Specifications:

  • Input Current: Less than 200 mA
  • Output: 4 NO (SPST)
  • Max Switching Current: 10 A, 250 V AC1 / 4 A, 24 V DC1
  • Power Consumption: 0.5 Nm
  • Motor Power: 1/2 HP 240 V AC / 1/4 HP 120 V AC
  • Digital/Analog Inputs: 8 (0-10 V)
  • Processor: STM32H747XI Dual ARM Cortex M7/M4 IC
  • Communication Interfaces: USB Type C, 10/100 Ethernet, RS485,
    Wi-Fi + BLE
  • Mounting: EN 60715 rail mounting
  • Environmental Conditions: Extended Humidity 5-95 RH%, Altitude
    2000 m, IP20

Product Usage Instructions:

Installation:

  1. Ensure the device is mounted on an EN 60715 rail securely.
  2. Connect the appropriate power source based on the motor power
    requirements.
  3. Connect any required digital/analog inputs to the designated
    ports.
  4. Establish communication interfaces such as USB Type C,
    Ethernet, RS485, Wi-Fi, or BLE as needed.

Operation:

  1. Power on the device using the specified power source.
  2. Monitor the device status using the LED indicators.
  3. Utilize the digital/analog inputs for controlling the device
    based on the application requirements.
  4. Ensure proper communication via the available interfaces for
    data exchange.

Maintenance:

  1. Regularly check for any loose connections or signs of wear and
    tear.
  2. Clean the device and its surroundings to prevent dust
    accumulation.
  3. Update firmware or software as recommended by the manufacturer
    for optimal performance.

FAQ:

Q: What should I do if the device shows an error code?

A: Refer to the user manual for error code explanations and
troubleshooting steps. If the issue persists, contact customer
support.

Q: Can I use this product in all EU member states?

A: Yes, this product is compliant with EU regulations and can be
used in all EU member states.

Q: How do I reset the device to factory settings?

A: Locate the RESET button on the device and follow the
instructions in the manual to perform a factory reset.

“`

8A.04.9.024.832C
UN (12…24) V DC + ­15% Class 2 source
I < 200 mA

1
0.5 Nm

OUTPUT

4 NO (SPST)

10 A, 250 V AC1

4 A, 24 V DC1

1M~

1/2 HP 240 V AC 1/4 HP 120 V AC

8 digital/ analog (0…10 V) INPUT

9mm
1×2.5 / 2×1.5 mm2 1×14 / 2×16 AWG

STM32H747XI Dual ARM R Cortex R M7/ M4 IC:

9mm

1x ARM R Cortex R -M7 core up to 480 MHz

1x ARM R Cortex R -M4 core up to 240 MHz

2

1×2.5 / 2×1 mm2

USB Type C

1×14 / 2×16 AWG

10/100 Ethernet

RS485

8A.04

Wi-Fi + BLE

Secure element integrated

2a

(­20…+50)°C
Open type, EN 60715 rail mounting Environmental Conditions: Extended
Humidity 5-95 RH% Altitude 2000 m IP20

LISTED
E528578

FCC ID: 2A97G-8A001 (Only for mod: 8A…832C)

Utility Model – IB8A04832CVXX – 01/25 – Finder S.p.A. con unico socio – 10040 ALMESE (TO) – ITALY

FCC and RED CAUTIONS (MODEL 8A.04.9.024.832C)

FCC

Any Changes or modifications not expressly approved by the party responsible

3a

for compliance could void the user’s authority to operate the equipment.

This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions: (1) This device may not

cause harmful interference, and (2) this device must accept any interference

received, including interference that may cause undesired operation.

FCC RF Radiation Exposure Statement:

3c

– this Transmitter must not be co-located or operating in conjunction with any

other antenna or transmitter

3d

– this equipment complies with RF radiation exposure limits set forth for an

uncontrolled environment

– this equipment should be installed and operated with minimum distance

20 cm between the radiator& your body 3e

NOTE

This equipment has been tested and found to comply with the limits for a Class A

digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful

3f

interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and,

if not installed and used in accordance with the instruction manual, may cause

harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful

interference in which case the user will be required to correct the interference

at his own expense.

RED

The product is in compliance with essential requirements and other relevant

provisions of Directive 2014/53/EU.

3k

This product is allowed to be used in all EU member states.

Frequency bands

Maximum output power (EIRP)

2412 – 2472 MHz (2.4G WiFi) 2402 – 2480 MHz (BLE) 2402 – 2480 MHz (EDR)

5,42 dBm 2,41 dBm ­6,27 dBm

3
3b 3j 3i
3h 3g
3m

8A.04.9.024.8320C Codesys
1
2
2a Modbus RTU 3n
3
3a 12…24 V DC 3b I1….I8 / (0…10 V)
IDE 3c RESET ( ) 3d 3e LED 1…4 3f 1…4, (SPST) 10 A 250 V AC 3g 3h LED Ethernet (ETH) 3i 060.48 3j MODBUS RS485 3k USB Type-C 3m Ethernet 3n
opta.findernet.com Finder OPTA Type 8A.04 , CODESYS Finder, opta.findernet.com. Finder OPTA Type 8A.04 , USB-C. Finder OPTA Type 8A.04, LED.
, .

Documents / Resources

finder IB8A04832CVXX CODESYS Light Plus Building Contactor [pdf] Instructions
IB8A04832CVXX, IB8A04832CVXX CODESYS Light Plus Building Contactor, CODESYS Light Plus Building Contactor, Light Plus Building Contactor, Building Contactor

References

Leave a comment

Your email address will not be published. Required fields are marked *