KEISER-LOGO

KEISER A400 Bottom Power Console

KEISER-A400-Bottom-Power-Console-PRODUCT

លក្ខណៈបច្ចេកទេស

  • Power Console Size and Weight:
    • វិមាត្រ៖ ១២,២៥ ក្នុង .x ១៤,៤៥ ក្នុង។ x ១០ អ៊ិន្ឈ៍ (៣១១ ម។ ម។ ៣៦៧ ម។ ម។ x ២៥៤ ម។ ម) ។
    • ទម្ងន់៖ 157 ផោន (72 គីឡូក្រាម)
  • ស្នាមជើង៖ ៣.៧៥ ក្នុង .x ៣.៥ អ៊ីញ (៩.៥ ម។ ម។ x ៩ ម។ ម)
  • ម៉ាស៊ីនបង្ហាប់លើសview:
    • ម៉ូទ័រ៖ ១/២ HP
    • សមត្ថភាពធុងខ្យល់៖ 2.5 gallons (9.5 L) total
    • Machine Capacity: Up to 8 KEISER machines
    • Air Line: 3/8 in. x 6 ft. (1.83 m) tubing with 3/8 in. fittings
    • ប្រភេទប្រេងរំអិល៖ ប្រេងតិច
  • អគ្គិសនី៖
    • វ៉ុលtage: 100-240 វ៉ ~
    • បច្ចុប្បន្ន៖ ០-១.១២ ក
    • ប្រេកង់៖ 50-60 ហឺត

ការណែនាំអំពីការប្រើប្រាស់ផលិតផល

ការដំឡើង

  • Refer to the PART LIST for components included. Ensure proper placement of the Bottom Power Console.

ការតភ្ជាប់បណ្តាញផ្លូវអាកាស

  • Use the provided 3/8 Air Fitting Union to connect the air line to the track/delivery system. Do not modify the air line to 1/4 as it may affect performance.

ការតភ្ជាប់អគ្គិសនី

  • Connect the Power Entry Cords to the appropriate outlets as per the system overview.

ការភ្ជាប់អ៊ីនធឺណិត

  • Note that a CAT5e cable for an internet connection is not included.
  • A wired internet connection is required for firmware updates and diagnostics.

បញ្ជីផ្នែក

  1. Bottom Power Console
    • A. Compressor with 3/8” Air Line
    • B. Hub Server with SSD Local Storage
    • C. Power Supply (PoE)
    • D. ចំណុចចូលប្រើឥតខ្សែ
    • Includes two (2) CAT5e Ethernet Cables (Hub + Access Point to Power Supply)
  2. Two (2) Power Entry Cords: One (1) for the Electronics, one (1) for the Compressor
    • Included but not shown: 3/8” Air Fitting Union (to connect air line to track/delivery system) and 3/8” Compression Nut with Plug (use when bypassing the 3/8” outlet).
    • ចំណាំ៖ CAT5e cable for internet connection is not included. See ASSEMBLY AND INSTALLATION for system overview.KEISER-A400-Bottom-Power-Console-FIG-1

ភាពជាក់លាក់

Power Console Size and Weight

  • L x W x H៖ Bottom Power Console
    • 37 អ៊ិន្ឈ៍ x 17.5 អ៊ិន្ឈ៍ x 22 អ៊ិន្ឈ៍។
    • (៣៥៧ ម។ ម។ ៣៧០ ម។ ម។ ៩១ ម។ ម។ )
  • ទម្ងន់៖ Bottom Power Console 157 lbs (72 kgs)
  • ស្នាមជើង៖ ៣.៧៥ ក្នុង .x ៣.៥ អ៊ីញ (៩.៥ ម។ ម។ x ៩ ម។ ម)

