HCFa - logoInstallation and Wiring for SV-X3 Series Servo Motor
Hardware InstructionHCFa SV X3 Series Servo Motor

SV-X3 Series Servo Motor

M anual Number MQ075B065A01EN
M anual Version 1.3
Date M ay, 2019

Thank you for purchasing this product.
This manual mainly describes the safety use, installation and wiring for SV-X3 series servo motor.
Form ore details, please refer to < SV-X3 Series Servo Drive Instruction M anual> .
Confirm the following item s when unpacking:

Number Name Quantity
1 Servo motor 1
2 Accessories Flat key 1
4pin term inal 1
2pin term inal (For m otor with brake) 1
3 Installation and Wiring for SV-X3 Series Servo Motor Hardware Instruction 1
4 Certificate of Approval 1

◎ Check if there are som e dam age to the products during transportation.
◎ Any questions, please contact the HCFA Corporation.

Safety precautions

Please pay attention to the flowing safety precautions anywhere and any time during acceptance inspection, installation, wiring, operation and m aintenance.
■ In this m anual, the safety precautions are ranked as ” DAN GER” and ” CAUTION ”
SKIL QC5359B 02 20V Dual Port Charger - danger Indicates that incorrect handling may result in death or severe injury.
SKIL QC5359B 02 20V Dual Port Charger - caution Indicates that incorrect handling m ay result in m edium or slight personal injury or physical dam age.
HCFa SV X3 Series Servo Motor - icon Indicates “ Prohibitions” (Indicates what m ust not be done.)
HCFa SV X3 Series Servo Motor - icon1 Indicates “ Forced” .(Indicates what m ust be done.)

DANGER

Installing and wiring
HCFa SV X3 Series Servo Motor - icon Do not connect the motor to the commercial power. To prevent fire or malfunction.
Do not place the combustibles around the servo motor and drive. To prevent fire.
 

HCFa SV X3 Series Servo Motor - icon1

 

Be sure to protect the drives through the case, and leave specified clearances between the case or other equipment and the drive. To prevent electric shock, fire or malfunction.
Install it at the place free from excessive dust and dirt, water and oil mist To prevent electric shock, fire , malfunction or damage
Install the equipment to incombustibles, such as metal. To prevent fire.
Any person who is involved in wiring and inspection should be fully competent to do the work. To prevent electric shock.
FG terminal of motor and drive must be grounded. To prevent electric shock.
Perform the wiring correctly after cut off the breaker. To prevent electric shock, injury, malfunction or damage
Have the insulation processing when connecting cables. To prevent electric shock, fire or malfunction.
Operation and running
HCFa SV X3 Series Servo Motor - icon During operation, never touch the internal parts of the drive. To prevent burns or electric shock.
The cables should not be damaged, stressed loaded, or pinched. To prevent electric shock, malfunction or damage.
During operation, never touch the rotating parts of the servo motor. To prevent injury.
Do not install the equipment under the conditions with water, corrosive and flammable gas. To prevent fire.
HCFa SV X3 Series Servo Motor - icon

 

Do not use it at the location with great vibration and shock. To prevent electric shock, injury or fire.
Do not use the servo motor with its cable soaked in oil or water. To prevent electric shock, malfunction  or damage
Operate the switches and wiring with dry hand. To prevent electric shock, injury or fire.
Do not touch the keyway directly when using the motor with shaft-end keyway. To prevent injury.
Do not touch the motor and drive heat sink, as they are very hot. To prevent burns or parts damaged.
Do not drive the motor by external drive. To prevent fire.
Other safety instructions
HCFa SV X3 Series Servo Motor - icon1 Confirm  the equipment’s safety after the earthquake  happens. To prevent electric shock, injury or fire.
Installing and setting correctly to prevent the  fire and personal injury when earthquake happens. To prevent injury, electric shock, fire, malfunction or damage.
Provide an external emergency stop circuit to ensure that operation can be stopped and power switched off immediately. To prevent injury, electric shock, fire, malfunction or damage.
HCFa SV X3 Series Servo Motor - icon1 Before wiring or inspection, turn off the power and wait for 5 minutes or more. To prevent electric shock.

CAUTION

Installing and wiring

HCFa SV X3 Series Servo Motor - icon1 Please follow the specified combination of the motor and drive. To prevent fire or malfunction.
Do not touch the terminals of connector directly. To prevent electric shock or malfunction.
HCFa SV X3 Series Servo Motor - icon1 Do not block intake and prevent the foreign matters from entering into the motor  and drive. To prevent electric shock or fire.
Fix the motor and have the test run away from the mechanical system. After confirming the operation,the motor can be securely mounted to mechanical system. To prevent injury.
The servo motor must be installed in the specified direction. To prevent injury or malfunction.
Install the equipment correctly in accordance with its weight and rated output. To prevent injury or malfunction.

Operation and running

HCFa SV X3 Series Servo Motor - icon

 

Do not climb or stand on servo equipment. Do not put heavy objects on equipment. To prevent electric shock, injury, fault or damage.
The parameter settings must not be changed excessively. Operation will be instable. To prevent injury.
When power is restored after an instantaneous power failure, keep away from the machine because the machine may be restarted suddenly(design the machine so that it is secured against hazard if restarted). To prevent injury.
Keep it away from the direct sunlight. To prevent malfunction.
Do not put strong impact on the motor, drive and motor shaft. To prevent malfunction.
The electromagnetic brake on the servo motor is designed to hold the servo motor shaft and should not be used for ordinary braking. To prevent injury or malfunction.
HCFa SV X3 Series Servo Motor - icon1 Do not install or operate a faulty servo motor or drive. To prevent injury, electric shock or fire
Check the power specification. To prevent fault.
The electromagnetic brake may not hold the servo motor shaft. To ensure safety, install a stopper on the machine side. To prevent injury.
A sudden restart is made if an alarm is reset with the run signal on. To prevent injury.
Connect the relay for emergency stop and for brake in series. To prevent injury or malfunction.

