EXCELL logoEXCELL PRECISION CO.,LTD.
X Series Weighing Scale

User Manual
02036XXX
ZSME300000422

 

 

© EXCELL PRECISION CO., LTD. All rights reserved worldwide.
The information contained herein is the property of EXCELL PRECISION CO., LTD. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
Check Firmware Version
Turn on scale and hold ZERO key during countdown. Display firmware version 02036.
Turn off scale and turn on scale and hold TARE key during countdown. Display maintenance number XXX, which is ranged from 0~999. Turn off and turn on scale to return to weighing mode.
Thank for your purchasing of our EXCELL Weighing Scale. To guide you to use our product correctly, please read this User Manual carefully to extend the life of machine and to avoid error.

Preparing to Use the Scale

  1. Locate the scale on a firm level surface free from vibrations for accurate weight readings.
    Adjust the four leveling feet to centre the leveling bubble on the scale.
  2. Avoid hot sunshine directly on the scale or near the exhaust port of ventilating system.
  3. Please use a separate power source plug to avoid the disturbance of other electric appliances.
  4. There should be no weight on the scale when power is turned on.
  5. Commodity should be placed at the centre of platter when being weighed, and its size should not exceed the dimension of the platter.
  6. Please warm the scale 15 ~ 20 minutes before using.
  7. Please note that when symbol EXCELL X Series Weighing Scale - icon 1appears on the screen, the scale needs to be charged.
  8. Any suggestion is warmly welcome.

Precautions for Use

  1. Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire.
  2. Please keep scale in a cool and dry place. Do not store under high temperatures.
  3. Please keep the scale clean and free from insect infestation.
  4. Avoid impacting with other items or overloaded with excessively heavy weights (The load must not exceed the maximum capacity of the scale).
  5. If the scale is not going to be used for some time, please clean it and store it in a plastic bag in dry condition. A desiccant sachet may be included to prevent moisture from building up.
  6. Operating temperature: -10℃ ~ + 40℃
  7. It is recommended to be used indoors and in environments with a height of less than 2000m
  8. If the product is used in a manner not specified by the manufacturer, product warranty may be limited.

Safety Instructions for Lithium Batteries

  1. Please pay attention to the storage temperature of the product. Do not place it in a high temperature environment. The ambient temperature should be less than 50C.
  2. After installing the battery, if no display when power is turned on, please check whether the battery polarity is reversed. The polarity must be installed correctly to avoid battery power wasted away.
  3. When the LED flashes in the charging state, it means there are the following abnormal states, please check:
    a) Battery is installed but the contact is poor, please check whether the battery is installed properly.
    b) Please check whether the polarity of the battery is reversed. When the polarity is reversed, the LED will flash after charging for a period of time.
    c) When battery is removed and the AC power cord is still plugged in, the LED will also flash.
    When plugged in without the battery installed, there will be a slight frequency conversion sound, which is normal and does not affect the use of the function.
  4. When EXCELL X Series Weighing Scale - icon 1symbol appears, scale needs to be charged.
    a) When charging, the red LED will light up. Please refer to 1-4 for estimated charging hours.
    b) When the battery is fully charged, blue LED will light up.
    c) If scale is fully charged, after plugging in, the blue light will turn on after about 5~10 minutes of voltage detection. The LED charging indicator is to indicate the status of the charging process and whether the charging is working properly. To check the battery level, please unplug the AC cable first and turn on scale, and then check the battery symbol EXCELL X Series Weighing Scale - icon 2displayed in the lower left corner of the display. The number of bars under the battery symbol indicates battery level. 0 bar means <= 10% when the low power warning symbol (EXCELL X Series Weighing Scale - icon 1 ) flashes to indicate that scale needs to be charged.
  5. Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire. While charging, the temperature of battery should below 45℃.
  6. Our product uses a single-cell cylindrical 18650-3.7V lithium-ion battery. Battery’s should be 3.6~3.7V and capacity is not restricted.EXCELL X Series Weighing Scale - icon 3
  7.  If the appearance of the battery is deformed, damaged, etc., please do not install it for the safety of use.

Chapter 1 Introduction

1-1 Production Introduction

  1. High performance A/D converter
     0.3 uv/D high sensitivity
     zero point adjustable range -2mV~ +5mV
     Sampling speed 10 times/second  use range -4mV ~ +30mV
     non-linear scale 0.01% full scale
     load cell stimulate power source 5V DC ±2% 100mA
  2. According to different resolution to do linearity calibration
     Ordinary resolution models (below 10000)
    Do specification calibration first then do weight calibration
     High resolution models (10000~30000)
    Do linearity calibration first specification calibration  weight calibration at last LCD display with LED backlight, powered by battery or plug-in mains, automatic power-off function to ensure the stability of the scale. When battery voltage is lower than the system voltage, scale is automatically powered off to ensure the accuracy and stability of the scale.
  3. Check Weighing function for high limit and low limit and OK range.
  4. 4 HOLD functions including animal scale HOLD
  5. Depending on actual space, a RS232 card and/or a relay card can be installed.