ម៉ាស៊ីនបង្ហាប់លើសview

  • ម៉ូទ័រ៖ ១/២ HP
  • សមត្ថភាពធុងខ្យល់៖ 2.5 gallons (9.5 L) total
  • Machine Capacity: Up to 8 KEISER machines
  • Pressurized Air Delivery: 100 – 120 psig (6.89 – 8.27 bar)
  • Air Line: 3/8 in. x 6 ft. (1.83 m) tubing, with 3/8 in. fittings
  • រន្ធខ្យល់៖ ខាងឆ្វេង​ដៃ
    • 3/8” Compression Fitting (qty 1)
    • 1/4” Quick-disconnect (qty 2)
  • ផ្នែក​ខាង​ស្តាំ​ដៃ
    • 1/4” Quick-disconnect (qty 3)
  • ប្រភេទប្រេងរំអិល៖ Oil-less (requires no lubrication)
  • Decibel rating: 61 - 63 dB
  • Under normal operating conditions, the distance of 39.37 inches (1 m)

អគ្គិសនី

  • Power Supply (PoE) Hub, and Access Point
  • វ៉ុលtage: 100-240 វ៉ ~
  • បច្ចុប្បន្ន៖ ០-១.១២ ក
  • ប្រេកង់៖ 50-60 ហឺត

ម៉ាស៊ីនបង្ហាប់

  • Confirm the compressor model for the operating voltage
  • វ៉ុលtage: 115/230 V ~
  • បច្ចុប្បន្ន៖ ២០០/៥ ក
  • ប្រេកង់៖ 50/60 ហឺត

ការណែនាំ

  • Reference the marking plate on unit for serial number and specific product information.
  • Please refer to the manufacturer’s user manuals for detailed product and safety information regarding the electronic devices.
  • សំខាន់៖ DO NOT CONNECT OR REDUCE THE POWER CONSOLE 3/8” AIR LINE TO A 1/4” AIR LINE SYSTEM. The A400 System is designed for 3/8” air lines only.
  • Any modifications/reductions may cause performance issues, including slow resistance increase.
  • Air Direct-Connect Note: Machines may connect directly to the 1/4” outlets on the compressor, using the 1/4” quick-disconnect with 8 mm tubing (supplied with the machines, 7 ft / 2.13 m in length), in place of the 3/8” air supply line.
  • This is a direct connection, not part of a 1/4” air line system. Installation of a 3/8” compression nut with plug is required. Supports up to five machines.KEISER-A400-Bottom-Power-Console-FIG-2 KEISER-A400-Bottom-Power-Console-FIG-3

INTERNAL CONNECTIONS DIAGRAM

  • Internal air and power connection points shown for service reference.
  • Power cords are labeled inside the console and highlighted here for visibility.
    1. ម៉ាស៊ីន​បញ្ចូល​ខ្យល់
    2. ការផ្គត់ផ្គង់ថាមពល
    3. Secondary Air Compressor (for Top Power Console configurations)
    4. AC/DC Converter-to-HubKEISER-A400-Bottom-Power-Console-FIG-4
  • See the SYSTEM POWER section for the Safe Shutdown procedure.

តម្រូវការថាមពល

  • កម្មវិធី៖ All Bottom and Power Console configurations
  • សៀគ្វីពិសេស៖ Plug the compressor and electronics into a NEMA 6-20R duplex outlet/receptacle on a separate, dedicated, and grounded 230V branch circuit protected by a 20-amp circuit breaker. Do not share this circuit with other devices.
  • ការផ្គត់ផ្គង់ថាមពលមានស្ថេរភាព៖ Ensure the power supply is stable, reliable, and meets the necessary specifications (230V, 20A) to support all the devices in the console(s).
  • ការតភ្ជាប់ផ្ទាល់៖ Avoid using extension cords or power strips; connect directly to the dedicated outlet.
  • ថាមពលបម្រុងទុក៖ Consider implementing backup power options (e.g., UPS) at the console’s electrical power entry point to ensure uninterrupted operation and prevent loss of data collection from machines during power outages.
  • ពិគ្រោះជាមួយជាងអគ្គិសនី៖ If you’re unsure about the dedicated branch circuit specification or have questions about the electrical requirements, consult a licensed electrician.KEISER-A400-Bottom-Power-Console-FIG-5

INTERNET and Wi-Fi

Internet – General Information

  • The Hub Server requires a wired Internet connection for firmware updates and remote diagnostics/servicing. If Internet access is restricted, consult the facility’s IT or Network Administrator before equipment delivery.
  • ល្បឿន៖ A minimum of 20 Mbps download and 5 Mbps upload is recommended to support data transfer, firmware updates, and remote support.

