ZKTeco SpeedFace-V4L Pro Series
Installation Guide
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
Installation Environment
Please refer to the following recommendations for installation:
- [Indoor Installation Only] ?
- [Avoid Installation Near Glass Windows] ?☀️
- [Avoid Direct Sunlight and Exposure] ☀️
- [Avoid Use of Any Heat Source Near the Device] ?
- Avoid direct contact to sunlight for a long time.
- Protect the device from moisture, water, and rain.
- Handle the device with care.
- Ensure that the device is not installed near the sea or in other locations where metal oxidation and rust may develop if the device is exposed for an extended period.
- Protect the device from lightning. ⚡
- Ensure that the device only works in an acidic or alkaline environment briefly.
How to Install the Device on the wall?
Step 1: Stick the wall-mounting template to the wall and drill holes according to the wall-mounting template.
Place the mounting template on the desired wall location. Ensure the template is level. Mark the positions for drilling holes. The recommended height from the ground is 1450mm, adjustable based on average user height. Drill holes for mounting and wiring as indicated on the template. Ensure drilling is done at a 90° angle. Recommended hole diameter is 6mm, with a 30mm distance from the edge.
Step 2: Insert the expansion tubes into the mounting holes.
Insert the provided expansion tubes into the drilled holes on the wall.
Step 3: Attach the backplate on the wall using the wall mounting screws.
Note: Please insert the wire through the backplate before installation. Secure the backplate to the wall using the wall mounting screws.
Step 4: Attach the terminal to the backplate.
Align the device terminal with the backplate and slide it into place.
Step 5: Attach the terminal to the backplate with a security screw.
Secure the device to the backplate by tightening the security screw using a screwdriver. ?️
Device Connections
Door Bell, Exit Button and Alarm Connection
Exit Button / Door Sensor Wiring:
| Terminal | Connection |
|---|---|
| WD1 | GND |
| WDO | +12V |
| GND | ID1 |
| GND | ID0 |
| BELL- | 485A |
| BELL+ | 485B |
| SEN | GND |
| BUT | NC |
| AUX | COM |
| GND | NO |
| AL- | AL+ |
Bell Power: Connect the positive (+) terminal to BELL+ and the negative (-) terminal to BELL-.
Door Bell: Connect the positive (+) terminal to BELL+ and the negative (-) terminal to BELL-.
Alarm: Connect the positive (+) terminal to AL+ and the negative (-) terminal to AL-. This connection also applies to the Alarm's Power Switch.
Door Sensor and Smoke Detection Connection
Door Sensor Wiring: (Refer to the table above for WD1, WDO, GND, BELL-, BELL+, SEN, BUT, AUX, GND, AL- terminals.)
Smoke Detector: Connect the positive (+) terminal to AL+ and the negative (-) terminal to AL-.
Power Connection
Connect the device to a power source using the GND and +12V terminals.
Recommended Power Supply: 12V ± 10%, at least 3000mA.
To share the power with other devices, use a power supply with higher current ratings.
RS485 and Wiegand Connection
RS485 Reader Connection:
| Terminal | Connection |
|---|---|
| WD1 | GND |
| WDO | +12V |
| GND | ID1 |
| GND | ID0 |
| BELL- | 485A |
| BELL+ | 485B |
| SEN | GND |
| BUT | NC |
| AUX | COM |
| GND | NO |
| AL- | AL+ |
Wiegand Reader Connection:
| Terminal | Connection |
|---|---|
| GND | GND |
| +12V | +12V |
| WD1 | WD1 |
| WDO | WDO |
Ethernet Connection
Connect the device to a network using an RJ45 Ethernet cable. This allows connection to a PC. ?
Default IP Address: 192.168.1.201, Subnet Mask: 255.255.255.0
Configured IP Address: 192.168.1.130, Subnet Mask: 255.255.255.0
To configure the IP address: Click COMM. > Ethernet > IP Address on the device, input the desired IP address, and click OK.
Lock Relay Connection
The system supports both Normally Opened (NO) Lock and Normally Closed (NC) Lock configurations. ?
- NO LOCK (normally opened at power on) connects to "NO1" and "COM" terminals.
- NC LOCK (normally closed at power on) connects to "NC1" and "COM" terminals.
The following describes the connection for an NC Lock:
Device not sharing power with the lock:
Connect the lock relay to the device terminals (GND, +12V, ID1, ID0, 485A, 485B, GND, NC, COM, NO, AL+) and a DC12V power supply. A FR107 component is used in the circuit.
Device sharing power with the lock:
Connect the lock relay to the device terminals (GND, +12V, ID1, ID0, 485A, 485B, GND, NC, COM, NO, AL+) and a DC12V power supply. A FR107 component is used in the circuit.
Download Center
Scan the QR Code to download the User Manual, Installation Guide, and Quick Start Guide.
[QR Code for Download Center]
Contact Information
ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China.
Phone: +86 769 - 82109991
Fax: +86 755 - 89602394
Website: www.zkteco.com
Copyright © 2023 ZKTECO CO., LTD. All Rights Reserved.