1-2 Display Description EXCELL X Series Weighing Scale - Display

HI : High limit value
OK : OK range within HI and LO limits
LO : Low limit value
kg : “kg” unit
lb : “lb” unit
Pcs : Counting mode
% : Percent indication
→O← : “Zero” indication
Net : “Net weight”

indication

EXCELL X Series Weighing Scale - icon 1 : “Low battery

power” indication

▼1 “Stable” indication
▼2 : “Pre-tare mode” indication
▼3 : (M+) “Accumulation mode” indication
▼5 : (   EXCELL X Series Weighing Scale - icon 5  ) “Samples insufficient” indication
▼6 : (       EXCELL X Series Weighing Scale - icon 6 ) “Unit weight insufficient” indication
▼7 : “Viss” unit (Burma unit)

EXCELL X Series Weighing Scale - icon 9  For Dual Range Models, the indicator 5 and 6 will be defined as below:
▼6 is Range 1 ▼5 is Range 2
1-3 Keypad Functions Description EXCELL X Series Weighing Scale - Keypad

Key description 4/5 key 10 key 12 key Other variation
Net/Gross key EXCELL X Series Weighing Scale - icon 10 NET/GROSS
Loop select from the preset units

UNITS

UNITS UNITS lb/kg
Preset weight and quantity for weight check or quantity check EXCELL X Series Weighing Scale - icon 19 TGT SET
Accumulate weight or quantity + M+
Tare to deduct the container weight EXCELL X Series Weighing Scale - icon 11 EXCELL X Series Weighing Scale - icon 11 EXCELL X Series Weighing Scale - icon 11 TARE
Set preset tare EXCELL X Series Weighing Scale - icon x 1
Recall the totalization value, preset value and pre-tare value EXCELL X Series Weighing Scale - icon 12 EXCELL X Series Weighing Scale - icon 12 RE-CALL
Clear the totalization value, preset value and pre-tare value. CE CE
Zero the scale. EXCELL X Series Weighing Scale - icon 13 EXCELL X Series Weighing Scale - icon 13 EXCELL X Series Weighing Scale - icon 13 ZERO
Press this key to input the numbers (0 ~ 9) and to light up the backlight. EXCELL X Series Weighing Scale - icon 15 EXCELL X Series Weighing Scale - icon 16
Press this key to print the total data and to confirm EXCELL X Series Weighing Scale - icon 1ccc EXCELL X Series Weighing Scale - fig34x EXCELL X Series Weighing Scale - icon 36 PRINT
Go into counting mode. EXCELL X Series Weighing Scale - icon 17 EXCELL X Series Weighing Scale - icon 17  

COUNT or Q’TY SET

 

Press this key to sample. EXCELL X Series Weighing Scale - icon 18 EXCELL X Series Weighing Scale - icon 18 SMPL

EXCELL X Series Weighing Scale - icon 20 key andEXCELL X Series Weighing Scale - icon 19 key are not available for 10-key models.
1-4 Power Description 

Power Battery 18650 3.7V lithium battery
Plugged in 100~240V AC
Power consumption varies depending 0~100% backlight used (mA) No backlight 75% backlight (factory default)
≈ 24 ≈ 28

Scale has a built-in power saving function to extend usage time. Table below shows the battery capacity and estimated usage time. Time may vary with different brands of lithium batteries and are for reference only.

Battery capacity 2000mA 2500mA 3000mA 3200mA 3500mA
Average usage time 80~90

hours

95~105

hours

110~120

hours

120~130

hours

130~140

hours

Estimated charging time ≈2.5 hours ≈3 hours ≈3.5 hours ≈4 hours ≈4.5 hours
Assume 25% in use for average usage time. If use continuously, time will be reduced by ~40%.

