LOCKMASTERS logoPulse Pro
ការដំឡើងមូលដ្ឋាន
សៀវភៅណែនាំរបស់ម្ចាស់

Pulse Pro Basic Setup

Lock in factory mode (unlocks when “1” is pressed)

1. Set lock configuration and date format: *Lock bolt must remain in the retracted position throughout the configuration setup procedure*

  • Determine configuration # from the list below (Fig 1A) or refer to the configuration chart in the full instructions for all options
  • Retract the lock bolt
  • Press & hold “8” until lock double signals & red LED remains on
  • Enter configuration ID
  • Reenter configuration ID
  • Enter date format (0=Day/Month/Year, 1=Month/Day/Year)
  • LED flashes, keypad emits 2 beeps, LED goes out
  • Lock will now be in operating mode, preset Manager & Master codes are active
  • Manager: 60-123456 (Opens lock)
  • Master: 80-123456 (Does NOT open lock)
  • *If a dual custody configuration was set, a user must be activated before the lock can be opened*

Fig. 1A – Common configuration IDs:

  • 12: 10 users, single custody, manager management
  • 17: 50 users, single custody, manager management
  • 13: 10 users, dual custody, manager management, 1 TD override user (10)
  • 18: 50 users, dual custody, manager management, 10 TD override users (50 – 59)

2A. Activate Users: (Single Custody Mode)

  • Press & hold “1” until the lock double signals & the red LED remains on
  • Enter manager code, including position (60)
  • Enter user position to be added (2 digits)
  • Enter new user code
  • Reenter the new user code

2B. Activate Users: (Dual Custody Mode)

  • Press & hold “1” until the lock double signals & the red LED remains on
  • Enter manager code, including position (60)
  • Enter Master code, including position (80)
    • Any user code can be used in place of the master code once activated
  • Enter user position to be added (2 digits)
  • Enter new user code
  • Reenter the new user code

3. Set Time Delay: (Optional)

  • Press & hold “9” until lock double signals & red LED remains on
  • Enter manager code, including position (60)
  • Enter time delay (XX) followed by open window(XX)
  • Reenter time delay (XX) followed by open window(XX)

កំណត់ចំណាំ៖

  • Push / Pull-rated motorized deadbolts are set to manual extension by default
    • Press the “P” button to extend the bolt
  • Manager & Master codes are changed using the “Change User Code” instructions below
  • Detailed instructions, including all available configuration options, may be found in the full version of “Pulse Pro User Instructions” (QR link below)

LOCKMASTERS Pulse Pro Basic Setup - QR Codehttps://www.tecnosicurezza.it/admin/workspace/doc-ing/iu_pulsepro_12_eng.pdf

Changing User Code
*It is strongly recommended that code changes be performed with the door open*

  1. Press & hold “0” until lock double signals & red LED remains on
  2. Enter user position to be changed (1st 2 digits)
  3. Enter existing user code (6 digits)
  4. Enter new user code (6 digits)
  5. Reenter new user code (6 digits)

*Test new code at least 3X before closing door*

សម្រាប់ជំនួយបន្ថែម សូមទូរស័ព្ទមក ៨៦៦-៤៤៧-២១៩៤LOCKMASTERS logo

ឯកសារ/ធនធាន

LOCKMASTERS Pulse Pro Basic Setup [pdf] សៀវភៅណែនាំរបស់ម្ចាស់
PULSEPRO-SETUP-INST, Pulse Pro Basic Setup, Pro Basic Setup, Basic Setup

ឯកសារយោង

ទុកមតិយោបល់

អាសយដ្ឋានអ៊ីមែលរបស់អ្នកនឹងមិនត្រូវបានផ្សព្វផ្សាយទេ។ វាលដែលត្រូវការត្រូវបានសម្គាល់ *