IDSWITCH LMP1218-PWM Master Power Unit

IDSWITCH-LMP1218-PWM-Master-Power-Unit -PRODUCT

General Safety Instruction

Safety Instruction
As dangerous voltages and high temperature exist within the LMP1218-PWM Master Power Unit, only qualified and authorized maintenance personnel are permitted to open and repair it. Please make sure the unit is turned off before open and repair it.
This manual contains information concerning the installation and operation of LMP1218-PWM Master Power Unit. All relevant parts of the manual should be read prior to commencing the installation. Please follow the local stipulation meantime.
Any operation against safety requirement or against design, manufacture, safety standard, and are out of the manufacturer warranty.

General Precaution

  1. Do not expose to dust, rain, snow or liquids of any type,it is designed for indoor use. DO NOT block off ventilation, otherwise the LMP1218-PWM Master Power Unit would be overheating.
  2. To avoid fire and electric shock,make sure all cables selected with right gauge and being connected well. Smaller diameter and broken cable are not allowed to use.
  3. Please do not put any inflammable goods near to this unit.
  4. Never place this unit directly above batteries, gases from a battery will corrode and damage LMP1218-PWM Master Power Unit.
  5. Do not place battery over LMP1218-PWM Master Power Unit.

Precaution regarding battery operation

  1. Use plenty of fresh water to clean in case battery acid contacts skin, clothing, or eyes and consult with doctor as soon as possible.
  2. The battery may generate flammable gas during charging. NEVER smoke or allow a spark or flame in vicinity of a battery.
  3. Do not put the metal tool on the battery, spark and short circuit might lead to explosion.
  4. REMOVE all personal metal items such as rings, bracelets, necklaces, and watches while working with batteries. Batteries can cause short-circuit current high enough to make metal melt, and could cause severe burns.

LMP1218-PWM INTRODUCTION

Features

  • Smart battery charger 12V18A
  • Active PFC charging
  • 16 Fused DC outputs, including water pump and lighting central control.
  • Battery charging relay 12V 30A
  • Battery Low Voltage Protection
  • Built in Main Switch to isolate the battery when in storage
  • Support external remote Main switch
  • Control one water pump with two tank probes
  • Solar charger controller (PMW), 15A

LED Display
Table 1 LED indication

NO. LED Color Status Description
1 CHG Green ON Battery charged
Flashing(flash once every second) Battery charging
OFF Battery discharge
2 Dischg Orange ON Battery discharging
OFF Battery charging
4 CHG/ Dischg Green/Orange Both ON Power supply

KEY FEATURES AND FUNCTIONS

Multiple inputs
LMP master power unit may have multiple sources at one time. These sources include the Shore power, Solar panel and Alternator (Motor battery). There is priority among these sources, but LMP allows several sources to charge auxiliary battery at the same time. The priorities are listed below.

Table 2 Energy sources priority 

AC Mains
Solar panel
Alternator (Motor battery)
Dominating Source AC mains+ Solar panel AC mains+ Solar panel AC mains Alternator + Solar panel Solar panel

Battery Charger of Auxiliary Battery
The charger automatically starts when the appropriate qualified power is connected, either from grid, generator. With multiple charging stages (soft start-bulk absorption float-recycle), LMP1218-PWM is designed to fully charge battery quickly. To guarantee the optimal charging for batteries of different states, the LMP1218-PWM features Microprocessor-controlled charging algorithm. The Float and Recycle charging programs guarantees the battery being charged properly upon being connected for a longer period.

IDSWITCH-LMP1218-PWM-Master-Power-Unit - (2)Figure 1 Charging algorithm for lead-acid battery

Lithium battery charging
The LMP1218-PWM can be configured to charge Lithium battery.

Power Supply Mode
If no battery is attached to LMP1218-PWM unit, it will work as a power supply automatically with a 12.8VDC output.

PWM Solar charger controller
LMP has a built-in PWM charger for the service battery.

  • Max open voltage is 30VDC
  • Max supply current is 15A

Voltage Charging Relay (VCR)
LMP1218-PWM Master Power Unit has a built-in voltage charging relay (VCR), which can get power from alternator to supply the system whilst the engine is running.
Here is the working logic of VCR

Table 3 VCR working logic

D+ Enabled D+ Disabled
LFP battery Disengage VCR will be disengaged immediately if no D+ is sensed or detected VCR will be disengaged when alternator/motor battery’s voltage is less than13.5V and charging current is less than 2A for 60S
Engage VCR will be engaged when:1) D+ is sensed or detected; 2) Alternator or motor battery’s voltage is greater than 14.0V for 10S VCR will be engaged when alternator or motor battery’s voltage is greater than14.0V for 10S
AGM/GELbattery Disengage VCR will be disengaged immediately if no D+ is sensed or detected VCR will be disengaged when alternator or motor battery’s voltage is less than12.8V for 60S
Engage VCR will be engaged when:1) D+ is sensed or detected; 2) Alternator or motor battery’s voltage is greater than 12.0V for 10S VCR will be engaged when alternator or motor battery’s voltage is greater than13.4V for 10S

