algodue logoELETTRONICA MFC190 Rogowski Coil Current Sensor
User Manualalgodue ELETTRONICA MFC190 Rogowski Coil Current Sensor

MFC190
Subject to change without prior notice 

MFC190 Rogowski Coil Current Sensor

PICTURE

algodue ELETTRONICA MFC190 Rogowski Coil Current Sensor - fig

INTRODUCTION

The manual is intended only for qualified, professional and skilled technicians, authorised to act in accordance with the safety standards provided for the electrical installations. This person must have appropriate training and wear  suitable Personal Protective Equipment.
WARNING! It is strictly forbidden for anyone who does not have the above-mentioned requires to install or use the coil.
It is forbidden to use the coil for purposes other than intended ones, specified in this manual. The symbols on the product are following described:

Attention! Refer to the user manual.
Protected throughout by DOUBLE INSULATION or REINFORCED INSULATION.
algodue ELETTRONICA MFC190 Rogowski Coil Current Sensor - icon Do not apply around or remove from HAZARDOUS LIVE conductors without additional protective means.
CE SYMBOL Complies with the relevant European standards.
algodue ELETTRONICA MFC190 Rogowski Coil Current Sensor - icon1 Underwriters’ Laboratory Inc. recognized component.

SAFETY INSTRUCTIONS

The Rogowski coil must be installed in an environment which are according to the max operation conditions of the coil itself.
WARNING! The connection and installation of the Rogowski coil must be carried out only by qualified technicians aware of the risks involved to the presence of voltage and current. Before carrying out an operation, check if:

  1.  bare  conductor wires are not powered, 2. there are no neighbor bare conductors not powered

NOTE: The Rogowski coil complies with UL 61010-1 and UL 610102-032 standards and following amendments. The installation must be carried out in accordance with the standards in force, the instructions of this user manual and the coil insulation value in order to avoid any danger for people.
The Rogowski coil is a sensor for accurate measurement so it must be handled with care. Before use, read the following instructions carefully.

  • Do not use the product if damaged.
  • Always wear protective clothing and gloves when required.
  • Avoid to strongly twist, blow and to perform pulling load on the product: the measurement accuracy may be impaired.
  • Do not paint the product.
  • Do not put metallic labels or other objects on the product: the insulation may be impaired.
  • It is forbidden any use of the product different from the manufacturer specifications.

MOUNTING

WARNING! Before installing the coil round a conductor not insulated, check that it is not powered otherwise switch the circuit OFF.
WARNING! Check if the coil is properly installed: a bad locking can affect measurement accuracy and the coil will become sensitive to adjacent conductors or other sources of electromagnetic fields.
NOTE: Coil must not fit tightly round  the conductor, therefore its internal diameter must exceed that of the conductor. 
To carry out the installation, proceed as follow:

  1. Fit the coil round the conductor, bringing the coil ends together.
  2. Lock the coil by turning the ring as indicated in picture A.

CONNECTIONS

The coil has an arrow indicating the load side.
Refer to picture B:
A = SOURCE
B = LOAD

  1. WHITE wire, OUT+
  2. BLUE wire, OUT
  3. SHIELD, connect to GND or OUT

If the cable is provided with crimp pins:

  • YELLOW crimp pin, OUT+
  • WHITE crimp pin, OUT-

MAINTENANCE

Refer to the following instructions carefully for the product maintenance.

  • Keep the product clean and free of surface contamination.
  • Clean the product with a soft cloth damp with a water and neutral soap. Avoid to use corrosive chemical products, solvents or aggressive detergents.
  • Make sure the product is dry before further use.
  • Do not use or leave the product in particularly dirty or dusty environments.

TECHNICAL FEATURES

NOTE: For any doubt on the installation procedure or on product application, please contact our technical services or our local distributor.

COIL

Coil length 300 … 3000 mm
Sensor internal diameter 83 … 942 mm
Coil diameter 12.4 ±0.2 mm
Jacket material Thermoplastic polyurethane UL94-V0
Fastening Bayonet holder
Weight 150 … 500 g

ELECTRICAL CHARACTERISTICS

Nominal output rate 333 mV / kA @ 50 Hz (RMS values) Refer to the value indicated on the product label
Max measurable current 65 kA
Coil resistance 300 … 2000 Ω
Positioning error Better than ±1% of reading
Frequency 50/60 Hz
Overvoltage category 1000 V CAT III, 600 V CAT IV
Pollution degree 2
Insulation test voltage 7400 VRMS / 5 s

CONNECTION CABLE

Type 3 x 22 AWG shielded
Length 3 m. Other lengths on request: 5, 7, 10, 15 m

ENVIRONMENTAL CONDITIONS

Protection degree IP67 or IP68 according to the model (not evaluated by UL)
Altitude Up to 2000 m over sea-level
Operating temperature -30 … +80°C
Storage temperature -40 … +80°C
Relative humidity 0 … 95%
Installation and use Indoor

STANDARD COMPLIANCE

IEC, UL standards UL 61010-1 Ed3, UL 61010-2-032, CAN/CSA-C22.2 No. 61010-1, IEC 60529

algodue logoAloud Electronica Sel
Via P. Gaetti, 16/F • 28014 Maggio (NO), ITALY
Tel. +39 0322 89864 • +39 0322 89307
www.algodue.comsupport@algodue.it

Documents / Resources

algodue ELETTRONICA MFC190 Rogowski Coil Current Sensor [pdf] User Manual
MFC190, MFC190 Rogowski Coil Current Sensor, Rogowski Coil Current Sensor, Coil Current Sensor, Current Sensor, Sensor