Low Power Alarm
When EXCELL X Series Weighing Scale - icon 1symbol flashes, scale needs to be charged. To check the battery level, please unplug the AC cable first, and check the battery symbol EXCELL X Series Weighing Scale - icon 2 displayed in the lower left corner of the display. The number of bars under the battery symbol indicates battery level. 4 bars mean 100%, 3 bars mean 75%, 2 bars mean 50%, 1 bar means 25%, and 0 bar means <= 10% when the low power warning symbol (EXCELL X Series Weighing Scale - icon 1 ) flashes to indicate that scale needs to be charged. If not charge immediately, scale auto shuts down within 5~10 hours or 1~2 hours with backlight. The cut voltage is about 3.5V. Once it auto shuts down and enters the battery protection mode, it must be charged before it can be used again.
EXCELL X Series Weighing Scale - icon 9Please recharge at once when the symbolEXCELL X Series Weighing Scale - icon 1 shows in order to keep the weight accuracy.
EXCELL X Series Weighing Scale - icon 9 Charging indicator a) When charging, the red LED will light up. Please refer to 1-4 for estimated charging hours.
b) When the battery is fully charged, blue LED will light up.
c) If scale is fully charged, after plugging in, the blue light will turn on after about 5~10 minutes of voltage detection. The LED charging indicator is to indicate the status of the charging process and whether the charging is working properly. To check the battery level, please unplug the AC cable first and turn on scale, and then check the number of bars under battery symbol for battery level.
1-5 Error Messages
oL EXCELL X Series Weighing Scale - icon 21 Weight exceeds 9d of maximum capacity. (d=division)
E1 EXCELL X Series Weighing Scale - icon 21 Zero value after power on is over +10% FS.
E2 EXCELL X Series Weighing Scale - icon 21 Zero value after power on is less than -10% FS.
EXCELL X Series Weighing Scale - icon 9 need to set C5 to 1 to have E1 and E2 warnings
E4 EXCELL X Series Weighing Scale - icon 21 Unstable zero return, unstable over 10 sec. Press
to leave E4.
E6EXCELL X Series Weighing Scale - icon 21 Zero is too high when calibrating. (over internal value 350,000)
E7 EXCELL X Series Weighing Scale - icon 21 Zero is too low when calibrating. (under internal value 80,000)
E8 EXCELL X Series Weighing Scale - icon 21 Resolution is set higher than factory setting. Send it back to us to unlock to set new resolution.
E10 EXCELL X Series Weighing Scale - icon 21 The scale is not in level status.(only available with level detector equipment.)
– – – – – – EXCELL X Series Weighing Scale - icon 21For weight < -20d without tare or pretare device in operation.
EXCELL X Series Weighing Scale - icon 9 OIML approval models need to set C5 to 1 to show “- – – – – -“
E10 Level Switch (option)
Make PCB J3 open circuit and connect signal to CN7 of PCB. Display shows E10 after 2 seconds and all keys stop working in the mean time. If you do not need level switch, make J3 short circuit.

Chapter 2 General Operation Description

2-1 Backlight Function
Press EXCELL X Series Weighing Scale - icon 16key to loop select the display backlight mode: Auto 1~4, bL. on, bL. oFF.
Auto 1~4 EXCELL X Series Weighing Scale - icon 21 “Auto Backlight” mode. When the weight is over 10d or any key is pressed, the backlight will be switched on. When the weight returns to zero (the weight on platform is less than 10d), the display backlight will switch off after 10 seconds.
1~4 (25%~100% backlight) is the brightness selection. Default is 3 (75%).
bL. On EXCELL X Series Weighing Scale - icon 21 Display backlight is on all the time.
bL. oFF EXCELL X Series Weighing Scale - icon 21 Display backlight is off.
2-2 Weighing Mode
2-2-1 Units Selection (not available in 4 key model)

  1. After indicator is turned on, use UNITS key to select a unit from kg, lb, tael or viss, as the screen indicated.
  2.  The selected unit will be memorized when you turn the indicator off. And the memorized unit will appear after you turn on the indicator next time.

2-2-2 Zero Function
Press EXCELL X Series Weighing Scale - icon 7key to re-zero the display with no load on the platter. When zero is set, the (EXCELL X Series Weighing Scale - icon 7 ) symbol will be displayed.
2-2-3 Tare Function

  1. When the weight of the container is unknown (EXCELL X Series Weighing Scale - icon 30. )
    1.  Place the container on the platter, after stable and pressEXCELL X Series Weighing Scale - icon 30. key, the weight value returns to zero and net indication (Not ) is on.
    2. Place goods into the container, then the indicator shows the net weight of goods.
    3. Clear tare value
    When removing the container and goods, the display shows the negative weight value of the container. Then press key to clear tare value. The indicator returns to zero and net indication ( Not ) is on.
    4. Recall tare value PressEXCELL X Series Weighing Scale - icon 12 then key EXCELL X Series Weighing Scale - icon 30. the display shows tare value
     Multiple tare operation EXCELL X Series Weighing Scale - icon 21 Users can continuously increase or decrease the tare value by pressing theEXCELL X Series Weighing Scale - icon 30. key.
     The total tare value (tare value + pre-set tare value) can equal the full capacity of the indicator.
  2.  When the weight of the container is known ( EXCELL X Series Weighing Scale - icon 20)
    1.  Press EXCELL X Series Weighing Scale - icon 20key and the display showsEXCELL X Series Weighing Scale - icon 30 Use and keys to input weight value of the container. After finishing the procedures, the net indication (Not ) and pretare indication “” is on.
    2.  Place goods into the container, then the indicator shows the net weight of goods.
    3. Clear pretare value Press EXCELL X Series Weighing Scale - icon 12thenEXCELL X Series Weighing Scale - icon 20 key, and then press CE key to clear pretare value.
    When indicator returns to zero, net indication (Not ) and pretare indication “”▼ are off.
    4.  Recall pretare value PressEXCELL X Series Weighing Scale - icon 12 thenEXCELL X Series Weighing Scale - icon 20 keyEXCELL X Series Weighing Scale - icon 21  the display shows pretare value