Remarks:
D+ enabled means the LMP box has sensed or detected D+ once, afterwards LMP box would deem it as D+ enabled
D+ disabled means the LMP box has never sensed or detected D+, so LMP box would deem it as D+ disabled

Battery Low Voltage Protection (BLVP)
LMP1218-PWM master power unit has a built-in low voltage protection relay. The protection is decided by battery type lithium battery or lead acid battery. Below please find the protection and resume value:
Table 4 Low voltage protection and resume

 

Protection

 

Threshold value

Low voltage protection GEL/WET/AGM: 10.8+/-0.3Vdc
LFP: 11.2+/-0.3Vdc
Low voltage protection resume  

AGM/GEL/WET: 11.8+/-0.3Vdc

LFP: 12.2+/-0.3Vdc

Remarks:

  • There will be 60 seconds as time delay before above protection or resume

DC DistributionIDSWITCH-LMP1218-PWM-Master-Power-Unit - (3)

STRUCTURE AND INSTALLATION

LMP1218-PWM Master Power Unit IDSWITCH-LMP1218-PWM-Master-Power-Unit - (4)

No. DEFINITION LABEL DESCRIPTION
1 AC input port / AC input port
2 / PV Connect to PV Panel
3 / Fridge Connect to fridge
4 / Lifting Bed Connect to lifting bed
5 / Motor BAT Connect to Motor BAT
6 / AUX BAT Connect to AUX BAT
7 Loads [1]1 POS : Awning lamp
[1]2 GND :
[1]3 POS : Info D+ Fridge
[1]4 POS : Side lights
[1]5 GND : Side lights
[1]6 POS : Info D+ SAT antenna
[1]7 POS : Pump + WC
[1]8 GND : Pump + WC
[1]9 POS : Info D+ Preheating pump
[1]10 POS :    Autoradio Signal
[1]11 GND :
[1]12 GND :
[1]13 POS : Oven + Piezzo
[1]14 GND : Oven +Piezzo

[1]15 GND : Buzzer Footstep
8 Loads [2]1 POS : Lighting Right side
[2]2 GND : Lighting Right side
[2]3 POS : Buzzer Footstep
[2]4 POS : Lighting Left side
[2]5 POS : Lighting Left side
[2]6 GND: In/Out Footstep (COM)
[2]7 POS : Power Tablet
[2]8 GND : Power Tablet
[2]9 Out Footstep (Normally Open)
[2]10 POS:
[2]11 GND:
[2]12 In Footstep (Normally Open)
[2]13 POS + Plug 12V Kitchen
[2]14 GND – Plug 12V Kitchen
[2]15 M1 – Footstep
[2]16 POS + Plug USB Kitchen/Bedroom
[2]17 GND – Plug USB Kitchen/Bedroom
[2]18 M2 -Footstep
9 Loads [3]1 POS : Permanent Autoradio
[3]2 GND :
[3]3 POS : SAT antenna
[3]4 POS : Combi +    TRUMA/ALDE control
[3]5 GND : Combi + TRUMA/ALDE control
[3]6 GND : Elec Fridge
[3]7 POS : TV
[3]8 GND : TV
[3]9 POS : Elec Fridge
10 Signal terminal [7]1 D+ (active high +BAT)
[7]2 Switch ON/OFF (COM)
[7]3 D+ (active down GND)
[7]4
[7]5 Sidelights (active high +BAT)
[7]6 +APC (active high +BAT)
[7]7 Sidelights (active down GND)
[7]8 +APC (active down GND)
[7]9 Switch ON/OFF (NO)
[7]10 Footboard End of stroke (COM)
[7]11 Footboard End of stroke (NO)
[7]12
11 Grey water tank [6]1 CW-REF
[6]2 CW-25%
[6]3 CW-50%
[6]4
[6]5 CW-75%
[6]6 CW-100%
[6]7
[6]8
12 Fresh water tank [5]1 CW-REF
[5]2 CW-25%
[5]3 CW-50%
[5]4 CW-75%
[5]5 CW-100%
[5]6
13 RS485 port Connect to RS485 bus(Optional)
14 CI Bus port Connect to CI bus(Optional)
15 Communication port [4]1
[4]2 GND
[4]3 GND
[4]4 +12V
[4]5 CAN H
[4]6 CAN L
16 DIP Switch 1 VCR Set the battery type, VCR and Mode
2 Mode
3 Bat type
4 Bat type

Installation
For good ventilation, ensure empty space of at least 5 cm on each side of the LMP1218-PWM unit.
IDSWITCH-LMP1218-PWM-Master-Power-Unit - (5) IDSWITCH-LMP1218-PWM-Master-Power-Unit - (6)

Fuse specification
Here is a list for the fuses installed on LMP1218-PWM. Please also take reference of Figure 2.
Table 6 Fuse specification list

Fuse No. DC loads Specification
F2 Awning light 5A
F3 Pump 7.5A
F4 Auxiliarie 10A
F5 Oven 10A
F6 Lighting 1 10A
F7 Lighting 2 10A
F9 USB Socket Bedroom 10A
F10 USB Socket Kitchen 10A
F11 12V Socket Kitchen 15A
F12 Permanent SAT Antenna 10A
F13 Permanent Autoradio 5A
F14 Permanent Heating System 10A
F15 Permanent TV-Demodulator 10A
F16 Lifting Bed 25A
F18 Permanent Fridge 20A
F19 Footboard 20A
F20 AUX BAT 50A
F21 Motor BAT 50A
F1 By-pass Pump 25A
F8 By-pass Lighting 25A
F17 By-pass Lifting 25A

OPERATION

Configuration on LMP1218-PWM
You need to set the battery type, VCR and Mode through LMP1218-PWM master power unit. 5.1.1 Dip switch setting
There are dip switches for you to set VCR mode, Working mode and Battery type.

