wizardPOS-LOGO

wizarPOS V2.0.0 TMK Local Injection

wizarPOS-V2-0-0-TMK-Local-Injection-PRODUCT

ព័ត៌មានអំពីផលិតផល

  • Product Name: TMK Local Injection System
  • កំណែ៖ V2.0.0
  • Compatibility: Works with dedicated Key Injection Devices (KLD) such as WizarPOS 1 or WizarPOS Q2/Q3

ការណែនាំអំពីការប្រើប្រាស់ផលិតផល

មគ្គុទ្ទេសក៍ចាប់ផ្តើមរហ័ស

  1. ភ្ជាប់ឧបករណ៍៖ Use a USB cable to connect the target POS to the appropriate port on the Key Injection Device.
  2. Start Target POS KLD Agent: Ensure Administrator state is ‘Login’, navigate to System Setting -> About POS -> POS Configuration -> Load Key, click Load Key.
  3. Initiate Injection: On the Key Injection Device, press OK to enter the Key Injection Menu, select Offline Deliver, and enter the deliver password.
  4. ជ្រើសរើសគន្លឹះ៖ Follow on-screen prompts to locate the key using its identifiers.
  5. Configure Injection: Specify the key index and, for DUKPT keys, the key usage.
  6. Confirm and Inject: Review key information and confirm the injection.
  7. Upon success, a receipt will print, and both devices will display a success message.

ប្រតិបត្តិការប្រព័ន្ធ

Login and Idle Screen

  • Access this menu by pressing 5 on the IDLE screen.
  • The default administrator password is 87654321.

System Management Menu

  • This menu can be accessed by pressing 5 on the IDLE screen.
  • The default administrator password is 87654321.

Key Injection Menu

  • To access this menu, press OK or Cancel on the IDLE screen.
  • The default delivery password is 00000000.

Detailed Key Injection Procedures

  1. Connect the Key Injection Device to the PC via a DB9 serial cable/USB-to-DB9 adapter (For WizarPOS 1) or USB/UU cable(For Q2,Q3).
  2. Open the Key Tool on the PC and ensure the correct serial port is selected.
  3. On the Key Injection Device, select Key Load. The device enters a receiving state.
  4. On the PC’s Key Tool, load the key file and click Key Offline Load to transmit the keys.
  5. Verify the loaded keys via the Key Query menu.

សេចក្តីផ្តើម

ជាងview

  • The TMK (Terminal Master Key) Local Injection System is an application pre-installed on a dedicated Key Injection Device or KLD (typically a WizarPOS 1 or WizarPOS Q2/Q3 unit).
  • This system allows payment administrators to securely inject cryptographic keys into standard payment terminals (target POS).

Key Injection Methods

The system supports three primary methods for key injection:

  1. Local Injection from Device Storage (offline deliver): Keys are first loaded into the Key Injection Device (via manual input or from a PC) and then injected locally into the target POS.
  2. Manual Local Injection: Key components are manually entered directly into the Key Injection Device, which then injects the derived key into the target POS.
  3. Injection Direct from PC (online deliver): Keys are sent directly from a PC application through the Key Injection Device to the target POS in real-time. This method is only supported on WizarPOS 1.

មគ្គុទ្ទេសក៍ចាប់ផ្តើមរហ័ស

This guide outlines the most common workflow: Offline Injection using a key previously stored on the device.

  1. Prepare the Key: Ensure the target key is already stored on the Key Injection Device. This can be done by:
    • Manual Input: See Section 3.2.4 Input Key.
    • Loading from PC: See Section 3.3.1 Key Load
  2. Connect Devices: Use a USB cable to connect the target POS to the appropriate port on the Key Injection Device (see Section 5 Device Connection Guide).
  3. Start Target POS KLD Agent: On the target POS, make sure Administrator state is ‘Login’ (default pass: 99999999), navigate to System Setting -> About POS -> POS Configuration -> Load Key. click Load Key, the device will enter a waiting state.
  4. Initiate Injection: On the Key Injection Device, from the idle screen, press OK to enter the Key Injection Menu. Select Offline Deliver and enter the deliver password (default: 00000000).
  5. Select Key: Follow the on-screen prompts to locate the key using its identifiers (e.g., MID/TID, KSI, KID).
  6. Configure Injection: Specify the key index (0-49) on the target POS and, for DUKPT keys, the key usage.
  7. Confirm and Inject: Review the key information and confirm the injection. Upon success, a receipt will print, and both devices will display a success message.