EXCELL X Series Weighing Scale - icon 9 In Tare mode, the Preset tare function is disabled.
EXCELL X Series Weighing Scale - icon 9 The indicators with two weighing ranges can NOT pre-set the tare value larger than the first weighing range. For example: a 30 kg indicator is set by two weighing ranges. The first range is 0 to 15 kg, and the second range is 15 to 30 kg. The pre-set tare value can not be larger than 15 kg.
2-2-4 Net/Gross Function (only available in 4/5 key models)
In Tare mode, pressEXCELL X Series Weighing Scale - icon 37 key once to display gross value. Net symbol “▼”disappears, and the gross value “▼” appears. Press EXCELL X Series Weighing Scale - icon 37key again, it displays net value, net symbol “▼” appears and gross symbol “▼” disappears. Press EXCELL X Series Weighing Scale - icon 37key continually to display net value or gross value. In tare mode, key is able to work. When it displays “▼”, all keys are disable exceptEXCELL X Series Weighing Scale - icon 37.
2-2-5 Check Weighing Mode (4/5 key models need to set through F4)

  1. Preset “ High limit”, “Low limit” and “ Beeper value” operation Use EXCELL X Series Weighing Scale - icon 16andEXCELL X Series Weighing Scale - icon 36 key to preset values.

For example:
Preset “Low limit” ( Low limit 10d ) e.g. Low limit = 20 kg 
EXCELL X Series Weighing Scale - icon 40

Preset “High limit” ( High limit  Low limit ) e.g. High limit = 25 kg
EXCELL X Series Weighing Scale - icon 41

Preset “Beeper value” ( Refer to Note ) e.g. Beeper value = 22 EXCELL X Series Weighing Scale - icon 42

 

EXCELL X Series Weighing Scale - icon 9  Preset Single point (preset low limit only):
After “preset low limit” procedures is completed and the display showsEXCELL X Series Weighing Scale - icon 30   then press EXCELL X Series Weighing Scale - icon 19key again, the display showsEXCELL X Series Weighing Scale - icon 44 .
. This means that the “preset single point” procedure is completed.
NOTE EXCELL X Series Weighing Scale - icon 45

A Setting for the status that LCD is on and the beeper beep:
0 = when stable, the beeper beeps and LCD is on.
1 = when stable, the beeper beeps; whether stable or not, LCD is on.
2 = whether stable or not, the beeper beeps and LCD is on.
3 = open warning device: when the weight is higher than HI value and the weight is stable, LCD is on and Relay Card open.
B Setting for the beep status:
0 = No beep
1 = OK (when the weight is over Low Limit & under or equal to High Limit.), the beeper beeps.
2 = When the weight is under or equal to Low Limit & over High Limit, the beeper beeps.
EXCELL X Series Weighing Scale - icon 9 Under Status in Preset Low Limit (preset single point only)
The BEEP, LCD mode should be fixed as follows:EXCELL X Series Weighing Scale - icon 47

EXCELL X Series Weighing Scale - icon 9  Warning device setting (not available in 4/5 key models)
Set HI value and value of the beep, LCD mode should be fixed as follows: EXCELL X Series Weighing Scale - icon 49

When the weight equals to HI value, Relay Card open and the weight is accumulated. Press CE key to dismiss the warning sound and the range of accumulated weight is [000.000]~[999999].
 Clear warning accumulation (not available in 4/5 key models)
 Press key first and then press key to clear all accumulated data.
 Accumulated data is cleared automatically under following conditions
a. when shift among weight mode, counting mode and warning accumulation mode.
b. when shift the units
c. turn off the scale
EXCELL X Series Weighing Scale - icon 9 LCD indication: EXCELL X Series Weighing Scale - icon 50

◆ To exit preset mode, please press key.
2. Recall Check-weighing Values (not available in 4/5/10 key models)EXCELL X Series Weighing Scale - fig.

3. Clearing Check-weighing Values (not available in 4/5/10 key models)
PressEXCELL X Series Weighing Scale - icon 19 key then pressEXCELL X Series Weighing Scale - icon 12 key, and then press key CE Recall “Low limit
value”. Then press CE key again EXCELL X Series Weighing Scale - icon 21Clear “High limit value” and “Beeper value”
PressEXCELL X Series Weighing Scale - icon 19 key then pressEXCELL X Series Weighing Scale - icon 36 key 6 times continuously EXCELL X Series Weighing Scale - icon 21Clear all values.
2-2-6 Totalizing (not available in 4/5 key models)