Connecting the Hub Server to the Internet

    1. Plug the provided CAT5e Ethernet cable into the Ethernet port farthest from the power inlet on the Hub Server.
    2. Connect the other end to the facility’s router or network switch.
  • DHCP is pre-configured on the Hub Server’s Internet port. Therefore, the network must have a DHCP server to assign IP addresses automatically.
  • The static network interface for internal communication is set to 192168150.2.
  • Domain List: The following domains must be accessible for updates and diagnostics: *.keiser.com, *.docker.com, *.docker.io, *.sentry.io, ៩, ntp.ubuntu.com
  • ចំណាំ៖ Static IPs and port configurations are not required.

CAT5e Cable Specifications

  • ល្បឿនផ្ទេរទិន្នន័យ៖ Up to 1 Gbps (Gigabit Ethernet) at a distance of up to 100 meters (328 feet). This is also the PoE limitation for power and data delivery.
  • កម្រិតបញ្ជូន៖ Supports a frequency of 100 MHz (limit for data transmission).
  • សំខាន់៖ Use CAT5e (enhanced) cabling, not CAT5, to maintain system design specifications.
  • Improved Cross-talk Reduction: Better protection against signal interference.
  • Higher Data Speeds: CAT5e supports Gigabit Ethernet, while CAT5 is limited to 100 Mbps.

Access Point – General Information

  • The Access Point allows centralized control of all A400 Series exercise machines on the network using the Keiser Manager app. The maximum range is 160 feet (49 meters).

ការភ្ជាប់ចំណុចចូលដំណើរការ

  • Plug the provided CAT5e Ethernet cable from the Access Point Ethernet port into the Power Supply (Netgear Switch) of the A400 Bottom Power Console.
  • The Access Point does not need a power cord, as it is powered by PoE through the CAT5e cable.

Access Point Specifications

  • ប្រេកង់៖ 2.4 GHz
  • ស្តង់ដារ៖ 802.11b/g/n
  • ជំនាន់ Wi-Fi៖ វ៉ាយហ្វាយ ៦
  • ចំណាំ៖ To extend the range, additional Access Points can be added wirelessly. For instance, place one in the training room and another in an adjacent office.
  • For instructions, safety precautions, and detailed specifications, refer to the manufacturer’s User Manual included with the device.

ការប្រមូលផ្តុំនិងការដំឡើង

  • Assembly and installation must be performed by qualified technicians with the necessary knowledge, tools, and equipment. These procedures are not for DIY installation.

ប្រព័ន្ធបញ្ចប់view

  • The Bottom Power Console supplies air and power for up to eight KEISER A400 machines.

វារួមបញ្ចូលៈ

  • A. ម៉ាស៊ីនបង្ហាប់
  • B. Hub Server with SSD Local Storage
  • C. Power Supply (PoE)
  • D. ចំណុចចូលប្រើឥតខ្សែKEISER-A400-Bottom-Power-Console-FIG-6

ប្រតិបត្តិការ

  • The KEISER Manager App connects to the Bottom Power Console through the Access Point, offering centralized control of all A400 machines on the network.

លក្ខណៈសំខាន់ៗរួមមានៈ

  • Configuring and monitoring all Keiser A400 machines.
  • Setting up and managing user profiles.
  • Admin account set up required. See the ACCOUNT SET UP section on page 7 for more details.

ទីតាំងនិងទីតាំង

  • Locate the unit in a clean, dry, and well-ventilated area.
  • ដាក់ឯកតាលើផ្ទៃរាបស្មើ។
  • Ensure adequate air flow around the unit.
  • Ensure a minimum of 12 in. (305 mm) of clear space around the unit.
  • Use an electrical circuit with the appropriate power rating; avoid the use of an extension cord.
  • Do not store/stack any items on top of, or leaning on, the unit.

