FASTUS CDA-DM2 Displacement Sensor Amplifier Unit Instruction Manual

CDA-DM2 Displacement Sensor Amplifier Unit

Product Information

Specifications:

  • Model: CDA-DM2
  • Manufacturer: OPTEX FA CO.,LTD.
  • Warranty Period: 1 year after delivery

Product Usage Instructions

Safety Precautions:

  • WARNING: Do not disassemble, repair, modify,
    deform under pressure, or attempt to incinerate the product.
  • WARNING: Do not use the product around
    flammable or explosive gases or liquids.
  • CAUTION: Turn off the power before wiring the
    cable or connecting/disconnecting the connector.
  • CAUTION: Avoid using the transient state while
    the power is on.
  • CAUTION: Do not wire with high voltage cables
    or power lines.
  • CAUTION: Do not bend the cable below freezing
    point.
  • CAUTION: Do not drop the product or subject it
    to strong impacts.

Handling Precautions:

After considering the intended use, required specifications, and
usage conditions, install and use the product within the specified
ranges. All specifications are subject to change without notice.
Ensure necessary safety designs when using the product.

Included Accessories:

Confirm that the following accessories are included in the
box.

Dimensions:

Unit (mm) – 23 x 34 x 78

M8 Connector – Pin No. (1) (2) (3) (4)

I/O Circuit Diagram:

The input/output circuits of this unit are as follows. Use the
settings to switch between NPN and PNP outputs.

Frequently Asked Questions (FAQ):

Q: What should I do if the product is exposed to flammable
gases?

A: Do not use the product around flammable or
explosive gases or liquids to avoid ignition resulting in an
explosion or fire.

Q: Can I repair the product myself if it malfunctions?

A: Avoid disassembling, repairing, or modifying
the product yourself. Contact authorized service centers for
repair.