IDSWITCH-LMP1218-PWM-Master-Power-Unit - (7)

DIP SWITCH 1 2 3 4
VCR mode Working mode Battery type

Dip switch for VCR mode and Working mode
Table 8 Dip switch for VCR mode and Working mode selection

VCR mode off Built-in VCR (Default setting)
on Ex-DC/DC
Working mode off Charger (Default setting)
on Power supply

VCR mode
There are two VCR modes for optional:

  • Integrated VCR: when this mode is selected, the integrated VCR is activated, i.e. 18A
  • Ex-DC / DC: When this mode is selected, the integrated VCR is deactivated; and an IDM NEMO type external DC-DC booster can be connected to replace this integrated VCR
  • Caution If Booster set the VCR to ON and only for LEP lithium batteries

Working mode
There are two working modes for optional:
Charger: When this mode is selected, the LMP will operate as a charger to charge the auxiliary battery as long as the grid or qualified PV is introduced
Power supply: when this mode is selected, the LMP will produce a stable voltage of 12.8 Vdc to power the connected DC loads

Dip switch for battery setting
Table 9 Dip switch for battery type setting

Battery type
off off AGM
off on GEL
on off LFP
on on WET

External Main Switch (Optional)
LMP1218-PWM offers a possibility to connect with an external main switch, which allows user to turn on/off the auxiliary battery output remotely.

IDSWITCH-LMP1218-PWM-Master-Power-Unit - (1)

Daily Maintenance

  • Check and insure the nominal battery voltage is 12Vdc.
  • When replacing the existing battery with a new one, please have the new battery fully charged by Grid for the first time.

Troubleshooting

LED display on LMP
Table 10 Error LED indicator of LMP

NO. LED Color Status Description
1  

 

CHG        / DISCHG

 

Green

/ Orange

Flash once per cycle Service battery voltage low
2 Flash twice per cycle Service battery voltage high
3 Flash 3 times per cycle LMP unit Over temp
4 Flash 4 times per cycle Bulk charge timeout

Specification

Model LMP1218-PWM
Electrical Specifications
Grid Nominal input voltage (V) 230±10%VAC 50/60Hz
Power factor 0.98
Input current at full load 1.3A
Battery Starter battery 12Vdc
Starter battery voltage range 12.8-14.8Vdc
Service battery 12Vdc
Service battery voltage range 10.8-16.2Vdc
PV Charger type PWM
Open circuit voltage 30Vdc
Max supply current 15A
VCR Relay specification 12Vdc 30A continuous, peak current 50A
Connect voltage 13.4V
Connect delay time 10sec
Disconnect voltage 12.8V
Disconnect delay time 60sec
High voltage limit 14.8Vdc
Charger mode Charge Algorithms TBB premium II – 5steps
Battery type AGM/GEL/LFP/WET
Bulk current 18A(Max)
Absorption voltage (14.4/14.1/14.4/14.7)±0.2Vdc
Float voltage (13.5/13.5/13.5/13.7)±0.2Vdc
Power    supply mode Nominal output voltage 12.8±0.2Vdc
Rated output current 18A(Continuous)
Efficiency(Max) 88%
Working temperature -20℃~+40℃
Others
Battery Disconnect (LVD) Disconnect voltage AGM/GEL/WET 10.8±0.3 Vdc
LFP 11.2±0.3 Vdc
Delay off time 60s
 

Reconnect voltage

AGM/GEL/WET 11.8±0.3 Vdc
LFP 12.2±0.3 Vdc
Protection Short circuit on output Fuse blown
Reverse Polarity Fuse blown
Overload protection Derate the output until overload is removed
Battery charger over temperature Shut down LMP
Battery over voltage limits Battery       charger       disconnect,       loads disconnect
Physical Specifications
Dimensions (L*W*H) 235 × 185 × 98.5 mm
Weight (kg) 2kg
Enclosure Plastic case
Cooling By nature
Protection category IP20
Certification
E-mark ECE R10

IDM Technologie
Web: www.idmtech.fr

FAQ

Q: Can I open and service the unit myself?
A: No, only qualified and authorized maintenance personnel should open and repair the unit due to the presence of dangerous voltages and high temperatures.

Documents / Resources

IDSWITCH LMP1218-PWM Master Power Unit [pdf] User Manual
STM250 series, LMP1218-PWM, LMP1218-PWM Master Power Unit, LMP1218-PWM, Master Power Unit, Power Unit

References