ប្រតិបត្តិការប្រព័ន្ធ

  • Login and Idle Screen
    • Upon startup, the application requires two login passwords.wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (1)
    • Default Login Password 1: 11111111
    • Default Login Password 2: 22222222
    • After successful authentication, the system enters the IDLE screen, displaying version information.wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (2)
  • From IDLE Screen:
    • Press 5 to enter the System Manage menu (default pass: 87654321).
    • Press OK or Cancel to enter the Key Injection menu.wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (3)wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (4)

System Management Menu

  • Access this menu by pressing 5 on the IDLE screen. The default administrator password is 87654321.

KEK Setting

  • Purpose: The Key Encryption Key (KEK) is used to encrypt keys during communication with the PC or manual enter TR31 key block. It is only required for Key Load, Online Delivery and Manul Enter TR31 Key functions.
  • Setup: KEK is divided into two components. Each component requires a password for setting.
    • Default Component 1 Password: 88888888
    • Default Component 2 Password: 99999999
    • Default Component 3 Password: 77777777
  • ចំណាំ៖ if the KEK components to be entered less than 3, keep the following component as all zero.

Deliver Type

  • គោលបំណង៖ This setting defines the model of the target POS terminal. It must be configured correctly before any injection attempt.
  • ជម្រើស៖
    1. Wizarhand Q1v1: For older Q1 model terminals.
    2. PINPAD: For external PINPAD devices.
    3. Others: For WizarPOS Q2, Q3, and other modern models.wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (5)

ប្រភេទសោ

  • គោលបំណង៖ Specifies the cryptographic algorithm and type of key to be injected. This must be set before manually inputting a key or performing an offline injection.
  • Supported Types include: MASTER KEY (3DES/AES/SM4), DUKPT-IPEK, DUKPT-BDK(3DES/AES), TRANSMISSION KEY(3DES/AES/SM4), HSM KEY (DES/3DES/AES/SM4).wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (6)

គ្រាប់ចុចបញ្ចូល

Use this function to manually enter and store a key on the device.

  1. Prerequisite: Set the correct Key Type first.
  2. Enter Identifiers: The system will prompt for specific identifiers based on the key type:
    • MID & TID: For MASTER KEY, DUKPT-IPEK, TRANSMISSION KEY. (Use any values if not applicable, but note them for future reference.)
      KSI (First 10 digits of KSN): For DUKPT-BDK.
      KID (4 digits): For all HSM KEY types.
  3. Enter Key Components: Input the key split into its components. The system will display a check value to verify correct entry.
  4. The key is now stored locally and available for Offline Delivery.

Password Modify

  • Allows changing of all system passwords:
  • ពាក្យសម្ងាត់អ្នកគ្រប់គ្រង
  • Deliver Password
  • Login Passwords (1 & 2)
  • Component PasswordswizarPOS-V2-0-0-TMK-Local-Injection-FIG- (7)

Key Injection Menu

  • Access this menu by pressing OK or Cancel on the IDLE screen. The default deliver password is 00000000.

ការផ្ទុកគ្រាប់ចុច

  • គោលបំណង៖ Transfers keys from the PC-side Key Tool application to the Key Injection Device’s local storage.
  • តម្រូវការជាមុន៖ KEK must be set.
  • ជំហាន៖
    1. Connect the Key Injection Device to the PC via a DB9 serial cable/USB-to-DB9 adapter (For WizarPOS 1) or USB/UU cable(For Q2,Q3).
    2. Open the Key Tool on the PC and ensure the correct serial port is selected.
    3. On the Key Injection Device, select Key Load. The device enters a receiving state.
    4. On the PC’s Key Tool, load the key file and click Key Offline Load to transmit the keys.
    5. Verify the loaded keys via the Key Query menu.wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (8)wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (9)
  • ការផ្ទុកគ្រាប់ចុច
  • គោលបំណង៖ Transfers keys from the PC-side Key Tool application to the Key Injection Device’s local storage.
  • តម្រូវការជាមុន៖ KEK must be set.
  • ជំហាន៖
    1. Connect the Key Injection Device to the PC via a DB9 serial cable/USB-to-DB9 adapter (For WizarPOS 1) or USB/UU cable(For Q2,Q3).
    2. Open the Key Tool on the PC and ensure the correct serial port is selected.
    3. On the Key Injection Device, select Key Load. The device enters a receiving state.
    4. On the PC’s Key Tool, load the key file and click Key Offline Load to transmit the keys.
    5. Verify the loaded keys via the Key Query menu.