“`

0808880
INSTRUCTION MANUAL
Displacement sensor amplifier unit
CDA-DM2
OPTEX FA CO.,LTD.
Thank you for purchasing the CDA-DM2 displacement sensor amplifier unit. Before using this product, please read this manual carefully to ensure proper use. Read this manual thoroughly, and then keep this manual at hand so that it can be used whenever necessary. The warranty period of this product is one year after delivery. However, any fault attributable to natural disas-
ters or any other similar disasters or modification or repair will be excluded from the scope of the warranty.
Safety Precautions
Safety precautions for ensuring safe operation of this product are displayed as follows with the following symbols. Precautions listed here describe important information about safety. Make sure to follow them accordingly.
Safety Symbols
WARNING Indicates that any improper operation or handling may result in moderate or minor injury, and in rare cases, serious injury or death. Also indicates a risk of serious property damage.
CAUTION Indicates that any improper operation or handling may result in minor injury or property damage.
WARNING
Do not disassemble, repair, modify, deform under pressure, or attempt to incinerate this product. Doing so may cause injury or fire.
This product is not explosion-proof and should not be used around flammable or explosive gases or liquids. Doing so may cause ignition resulting in an explosion or fire.
Do not use air dusters or any spray that uses flammable gas around the product or on the inside of the product. Doing so may cause ignition resulting in an explosion or fire. Do not install this product in any of the following locations. Doing so may cause a fire, damage, or a malfunction.
1. Locations where dust, salt, iron powders, or vapor (steam) is present. 2. Locations subjected to corrosive gases or flammable gases. 3. Locations where oil or chemical splashes may occur. 4. Locations where heavy vibrations or impacts may occur. 5. Locations where the ambient temperature exceeds the rated range. 6. Locations subject to rapid temperature changes (or where condensation occurs). 7. Locations with strong electric or magnetic fields. 8. Outdoor locations or locations subject to direct light. Do not use this product in a non-industrial setting. Doing so may cause induction or radiation interference. This product is not intended for use with nuclear power, railways, aviation, vehicles, medical equipment, food-handling equipment, or any application where particular safety measures are required. Absolutely do not use this product for any of these fields. This product cannot be used in applications that directly or indirectly detect human bodies for the purpose of ensuring safety. Do not use this product as a detection device for protecting the human body. What to do in the event of a malfunction such as smoke being emitted from the product If you detect any malfunction including emission of smoke, abnormal smells or sounds, or the body becoming very hot, immediately stop operating the product and turn off the sensor power. Failure to do so may cause a fire. Repairing the product is dangerous and should in no way be performed by the customer. Contact an OPTEX FA sales representative for repairs.
CAUTION
Make sure to turn the power off before wiring the cable or connecting/disconnecting the connector. Connecting or disconnecting while energized may damage the product or cause electric shock.
Avoid using the transient state while the power is on (100 ms). Output could become unstable, causing unexpected operation.
Do not wire with high voltage cables or power lines. Doing so may cause malfunction or damage by induction. Do not bend the cable when below the freezing point. This may cause the cable to break. Do not drop the product or subject the product to strong impacts. Doing so may damage the product. Follow the instructions in this manual or the specified instruction manual when wiring the product
or the dedicated controller for the correct wiring method. Incorrect wiring can damage the product or the controller, or cause a malfunction. When disconnecting the connector, be careful not to touch the terminals inside the connector, and do not allow foreign objects to enter the connector. Install this product as far away as possible from high-voltage equipment, power equipment, equipment that generates large switching surges, inverter motors, welders, or any equipment that can be a source of noise. When connecting or disconnecting the cable, make sure to hold it by the connector portion, and do not apply excessive force to the cable.
Handling Precautions
After carefully considering the intended use, required specifications, and usage conditions, install and use the product within the specified ranges.
All specifications may be changed without notice. When using this product, it is the responsibility of the customer to ensure necessary safety designs
in hardware, software, and systems in order to prevent any threat to life, physical health, and property due to product malfunction or failure. Do not use this product for the development of weapons of mass destruction, for military use, or for any other military application. Moreover, if this product is to be exported, comply with all applicable export laws and regulations, including the “Foreign Exchange and Foreign Trade Act” and the “Export Administration Regulations,” and carry out the necessary procedures pursuant to the provisions therein. For more details on conformity to the Restriction of Hazardous Substances Directive for this product, please contact an OPTEX FA sales representative. Before using this product, fully examine the applicable environmental laws and regulations, and operate the product in conformity to such laws and regulations. OPTEX FA does not assume any responsibility for damages or losses occurring as a result of noncompliance with applicable laws and regulations. Detection characteristics and digital display values may vary depending on the state of the target object and variations among individual products.

1. Included Accessories
Confirm that the following accessories are included in the box.

· CDA-DM2

· This instruction manual

2. Dimensions
Unit (mm)

23

34

78

33.2 10

8.4

9.6

9.6

18.8

36.6

ø5.8, 7-wire 2 m cable

[M8 connector]

(4)

(2)

(3)

(1)

Pin No. (1) (2) (3) (4)

Function 12 to 24 VDC ±10% RS-485 (B) 0 V RS-485 (A)

3. I/O Circuit Diagram

The input/output circuits of this unit are as follows. Use the settings to switch between NPN and PNP outputs.
With the NPN output setting
(+) V (brown) Power supply

Internal circuit

3.3 V

Control output 1 (black), 2 (yellow)
External input (purple) Analog output (+) 1 (white),
2 (pink)
Analog output (-) 1 (shielded), 2 (shielded)
0 V (blue)

Internal circuit

With the PNP output setting
(+) V (brown) Power supply
Control output 1 (black), 2 (yellow)
External input (purple)
Analog output (+) 1 (white), 2 (pink)
Analog output (-) 1 (shielded), 2 (shielded)
0 V (blue)
* Use shielded cables for analog output (+) and analog output (-), and wire as a pair up to the analog input device.