  1. Weight Totalizing
    Place goods on the platter, after stable and press key to save the weight value.
    Then the display shows the total number of additions and the totalized weight value.
    And the (M+) indication “▼” will flash on the display. The indicator will recover to show the weight value of the goods on the platter after 3 seconds and the (M+) indication “▼” is on.
    EXCELL X Series Weighing Scale - icon 9 The indicator allows the next totalizing operation, even when the weight value does not return back to zero. The
    key is functional, when the weight value changes by more
    than 10d. The indicator will save the totalized weight value after the weight is stable.
    EXCELL X Series Weighing Scale - icon 9The indicator can totalize positive or negative weight but can’t do both at the same time.
    The totalized weight store must be reset to zero before it is possible to select positive or negative totalizing mode.
    EXCELL X Series Weighing Scale - icon 9The totalizing function can be used up to a maximum of 9999 times before it must be reset. The totalizing display is limited to 6 digits maximum.
    EXCELL X Series Weighing Scale - icon 9 When totalizing, RS-232 will also output. ( Refer to F5 setting)
  2. Clear Totalized Weight Values (not available in 4/5 key models)
     Press EXCELL X Series Weighing Scale - icon 12 then CE key to clear all totalized weight values.
     When changing between weighing and counting mode, or selecting weighing unit, the indicator will automatically clear all the totalized weight values.
     The indicators will automatically clear all the totalized weight values after turning on.
  3. Recall Totalized Weight Values (not available in 4/5 key models)
    Press EXCELL X Series Weighing Scale - icon 12key to display the total number of additions and the totalized weight value. And the (M+) indication “” will flash on the display. The indicator will return to the weighing mode after 3 seconds.
     The indicator will not display the negative sign “▼-” for negative totalized weight values  when recalling a totalized weight value, but when printing, the negative sign “-” will beprinted out (transmitted serially) for each negative weight and negative totalized weight.

2-3 Counting Function (not available in 4/5 key models)
2-3-1 Sampling

  1. PressEXCELL X Series Weighing Scale - icon 53 key to select sample quantity from 10, 20, 50,100
  2. Select sample quantity and then place samples on the platter, and then pressEXCELL X Series Weighing Scale - icon 17 key, the display shows “    EXCELL X Series Weighing Scale - icon 51
  3.  After stable, the scale enters into counting mode and the display shows sample quantity.
    Sample Too Small EXCELL X Series Weighing Scale - icon 5
    Sample is less than 20 divisions.EXCELL X Series Weighing Scale - icon 55Sample is less than 20 divisions.
     Unit weight is less than 0.2 division. (0.1 d for Brazil regulation)
    EXCELL X Series Weighing Scale - icon 9When sampling, the above two symbols indications are on. Under such conditions, the scale can still work, but may result in lower count precision.
    EXCELL X Series Weighing Scale - icon 9 When using 2-segment weighing mode, the above two symbol indications change to Range 2 and Range 1 and the two symbol indications are off.

2-3-2 Check Weighing
Refer to the operation of check weighing in weighing function.
2-3-3 Totalizing
Refer to the operation of totalizing in weighing function.

Chapter 3 General Function Setting

  • Switch on the scale. While the scale is counting down to zero, press and holdEXCELL X Series Weighing Scale - icon 7 key until the display shows the software version number 02036. Release the EXCELL X Series Weighing Scale - icon 7key, the scale enters into the configuration setting mode and display F0.

EXCELL X Series Weighing Scale - icon 56

3-1 F4 Check Weighing Configurations EXCELL X Series Weighing Scale - icon 57

3-2 F5 RS-232 Output Setting (Option) EXCELL X Series Weighing Scale - icon 58

RS-232 Interface Format

  1. Mode: UART Signal of EIA-RS0232 C
    II . Format : 1. Baud rate : 1 200, 2 400, 4 800, 9 600 bits/second
  2. Data bits : 8 bits
  3. Parity bit : None
  4. Stop bits : 1 bit
  5. Code  : ASCII (Exchange code of American standard) EXCELL X Series Weighing Scale - icon 59

RS-232 Data Format
Command mode (r n P 0)

Command Function Return message definition
C T <CR> <LF>   Clear tare N P <CR> <LF> already pre-tared
    C T <CR> <LF> successful
M T <CR> <LF>   Tare N P <CR> <LF> already pre-tared
    M T <CR> <LF> successful
N S <CR> <LF> unstable
M Z <CR> <LF>   Zero N P <CR> <LF> already pre-tared
    N T <CR> <LF> already tared
M Z <CR> <LF> successful
N Z <CR> <LF> outside zero range
N S <CR> <LF> unstable
R W <CR> <LF>   Read Weight Return weight format as (r n p1)
     
P T , 0 0 0 1 0 0 <CR> <LF> Set pre-tare N O <CR> <LF> exceed number of digits
L O , 0 0 0 1 0 0 <CR> <LF> Set low limit N N <CR> <LF> non-numeric value
H I , 0 0 0 1 0 0 <CR> <LF> Set high limit N G <CR> <LF> over max weight
  N D <CR> <LF> Increment d is incorrect