Transportation and storage

HCFa SV X3 Series Servo Motor - icon Do not subject the equipment to the place with rain, waterdrop, poisonous gases or liquids. To prevent malfunction.
Do not carry the servo motor by the cables, shaft or encoder during transportation. To prevent injury or malfunction.
Do not drop or dump the motor during transportation and installation. To prevent injury or malfunction.
HCFa SV X3 Series Servo Motor - icon1 Store the unit in a place in accordance with the instruction manual. To prevent malfunction.
If store it for a long time, Consult HCFA. To prevent malfunction.

Other safety instructions

HCFa SV X3 Series Servo Motor - icon1 Please dispose the battery according to your local laws and regulations.
When disposing of the product, handle it as industrial waste.

Maintenance and inspection

HCFa SV X3 Series Servo Motor - icon Do not disassemble and/or repair the equipment on customer side. To prevent malfunction.
Do not turn on or switch off the main power frequently. To prevent malfunction.
Do not touch the servo drive heat sink, regenerative resistor, servo motor etc. Their temperatures may be high while power is on or for some time after power-off. To prevent burns or electric shock.
HCFa SV X3 Series Servo Motor - icon1 When the drive become faulty, switch off the control circuit and main power. To prevent fire.
If the servo motor is to be stored for a long time, switch off the power. To prevent misoperation and injury.

About maintenance and inspection

<  Warranty period>
● The term of warranty for the product is 18 months from the date of manufacture. It’s exceptional to brake motors as they are warranted when acceleration/deceleration times is not beyond the specified service life.
<  Warranty coverage >
● This warranty applies only when  the condition, method, environment, etc. of use  are in compliance with the terms and conditions and instructions that are stated in the instruction manual and user manual for the Product.
However, even during warranty period, the repair cost will  be charged  on  customer in the following cases.
1) A failure caused by improper storing or handling, repair and modification.
2) A failure caused by the parts which have dropped down or damaged during transportation
3) A failure caused when the products have been used beyond the product specification
4) A failure caused by external factors such as inevitable accidents, including but not limited to fire, earthquake, lightning stroke, windstorm disaster, flood, salt damage, abnormal fluctuation of voltage and other natural disaster.
5) A failure caused by the intrusion of water, oil, metal and other foreign matters.
● The warranty coverage is only for the product itself. We assume no responsibilities for any losses of opportunity and/or profit incurred by you due to a failure of the Product.

Product introduction and model selection

Introduction for motor nameplate
Servo motor nameplateHCFa SV X3 Series Servo Motor - fig

Model name identification

HCFa SV X3 Series Servo Motor - fig1

Motor parts name

HCFa SV X3 Series Servo Motor - fig2

Model name of servo drive and motor

Capacity Motor model SV-X3□□□□□-*2** Motor size (Flange installation size) Drive model Drive size
50W Middle inertia MM 005A 40 SV-X3DA005A-D  

 

Frame A

100W Middle inertia MM 010A SV-X3DA010A-D
200W Low inertia MA020A  

60

SV-X3DA020A-D
High inertia MH020A
400W Low inertia MA040A SV-X3DA040A-D
High inertia MH040A
750W Low inertia MA075A 80 SV-X3DA075A-D
High inertia MH075A
1kW Middle inertia MM 100A  

130

SV-X3DA100A-A Frame B
High inertia MH100A
1.5kW Middle inertia MM 150A SV-X3DA150A-A
High inertia MH150A
2kW Middle inertia MM 200A SV-X3DA200A-A

Motor specification

SpecificationHCFa SV X3 Series Servo Motor - Table 1 HCFa SV X3 Series Servo Motor - Table 2Ambient conditions and safety precautions

 

Ambient conditions

Rated time Continuous
Ambient temperature for use 0~40(Without condensation)
Ambient humidity for use 20~85(Without condensation)
Ambient temperature for storage -20~65 (Without condensation), Highest temperature guaranteed: 80 degrees, 72hours
Ambient humidity for storage 20~85(Without condensation)
Atmosphere for use/storage Indoors(Not subject to rainwater or direct sunlight); free from corrosive gas, flammable gas, flammables, grinding fluid, oil mist, or dust
Insulation class Class B
Insulation resistance 1000 VDC megger  5MΩ or more
Dielectric strength 1500VAC for 1 minute
Altitude 1000m or less above sea level
Vibration class V15 (JEC2121)
Vibration resistance 49m/s2(5G)
Impact resistance 98m/s2(10G)
Protective class IP65(Excluding shaft penetrating section and connectors)
 

Points to note

・Grounding is mandatory. Class Ⅰ
・“Over voltage category Ⅱ  ”
・“  Pollution degree2”
・Brake cable has polarity. Red: connecting with +24V; Black: connecting with GND.

Output shaft permissible load

HCFa SV X3 Series Servo Motor - fig 3

Permissible load Unit 50W 100W 200W 400W 750W 1kW 1.5kW 2kW
Radial load N 68 68 245 245 392 490 490 490
Axial load N 58 58 98 98 147 196 196 196

HCFa - logo

Documents / Resources

HCFa SV-X3 Series Servo Motor [pdf] Installation Guide
SV-X3 Series Servo Motor, SV-X3 Series, Servo Motor, Motor

References

Leave a comment