Guide for APEX WAVES models including: PCIe-6612 Counter-Timer Module, PCIe-6612, Counter-Timer Module, Module
PCIe-6612 National Instruments Counter/Timer Device | Apex Waves
File Info : application/pdf, 4 Pages, 1.41MB
DocumentDocumentPCIe-6612 NOTE TO USERS NI 66xx Pinout Labels for the SCB-68A Counter/Timer Modules/Devices Using the 68-Pin Shielded Connector Block If you are using an NI 66xx (formerly referred to as TIO) counter/timer device or module with the SCB-68A, you can print and attach a connector-specific pinout label to the cover of the connector block for easy connection reference. This document provides the label for the following models: · NI 6601 · NI 6602 · NI 6608 · NI 6612 · NI 6614 Use the following label if you are connecting the SCB-68A to NI 6601, NI 6602, and NI 6608 models. Figure 1. NI 660x DIO/CTR 68 D GND 34 PFI 31/P0.31/CTR 2 SOURCE 67 PFI 30/P0.30/CTR 2 GATE 33 D GND 66 PFI 29/P0.29/CTR 2 AUX 32 PFI 28/P0.28/CTR 2 OUT 65 D GND 31 PFI 27/P0.27/CTR 3 SOURCE 64 PFI 26/P0.26/CTR 3 GATE 30 D GND 63 PFI 25/P0.25/CTR 3 AUX 29 PFI 24/P0.24/CTR 3 OUT 62 D GND 28 PFI 23/P0.23/CTR 4 SOURCE 61 PFI 22/P0.22/CTR 4 GATE 27 D GND 60 PFI 21/P0.21/CTR 4 AUX 26 PFI 20/P0.20/CTR 4 OUT DIO/CTR 59 D GND 25 PFI 19/P0.19/CTR 5 SOURCE 58 PFI 18/P0.18/CTR 5 GATE 24 D GND 57 PFI 17/P0.17/CTR 5 AUX 23 PFI 16/P0.16/CTR 5 OUT 56 R GND 22 PFI 15/P0.15/CTR 6 SOURCE 55 D GND 21 PFI 14/P0.14/CTR 6 GATE 54 PFI 13/P0.13/CTR 6 AUX 20 D GND 53 PFI 12/PO.12/CTR 6 OUT 19 R GND 52 PFI 11/P0.11/CTR 7 SOURCE 18 D GND DIO/CTR 51 PFI 10/PO.10/CTR 7 GATE 17 PFI 9/P0.9/CTR 7 AUX 50 D GND 16 PFI 8/P0.8/CTR 7 OUT 49 D GND 15 PFI 7/P0.7 48 PFI 6/P0.6 14 D GND 47 PFI 5/P0.5 13 PFI 4/P0.4 46 D GND 12 PFI 3/P0.3 45 PFI 2/P0.2 11 D GND 44 PFI 1/P0.1 10 PFI 0/P0.0 DIO/CTR 1 +5 V 35 R GND 2 PFI 39/CTR 0 SOURCE 36 D GND 3 PFI 38/CTR 0 GATE 37 RESERVED 4 RESERVED 38 RESERVED 5 PFI 36/CTR 0 OUT 39 D GND 6 PFI 33/CTR 1 AUX 40 PFI 37/CTR 0 AUX 7 PFI 35/CTR 1 SOURCE 41 D GND 8 PFI 34/CTR 1 GATE 42 D GND 9 PFI 32/CTR 1 OUT 43 R GND SCB-68A Quick Reference Label NI 660x Counter/Timer (TIO) Models R GND: These terminals are routed to RESERVED when using the product with a SH68-68-D1 shielded cable or routed to D GND when using the product with a R68-68 ribbon cable. Direct Feedthrough 1 S1 S2 2 123 2 | ni.com | NI 66xx Pinout Labels for the SCB-68A Note To Users Use the following label if you are connecting the SCB-68A to NI 6612 and NI 6614 models. Figure 2. NI 661x DIO/CTR 68 D GND 34 PFI 31/P0.31/CTR 2 SOURCE 67 PFI 30/P0.30/CTR 2 GATE 33 D GND 66 PFI 29/P0.29/CTR 2 AUX 32 PFI 28/P0.28/CTR 2 OUT 65 D GND 31 PFI 27/P0.27/CTR 3 SOURCE 64 PFI 26/P0.26/CTR 3 GATE 30 D GND 63 PFI 25/P0.25/CTR 3 AUX 29 PFI 24/P0.24/CTR 3 OUT 62 D GND 28 PFI 23/P0.23/CTR 4 SOURCE 61 PFI 22/P0.22/CTR 4 GATE 27 D GND 60 PFI 21/P0.21/CTR 4 AUX 26 PFI 20/P0.20/CTR 4 OUT DIO/CTR 59 D GND 25 PFI 19/P0.19/CTR 5 SOURCE 58 PFI 18/P0.18/CTR 5 GATE 24 D GND 57 PFI 17/P0.17/CTR 5 AUX 23 PFI 16/P0.16/CTR 5 OUT 56 R GND 22 PFI 15/P0.15/CTR 6 SOURCE 55 D GND 21 PFI 14/P0.14/CTR 6 GATE 54 PFI 13/P0.13/CTR 6 AUX 20 D GND 53 PFI 12/PO.12/CTR 6 OUT 19 R GND 52 PFI 11/P0.11/CTR 7 SOURCE 18 D GND DIO/CTR 51 PFI 10/PO.10/CTR 7 GATE 17 PFI 9/P0.9/CTR 7 AUX 50 D GND 16 PFI 8/P0.8/CTR 7 OUT 49 D GND 15 PFI 