Stable transmission (r n P 1), Continuous (r n P 2), PressEXCELL X Series Weighing Scale - icon 36 key to transmit (r n P 8) EXCELL X Series Weighing Scale - icon 60

HEAD1 ( 2 BYTES ) HEAD2 ( 2 BYTES )
OL    –     Overload , Under load TR    –     TARE Mode
ST    –     Display is Stable NT   –     NET Mode
US    –     Display is Unstable GS    –     GROSS Mode

DATA ( 7 or 8 BYTE )
2B ( HEX ) = “ + ” ( PLUS)
2D ( HEX ) = “ – ” ( MINUS )
2E ( HEX ) = “ . ” ( DECIMAL POINT )
UNIT ( 2、3 or 4 BYTE )
kg = 6B ( HEX ) ; 67 ( HEX )
lb = 6C( HEX ) ; 62 ( HEX )
tl.T = 74 ( HEX ) ; 6C ( HEX ) ; 2E ( HEX ) ; 54 ( HEX )
hkg = 68 ( HEX ) ; 67 ( HEX )
viss = 76 ( HEX ) ; 69 ( HEX ) ; 73 ( HEX ) ; 73 ( HEX )
Transmission examples: (r n P 2) RS-232 continuous transmission EXCELL X Series Weighing Scale - icon 61

Press EXCELL X Series Weighing Scale - icon 36 key to transmit simple format (r n P 3) EXCELL X Series Weighing Scale - icon 62

PressEXCELL X Series Weighing Scale - icon 36 key to transmit complete format (r n P 4)
TICKETS NO. 0001
G 1.000kg
T 0.000kg
N 1.000kg
(3 blank lines)EXCELL X Series Weighing Scale - icon 64

TICKETS NO. 0002G 1.000kg
T 0.000kg
N 1.000kg
(3 blank lines)EXCELL X Series Weighing Scale - icon 64

TICKETS NO. 0003
G 1.000kg
T 0.000kg
N 1.000kg
(3 blank lines)EXCELL X Series Weighing Scale - icon 64

 

TOTAL NUMBER
OF TICKETS 0003
TOTAL
NET 3.000kg
(3 blank lines)SVEN PS-770 Party Speaker System with Bluetooth and FM Radio - Connesction

EXCELL X Series Weighing Scale - icon 9 G = GROSS T = TARE N = NET
Stable Transmission in totalizing mode (r n P 5)  EXCELL X Series Weighing Scale - icon 67

Press EXCELL X Series Weighing Scale - icon 36key to transmit simple free format (r n P 6)
Same format as (r n P 3). Print the complete format for the first time. Then only print NET weight.
Please refer to F14 for details.
PressEXCELL X Series Weighing Scale - icon 36 key to transmit complete free format (r n P 7) Same format as (r n P 4). Print the complete format all the time. Please refer to F14 for details.
RS232 output format in HOLD MODE
Please set (r n P 8) in F5. If there is only RS-232, pressEXCELL X Series Weighing Scale - icon 36 to print out the HOLD value on the display.

      1 . 0 0 0 k g <CR> <LF>

Print after Removing Goods (5% mode) (r n P 11)

Stage Condition(s) Action(s)
1: Goods placed and weighed on platter Weight has become stable. Weight > zero point

Weight ≥ 20 weighing units

(i.e. 5% x Weight ≥ 1 weighing unit)

Beeper   beeps  twice,   and printing data (stable weight

compliant with conditions on the left) is ready to be sent.

2: Just removed goods from platter Instantaneous weight reading drops below 95% of last stable weight (stable weight of Stage 1) Printing data of Stage 1 is sent to the printer (same printing formats as those of

(r n P 1).

Print after Removing Goods (OK mode) (r n P 12)

Stage Condition(s) Action(s)
1: Goods placed and weighed on platter Weight has become stable. Weight > zero point

Check weighing OK status (within a predetermined weight range)

Beeper beeps twice, and printing data (stable weight compliant with conditions on

the left) is ready to be sent.

2: Just removed

goods from platter

Instantaneous weight reading drops

below 95% of last stable weight (stable weight of Stage 1).

Printing data of Stage 1 is

sent to the printer (same printing formats as those of

(r n P 1).