ឧបករណ៍ដែលត្រូវការ

  • ឧបករណ៍កាត់បំពង់
  • Wrench លៃតម្រូវបាន។
  • 5/8" Wrench បើកចុង
  • Probe Tool (1/8” Hex Key) If servicing (safe shut down) is required

នីតិវិធីនៃការជួបប្រជុំគ្នា។

  • The A400 Bottom Power Console arrives fully assembled. Use this diagram to confirm connections.
  • សំខាន់៖ Follow the sequence on the SYSTEMIZATION page before applying power.KEISER-A400-Bottom-Power-Console-FIG-7

ចំណាំ៖

  • CAT5e Ethernet Cable Color: While blue is common for CAT5e cables, Keiser supplies black CAT5e cables, which function identically.
  • ការតភ្ជាប់ការផ្គត់ផ្គង់ថាមពល៖ Suggested machine-to-power supply connections are shown, but any 30W or 60W port on the power supply can be used.

SYSTEMIZATION

  • Once assembly is complete, the Bottom Power Console is ready for system installation.
  • ចំណាំ៖ Track/delivery system sold and installed separately.

នីតិវិធី៖

  1. Connect the air supply to the track/delivery system.
    • Use a 3/8” Union Fitting to connect the 3/8” Air Line from the Power Console to the Air Supply Line at the track/delivery system.
  2. Connect the CAT5e cables from the track/delivery system to the Power Supply.
    • Surface-mounted outlets (typical, as shown) or direct to A400 network-connected wall/floor outlets.
  3. Connect the Hub to the Internet using a CAT5e Cable.
  4. Connect the Machines to the track/delivery outlet.
    1. Air Line Quick-disconnect (QD) and PoE Cable.
  5. Power on the Power Console by connecting the two Power Entry Cords (Compressor and Electronics) into a separate, dedicated, and grounded branch power circuit (NEMA 6-20R duplex outlet).KEISER-A400-Bottom-Power-Console-FIG-8

ថាមពលប្រព័ន្ធ៖

Once the Power Console is powered ON, the Hub automatically powers and cycles ON (Red and Blue lights illuminated).KEISER-A400-Bottom-Power-Console-FIG-9

  • ប្រតិបត្តិការសេវាកម្ម – Use the Hub Safe Shutdown whenever the console needs to be powered down (e.g., for service or relocation). Tool required: Probe Tool (1/8” Hex Key).

Ensure connected exercise machines are not in use:

  • Safe Shut Down: Press the Power Button. After ~15 seconds, the Blue light turns off; the Red light remains on (Hub powered but not cycled).
  • Restart / Manual Cycle: Once power is restored, the Hub Red and Blue lights turn ON. If no Blue light is visible, press. Press the Power Button to cycle on the Hub.

ចំណាំជូនអតិថិជន៖

  • Continue to account ACCOUNT SET UP on the following page.KEISER-A400-Bottom-Power-Console-FIG-10

ACCOUNT SET UP KEISER MANAGER APP

After system installation, the end user can now:

  1. Download the Keiser Manager app.KEISER-A400-Bottom-Power-Console-FIG-11
  2. Continue Admin account set up using the Keiser Manager app quick start guide.

Admin Account Notes

The Keiser Manager app enables Admins to.

  • Configure and monitor all Keiser A400 machines on the network.
  • Set up and manage user profiles.

Before use, check for system updates within the app:

  • On the main Live page, tap “Facility” in the bottom navigation bar.
  • Tap “Check for Hub updates.”
  • Tap “Check for Display updates.”
  • ចំណាំ៖ Update times vary and depend on Internet speed.KEISER-A400-Bottom-Power-Console-FIG-12

ចំណាំដល់អតិថិជន

ស្កេន QR កូដ

សំណួរគេសួរញឹកញាប់

Can I use a CAT6 cable for the internet connection?

It is recommended to use a CAT5e cable for an internet connection as specified in the manual for optimal performance.

How many machines can the compressor support?

The compressor can support up to 8 KEISER machines.

ឯកសារ/ធនធាន

KEISER A400 Bottom Power Console [pdf] ការណែនាំអំពីការដំឡើង
A400 Bottom Power Console, A400, Bottom Power Console, Power Console, Console

ឯកសារយោង

ទុកមតិយោបល់

អាសយដ្ឋានអ៊ីមែលរបស់អ្នកនឹងមិនត្រូវបានផ្សព្វផ្សាយទេ។ វាលដែលត្រូវការត្រូវបានសម្គាល់ *