor.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/ within 30 days of purchase.
If you register, you will receive e-mail notifications about new software updates for your registered product.

Disposal Icon This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.
www.jbctools.com

CE Icon EAC Icon UK CA Logo

JBC Logo

Documents / Resources

JBC DME-9A 100V 4-Tool Control Unit [pdf] Instruction Manual
DME-9A, DME-9A 100V 4-Tool Control Unit, 100V 4-Tool Control Unit, 4-Tool Control Unit, Control Unit

References

Leave a comment

Your email address will not be published. Required fields are marked *