Continuous transmission, bluetooth format (r n P 13)

HEAD1 ( 2 BYTES ) HEAD2 ( 2 BYTES )
OL    –     Overload , Under load N   –     TARE Mode
ST    –     Display is Stable G   –     NET Mode
US    –     Display is Unstable GS    –     GROSS Mode

DATA (8 BYTE )
2B ( HEX ) = “ + ” ( PLUS)
2D ( HEX ) = “ – ” ( MINUS )
2E ( HEX ) = “ . ” ( DECIMAL POINT )
UNIT (3 BYTE )
‘ ‘kg; ‘ ‘lb; tlT; hkg; vis

  1. The gross weight (+0.876 kg) shows as below, after stable: (no tare or pre-tare mode)EXCELL X Series Weighing Scale - icon 69 Stable transmission only weight value is transmitted (r n P 14)No +/-. If display is 1.000kg , transmit

EXCELL X Series Weighing Scale - icon 70

 

F5

 

Function

Press key PressEXCELL X Series Weighing Scale - icon 1ccc key  

Press       EXCELL X Series Weighing Scale - icon 1ccc    key twice after zeroing

r n p 0 RS232 command mode Once received read weight command, transmit weight in same format as r n p 1.
r n p 1 Stable transmission After return to zero, transmit next stable weight.
r n p 2 Continuous transmission. RS232 transmit continuously. Keypad has no effect.
r n p 3 Press  EXCELL X Series Weighing Scale - icon 36 key to transmit simple format Transmit when weight change

>±10d,

Transmit when weight change

>±10d,

Print TOTAL and clears totalized

values

r n p 4 Press EXCELL X Series Weighing Scale - icon 36   key to transmit complete format. Transmit when weight change

>±10d,

Transmit when weight change

>±10d,

Print TOTAL and clears totalized values
 

r n p

 

5

Stable transmission in totalizing mode (After return to zero, transmit next stable weight which

is > +10d)

 

No transmission

 

No transmission

Print TOTAL and clears totalized values
 

r n p

 

6

Press EXCELL X Series Weighing Scale - icon 36   key to transmit simple free format Transmit when weight change

>±10d,

Transmit when weight change

>±10d,

Print TOTAL and clears totalized values
 

r n p

 

7

Press    EXCELL X Series Weighing Scale - icon 36 key to transmit complete free format Transmit when weight change

>±10d,

Transmit when weight change

>±10d,

Print TOTAL and

clears totalized values

 

r n p

 

8

Press     EXCELL X Series Weighing Scale - icon 36      key to transmit same format as (r n P 1) and (r n

P 2)

 

No transmission

Transmit as stable weight

>±10d

No transmission, totalized values not cleared
 

r n p

 

9

 

Continuous Transmission (Brazil)

 

Continuous transmission

 

Continuous transmission

Continuous transmission, totalized values not

cleared

EXCELL PRECISION CO., LTD. 

 

r n p 10

 M+  or   EXCELL X Series Weighing Scale - icon 36  key

Transmission (Brazil)

 

RS232 transmit

 

RS232 transmit

Print TOTAL and

clears totalized values

r n p 11 Print after removing goods (5% mode) After placing item and become stable, beep twice. RS232 transmit item weight after item is removed.
r n p 12 Print after removing goods (OK mode) RS232 transmit only “OK” item weight after item is removed. No transmission while in “HI” or “LO”.
r n p 13 Continuous transmission, bluetooth format Bluetooth transmit continuously through RS232. Keypad has no effect.
r n p 14 Stable transmission, only weight value is transmitted After return to zero, transmit next stable weight’s weight value only.

3-3 F6 Exit Function
UseEXCELL X Series Weighing Scale - icon 71to select F6. Then press EXCELL X Series Weighing Scale - icon 36to count down to zero and exit the setting.
3-4 F7 Internal Value Display Mode 
Use EXCELL X Series Weighing Scale - icon 75 orEXCELL X Series Weighing Scale - icon 11 to select F7. Then pressEXCELL X Series Weighing Scale - icon 36 to display internal value. PressEXCELL X Series Weighing Scale - icon 36  again will see F7.
 3-5 F8 Weight Hold Mode Setting EXCELL X Series Weighing Scale - icon 73

 Before setup, please switch the SWA1 on MINI JUMPER to ADJ position
 After setup, please switch the SWA1 on MINI JUMPER back to LOCK position
EXCELL X Series Weighing Scale - icon 9  In hold mode, pressEXCELL X Series Weighing Scale - icon 36 key, to print the hold value as shown on display. (It’s not related to the settings of F5 transmission mode, but it needs to select the  proper Baud rate according to the transmission of the receiver.)
(To setup transmission rate, please refer to F5 RS-232 Interface Output Setting (option))
UseEXCELL X Series Weighing Scale - icon 75  key to select a value from hold 0 ~ hold 4 and then pressEXCELL X Series Weighing Scale - icon 36 key to complete setup.
hold 0 = No hold function
hold 1 = For varying weighing value, the scale will automatically hold the maximum weighing value to display. To exit hold mode, press any key (except the EXCELL X Series Weighing Scale - icon 36key).
hold 2 = After the scale is stabilized, the scale will automatically hold the display value( not changeable due to external variables)To exit hold mode, press any key.( except the EXCELL X Series Weighing Scale - icon 36key )
hold 3 = After the scale is stabilized, the scale will automatically hold the display value( not changeable due to external variables).After zero return ( or weight is less than 10d), the scale exits the hold mode automatically.
hold 4 = Animal Scale function. When animal is on the scale platter and is stable, the scale will automatically hold the display value (not changeable due to external variables). After the animal is off the scale platter, the scale exits the hold mode automatically.
Animal Scale Hold Setup (hold 4) EXCELL X Series Weighing Scale - icon 80

