Lock in factory mode (unlocks when “1” is pressed)
1. Set lock configuration and date format: *Lock bolt must remain in the retracted position throughout the configuration setup procedure*
- Determine configuration # from the list below (Fig 1A) or refer to the configuration chart in the full instructions for all options
- Retract the lock bolt
- Press & hold “8” until lock double signals & red LED remains on
- Enter configuration ID
- Reenter configuration ID
- Enter date format (0=Day/Month/Year, 1=Month/Day/Year)
- LED flashes, keypad emits 2 beeps, LED goes out
- Lock will now be in operating mode, preset Manager & Master codes are active
- Manager: 60-123456 (Opens lock)
- Master: 80-123456 (Does NOT open lock)
- *If a dual custody configuration was set, a user must be activated before the lock can be opened*
Fig. 1A – Common configuration IDs:
- 12: 10 users, single custody, manager management
- 17: 50 users, single custody, manager management
- 13: 10 users, dual custody, manager management, 1 TD override user (10)
- 18: 50 users, dual custody, manager management, 10 TD override users (50 – 59)
2A. Activate Users: (Single Custody Mode)
- Press & hold “1” until the lock double signals & the red LED remains on
- Enter manager code, including position (60)
- Enter user position to be added (2 digits)
- Enter new user code
- Reenter the new user code
2B. Activate Users: (Dual Custody Mode)
- Press & hold “1” until the lock double signals & the red LED remains on
- Enter manager code, including position (60)
- Enter Master code, including position (80)
- Any user code can be used in place of the master code once activated
- Enter user position to be added (2 digits)
- Enter new user code
- Reenter the new user code
3. Set Time Delay: (Optional)
- Press & hold “9” until lock double signals & red LED remains on
- Enter manager code, including position (60)
- Enter time delay (XX) followed by open window(XX)
- Reenter time delay (XX) followed by open window(XX)
កំណត់ចំណាំ៖
- Push / Pull-rated motorized deadbolts are set to manual extension by default
- Press the “P” button to extend the bolt
- Manager & Master codes are changed using the “Change User Code” instructions below
- Detailed instructions, including all available configuration options, may be found in the full version of “Pulse Pro User Instructions” (QR link below)
https://www.tecnosicurezza.it/admin/workspace/doc-ing/iu_pulsepro_12_eng.pdf
Changing User Code
*It is strongly recommended that code changes be performed with the door open*
- Press & hold “0” until lock double signals & red LED remains on
- Enter user position to be changed (1st 2 digits)
- Enter existing user code (6 digits)
- Enter new user code (6 digits)
- Reenter new user code (6 digits)
*Test new code at least 3X before closing door*
សម្រាប់ជំនួយបន្ថែម សូមទូរស័ព្ទមក ៨៦៦-៤៤៧-២១៩៤