7/P0.7 48 PFI 6/P0.6 14 D GND 47 PFI 5/P0.5 13 PFI 4/P0.4 46 D GND 12 PFI 3/P0.3 45 PFI 2/P0.2 11 D GND 44 PFI 1/P0.1 10 PFI 0/P0.0 DIO/CTR 1 +5 V 35 R GND 2 PFI 39/P1.7/CTR 0 SOURCE 36 D GND 3 PFI 38/P1.6/CTR 0 GATE 37 RESERVED 4 RESERVED 38 RESERVED 5 PFI 36/P1.4/CTR 0 OUT 39 D GND 6 PFI 33/P1.1/CTR 1 AUX 40 PFI 37/P1.6/CTR 0 AUX 7 PFI 35/P1.3/CTR 1 SOURCE 41 D GND 8 PFI 34/P1.2/CTR 1 GATE 42 D GND 9 PFI 32/P1.0/CTR 1 OUT 43 R GND SCB-68A Quick Reference Label NI 661x Counter/Timer (TIO) Models R GND: These terminals are routed to RESERVED when using the product with a SH68-68-D1 shielded cable or routed to D GND when using the product with a R68-68 ribbon cable. Direct Feedthrough 1 S1 S2 2 123 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2017 National Instruments. All rights reserved. 376819A-01 Aug17
![]() |
NI 62xx/63xx Pinout Labels for SCB-68A Provides pinout labels for National Instruments (NI) 62xx and 63xx series multifunction I/O modules and devices when used with the SCB-68A shielded connector block, detailing connections for various connectors and configurations. |
![]() |
NI High-Speed Digitizers Getting Started Guide A guide to installing, configuring, and testing NI high-speed digitizers and accessories, including programming with NI-SCOPE software. Covers models NI 5105, 5114, 5122, 5124, 5132, 5133, 5142, 5152, 5153, 5154, 5160, 5162, 5185, 5186, 5620, 5621, 5622, 5900, and 5922. |
![]() |
NI Calibration Executive: Automated Calibration Software for Measurement Hardware National Instruments Calibration Executive software automates the verification and adjustment of NI measurement hardware. This document outlines supported products, system requirements, and additional resources for using the software. |
![]() |
National Instruments RF Signal Generators and Power Meters Overview A comprehensive overview of National Instruments' RF and microwave signal generators (NI PXI-5671, NI PXIe-5672, NI PXIe-5673, NI PXI-565x series) and RF power meter (NI USB-5680), detailing their key specifications, modulation capabilities, hardware architecture, software compatibility, and ordering information for various RF test and measurement applications. |
![]() |
NI-9218 Getting Started Guide - National Instruments A comprehensive guide for the National Instruments NI-9218 module, covering connector types, pinouts, supported measurement types (±16 V, ±65 mV, Full-Bridge, IEPE, ±20 mA, ±60 V, Half-Bridge, Quarter-Bridge), signal conditioning, TEDS support, and filtering. |
![]() |
National Instruments C Series Analog Input Modules: NI 9201, NI 921x, NI 9221, NI 923x Overview of National Instruments C Series analog input modules, including NI 9201, NI 921x, NI 9221, and NI 923x. Details features, specifications, system compatibility, and accessories for high-accuracy measurements in CompactRIO and CompactDAQ systems. |
![]() |
CompactRIO 和 LabVIEW 入门指南:嵌入式系统开发 本指南由 National Instruments 提供,介绍如何使用 LabVIEW 和 CompactRIO 开发嵌入式系统。涵盖硬件/软件设置、扫描接口、FPGA 接口和 VI 创建,适用于工业自动化。 |
![]() |
National Instruments NI-DAQmx and DAQ Device Installation Guide with Apex Waves Services Installation guide for National Instruments NI-DAQmx software and DAQ devices (PCI, PXI). Includes Apex Waves' services for NI hardware repair, calibration, and surplus. |