3-6 F11 ID Code Setting
(must be used with r n P 1, r n P 2, r n P 8 of F5)EXCELL X Series Weighing Scale - icon 81

RS232 DATA FORMAT
Stable transmission (r n P 1), Continuous (r n P 2), Press EXCELL X Series Weighing Scale - icon 36key to transmit (r n P 8) EXCELL X Series Weighing Scale - icon 94

3-7 F12 Print Key ( EXCELL X Series Weighing Scale - icon 36) Function Setting EXCELL X Series Weighing Scale - icon 92

3-8 F14 Customized Header Setting (r n P 6, r n P 7) 

CODE Description CODE Description
0 No print. 6 P/N
1 TICKET NO. 7 S/N
2 G 8 DATE (Note: need FB53’s MINI_PRINTER to print)
3 T 9 TIME (Note: need FB53’s MINI_PRINTER to print)
4 PT A PCS
5 N    

F14 contains a 9-digit code. For example: 6 1 2 3 4 5 0 0 0 ○1
F5 = r n P 6 Simple Free Format ○2
F5 = r n P 7 Complete Free Format

EXCELL X Series Weighing Scale - icon 96

EXCELL X Series Weighing Scale - icon 9 After power-off, S/N will reset as 1. P/N will be saved in memory, available during next power-on.

Appendix 1 Option Card Description

RS232 Output
1. Weighing scale (AW, HW, FD, RW, TW)
RS232 card’s 6PIN cable connect to CN3 of mainboardEXCELL X Series Weighing Scale - icon 86

Relay Output
Principle of Relay operation
Use checkweighing pre-set EXCELL X Series Weighing Scale - icon 19key (TW, AW) or though F4 from the menu (TW, AW, RW, HW) to get in checkweighing mode to set the HIGH and LOW limit points. Between HIGH and LOW limits are OK range.
If the weight is below LOW limit, the data will output in LOW port;
If the weight is between HIGH and LOW limits (OK range), the data will output in OK port;
If the weight is above HIGH limit, the data will output in HIGH port
 Please refer to the operation of Pre-setEXCELL X Series Weighing Scale - icon 19 key and F4 function.

Weighing scale (AW, HW, FD, RW, TW)

  1. PIN definitionEXCELL X Series Weighing Scale - icon 87
  2. ConnectionEXCELL X Series Weighing Scale - icon 100
  3.  Power supply for Relay
    The power supply of the RELAY card is a dual power supply option (5V and 12V) supplied by the system itself. It can also use an external power supply. If so, please open circuit at JP1 and short circuit at JP2.
    The factory default is 5V power supply. To use 12V power supply, please short circuit J12.
  4.  Configuration
    OK, High, and Low can be set to NO (normally open, J2, J3, J5) or NC (normally closed, J1, J4, J6). The default value is NO (normally open, J2, J3, J5)
     OK, High, and Low are NO (normally open, J2, J3, J5)  defaultEXCELL X Series Weighing Scale - icon 101 OK, High, and Low are NC (normally close, J1, J4, J6)
    Make J1, J4, J6 open circuit by cutting the circuit. Then make J2, J3, J5 short circuit with solder.EXCELL X Series Weighing Scale - fig34Restore factory settings when RJ45 option card is installed
    If scale does not work properly after modifying setting through RJ45 card, please follow the steps below to restore to factory setting.
    In the weighing mode, hold theEXCELL X Series Weighing Scale - icon 36 key while pressEXCELL X Series Weighing Scale - icon 7 key at the same time (within 1 second). Then release key, and “RELOAD” appears. When reloading end, please restart the scale to restore to the factory settings.

Appendix 2 Load Cell PIN

EXCELL X Series Weighing Scale - icon 9 For indicators only

EXCELL X Series Weighing Scale - fig 63

Appendix 3 7-Segment Display Characters EXCELL X Series Weighing Scale - fig 52

EXCELL X Series Weighing Scale - QR

EXCELL X Series Weighing Scale - icon V22. 1222 6F, No. 127, Lane 235, Baoqiao Rd., Xindian District, New Taipei City 23145, Taiwan
pm-all@Wexcell.conn.tw
ASHLEY D291-25 Parellen Dining Table - icon 2 +886-2-8919-1000
icon https://www.excell-scale.com
EXCELL X Series Weighing Scale - icon 4 +886-2-8919-2209

Documents / Resources

EXCELL X Series Weighing Scale [pdf] User Manual
V22, X Series Weighing Scale, Weighing Scale, Scale, 1222

References

Leave a comment

Your email address will not be published. Required fields are marked *