Key Clear

  • Permanently deletes all keys from the Key Injection Device’s local storage.

Detailed Key Injection Procedures

  • Inject from Key Injection Device (Offline Deliver)
  • Prerequisite: Verify the key exists in the device’s storage (check Key Query).
    1. Connectivity: Connect the target POS to the Key Injection Device via the appropriate USB cable.
    2. Start Target Agent: On the target POS, make sure Administrator state is ‘Login’ (default pass: 99999999), open the Key Loader Agent (Path: System Setting -> About POS -> POS Configuration -> Load Key). and press Load Key to enter a waiting state.wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (10)
    3. Start Injection: On the Key Injection Device, select Offline Deliver and enter the deliver password (default pass: 00000000).wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (11)
    4. Locate Key: Input the key’s identifiers (MID/TID, KSI, or KID) as prompted to find the key.
    5. Additional Data (if applicable):
      1. For DUKPT-BDK, you will be prompted to enter the DID (part of the KSN).
      2. For DUKPT keys, you will be prompted to select the Key Usage (PIN-Key, MAC-Key, Data-Key, or Reserved). Selecting Reserved allows the target HSM to derive keys per DUKPT2009 specification.
    6. Set Key Index: Specify the key index (0-49) on the target POS’s HSM where the key will be stored.
    7. Confirm and Inject: Review all parameters and confirm to start the injection. Success will be indicated on-screen messages.
  • Inject from PC (Online Deliver – WizarPOS 1 only)
    1. Connectivity: Connect the Key Injection Device to the PC via a DB9 serial cable. Connect the target POS to the Key Injection Device via a USB cable.
    2. Prerequisite: Ensure KEK is set correctly on the Key Injection Device.
    3. Start Target Agent: On the target POS, make sure Administrator state is ‘Login’ (default pass: 99999999), open the Key Loader Agent (Path: System Setting -> About POS -> POS Configuration -> Load Key). and press Load Key to enter a waiting state.wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (12)
    4. Initiate Online Delivery: On the Key Injection Device, select Online Deliver and enter the deliver password. The device will enter a waiting state.wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (13)
    5. Send Key from PC: On the PC’s Key Tool, load the key file and use the Key online delivery function to send the key.wizarPOS-V2-0-0-TMK-Local-Injection-FIG- (14)
    6. ការណែនាំអំពីការភ្ជាប់ឧបករណ៍
  • WizarPOS Q2/Q3 as Key Injection Device
    • Connection to Target POS: Use a USB cable connected to the OTG/TYPE A port.
    • Note: The Q2/Q3 device does not support the Online Delivery functions.

WizarPOS 1 as Key Injection Device

  • Connection to Target POS:
    • For PINPAD: Use an RJ11 cable connected to the RJ11 LINE2 port.
    • For All Other Types (Q1v1, Others): Use a USB cable connected to the USB TYPE A port.
  • Connection to PC: Use a DB9 serial cable (or USB-to-DB9 adapter) connected to the DB9 SERIAL PORT. Required for Key Load and Online Delivery.
Security and Recommended Usage
To ensure the highest level of security, adhere to the following practices:
  1. Dual Custody: The two login passwords should be held by two different key custodians. Both custodians must be present to operate the system.
  2. Change Default Passwords Immediately: Upon first use, change all default passwords (login, administrator, deliver, component).
  3. Compartmentalization of Knowledge: Each key custodian should only know their own login password and key components. No single person should possess all credentials.
  4. Full-Length Components: Each key component must be of full length, identical to the complete key length.
  5. Physical Security: The Key Injection Device should be stored in a secure, access-controlled room and must never be connected to any network.
  6. Audit Logging: Maintain a detailed log of every operation performed using the TMK Local Injection System, including date, time, custodians involved, and target terminal IDs.

ព័ត៌មានបន្ថែម

សំណួរដែលសួរញឹកញាប់

Q: What is the default password for accessing the system management menu?

A: The default administrator password is 87654321.

Q: How can I delete all keys stored in the local storage of the Key Injection Device?

A: You can permanently delete all keys by selecting Key Clear from the Key Injection Menu.