4. Part Names

Display panel Head connector

Operating panel
Power indicator Output 1 indicator
PWR OUT1 OUT2 OUT3
Output 2 indicator Output 3 indicator

Main unit cable

Display panel B button

BA

A button

Arrow buttons

Indicators

Name

Color

Indication

Power supply

Green/Red Green: Power on Red: Head communication error Flashing: In power-saving mode

Output 1 indicator Orange Lit: Output 1 ON Not lit: Output 1 OFF

Output 2 indicator Orange Lit: Output 2 ON Not lit: Output 2 OFF

Output 3 indicator Orange Lit: Output 3 ON Not lit: Output 3 OFF

5. Basic Operations

Button types and operations

Button shape

Name

A button

B button

On-screen display

Function

Quick press (less than 2 sec.): “Set”

Long press (2 sec. or more): “Finish”

“Cancel”

Up/down buttons

Select item; Increase/decrease value

Left/right buttons

Select menu

Screen image

AMP APP Settings Upper Limit
100

°~Change Value Set

° ~

Select Digit

Back

Finish

* The language selection screen is displayed when the power is turned on for the first time. Use / to select the desired language, and press (A button) to confirm the selection.
* The language can be changed at any time from the “Expert Mode” menu.

6. Functions
Power-save display
If no button operation is detected for 10 minutes, the settings and measurement displays will turn off. During this period, the PWR LED (power indicator) will flash every second. Pressing any button will return the display to normal. Return operation is also possible when the keys are locked.

External input
Functions such as offset execution can be assigned to external inputs. Assigned functions will work simultaneously on the Ch 1 and Ch 2 heads.
High-accuracy analog output
The CDA-DM2 is equipped with two 16-bit resolution analog output circuits. The voltage and current for each analog output can be independently switched as desired, and output values can be specified as measurement values or calculation results for each channel as desired. For details, see the CDA series user’s manual.
Key lock/unlock
Press and hold (B button) for at least 2 seconds on the measurement screen or calculation results display screen to lock the keys. While the keys are locked, “Key Locked” is displayed at the bottom of the measurement screen. Press and hold (B button) again for at least 2 seconds to unlock the keys.

7. Connectable Devices
Compatible sensor heads
TD1 series through-beam edge sensor CD22 series compact laser displacement sensor (RS-485 communication type) CDX series ultra high-accuracy laser displacement sensor * For connection details, see the instruction manual for the specific sensor head.
Communication units
UC1 series communication unit CDA-S displacement sensor amplifier unit (slave unit) * For connection details, see the instruction manual for the specific unit.

8. Specifications

Model

CDA-DM2 (Master unit)

Mounting method

DIN rail mounting

Sensor head Max. number of connections

2 units

Connector

M8, 4-pin

Protocol

RS485-compliant (max. length of extension cable: 10 m)

Display

Measurement value/ 128 × 96 dot matrix display; Japanese/English (selectable) setting

Indicators

Power: Green, Output: Orange

I/O

External input

1 input (enabled for Ch 1 and Ch 2)

Control output

2 outputs, PNP/NPN selectable; Open collector; 24 VDC / 100 mA or less; Residual voltage: 1.8 V or less

Analog output

2 outputs, voltage/current selectable Current: 4 to 20 mA (Max. load: 300 ) Voltage: 0 to 10 V (Output impedance: 100 )

Ratings

Supply voltage

12 to 24 VDC ±10%

Current consumption 120 mA or less (at 12 V) *1

Environmental Protection circuit

Reverse connection protection,overcurrent protection

resistance

Degree of protection IEC standard, IP50

Ambient temperature/ -20 to +50°C / 35 to 85% RH (no freezing or condensation) humidity

Storage temperature/ -20 to +60°C / 35 to 85% RH (no freezing or condensation) humidity

Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2 (approx. 50 G); 3 times in each of the X, Y, and Z directions

Material

PC

Weight

170 g

*1:Does not include current supplied to any connected sensor head or slave unit.

Support for the China RoHS directive For details on the support for the China RoHS directive, see the following website. https://www.optex-fa.jp/rohs_cn/

www.hemomatik.se
Ordertel 08-771 00 04 Växel 08-771 02 20 Teknisk 08-771 35 80 Länna, S-142 50 SKOGÅS (Stockholm)

Documents / Resources

FASTUS CDA-DM2 Displacement Sensor Amplifier Unit [pdf] Instruction Manual
CDA-DM2, CDA-DM2 Displacement Sensor Amplifier Unit, CDA-DM2, Displacement Sensor Amplifier Unit, Sensor Amplifier Unit, Amplifier Unit, Unit

References

Leave a comment

Your email address will not be published. Required fields are marked *