1. 서론
This manual provides essential information for the proper installation, operation, and maintenance of the Goodman 20162903 160°/120° Primary Limit Switch. This component is designed to ensure the safe and efficient operation of compatible HVAC systems by preventing overheating.
2. 안전 정보
경고: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Read and understand these instructions completely before proceeding. Installation and service must be performed by a qualified installer or service agency.
- Always disconnect electrical power to the appliance before installing or servicing the limit switch.
- 설치 및 서비스 중에는 적절한 개인 보호 장비(PPE)를 착용하십시오.
- 모든 배선 연결이 안전하고 현지 전기 규정을 준수하는지 확인하세요.
- 우회하거나 t하지 마십시오amp어 안전 장치와 함께.
3. 제품 오버view
The Goodman 20162903 is a primary limit switch designed for use in Goodman HVAC systems, typically furnaces. Its function is to monitor the temperature within the heat exchanger or plenum. If the temperature exceeds a preset limit (160°F in this case), the switch will open, interrupting the circuit to the burner and preventing the furnace from overheating. It will reset once the temperature drops to a safe level (120°F).

4. 사양
| 특징 | 사양 |
|---|---|
| 상표 | 굿맨 |
| 부품 번호 | 20162903 |
| 스위치 유형 | XNUMX차 리미트 스위치 |
| 작동 모드 | 오토매틱 |
| 활성화 온도 | 160 ° 화씨 |
| 온도 재설정 | 120 ° 화씨 |
| 커넥터 유형 | Clamp |
| 터미널 유형 | 나사 |
| 재료 | 금속 |
| 품목 치수(L x W x H) | 6.2 x 3.1 x 2.9 인치 |
| 품목 무게 | 1.06 온스 |
| 국제 보호 등급 | IP00 |
| 한국어: | 076335072715 |
5. 설치 및 설정
메모: Installation should only be performed by a qualified HVAC technician.
- 전원 차단: Turn off all electrical power to the furnace or HVAC unit at the main service panel before beginning any work.
- 기존 스위치 찾기: Identify the current primary limit switch in your furnace. It is typically mounted on the heat exchanger or plenum.
- 배선 분리: Carefully disconnect the electrical wires from the terminals of the old limit switch. Note the position of each wire for correct re-connection.
- 이전 스위치 제거: Unscrew or unclip the old limit switch from its mounting location.
- 새로운 스위치 설치: Position the Goodman 20162903 limit switch in the same location as the old one. Secure it using the appropriate screws or clips. Ensure it is firmly mounted.
- 배선 연결: Reconnect the electrical wires to the terminals of the new limit switch, ensuring they match the original configuration. Double-check all connections for tightness.
- 복원력 : Once installation is complete and all connections are verified, restore electrical power to the HVAC unit.
- 테스트 작업: Initiate a heating cycle and monitor the furnace's operation to ensure the new limit switch functions correctly and the furnace operates safely.
6. 작동 원리
The primary limit switch operates automatically. During normal furnace operation, as the heat exchanger heats up, the temperature-sensing element within the limit switch monitors the internal temperature. If the temperature rises above 160°F, the switch will open, interrupting the control circuit to the gas valve or heating element, thereby shutting down the burner. This prevents the furnace from reaching dangerously high temperatures. Once the temperature inside the plenum or heat exchanger cools down to approximately 120°F, the switch will automatically close, allowing the furnace to resume normal operation.
7. 유지관리
The Goodman 20162903 Primary Limit Switch is a sealed component and does not require routine user maintenance. However, it is recommended to have your HVAC system, including safety components like the limit switch, inspected annually by a qualified technician. During inspection, the technician can:
- Check for proper operation of the limit switch.
- 배선에 마모나 손상 흔적이 있는지 검사하십시오.
- 장착이 안전한지 확인하십시오.
- Clean any dust or debris that may accumulate around the switch, which could affect its temperature sensing.
8. 문제 해결
If your furnace is experiencing issues related to overheating or intermittent operation, the primary limit switch may be a factor. Common symptoms of a faulty limit switch include:
- Furnace cycling on and off frequently (short cycling): This can indicate the limit switch is tripping due to restricted airflow, an oversized furnace, or a faulty switch itself.
- Burner shutting off prematurely: If the burner shuts off before the thermostat setting is reached, and the blower continues to run, the limit switch may have tripped.
- No heat or intermittent heat: A completely failed limit switch (stuck open) will prevent the burner from igniting.
If you suspect a problem with your limit switch, it is recommended to contact a qualified HVAC technician for diagnosis and repair. Do not attempt to bypass or repair a faulty limit switch yourself, as this can create a significant safety hazard.
9. 보증 정보
Warranty coverage for the Goodman 20162903 Primary Limit Switch is typically provided by the manufacturer or the seller at the time of purchase. Please refer to your purchase documentation or contact the original vendor for specific warranty terms and conditions. Keep your proof of purchase for any warranty claims.
10. 지원
For technical assistance, troubleshooting beyond this manual, or professional service, please contact a certified HVAC technician or the Goodman customer support line. When contacting support, have your product model number (20162903) and any relevant system information readily available.
굿맨 공식 Web대지: www.goodmanmfg.com