JBC TCP Thermocouple Pointer

ការណែនាំអំពីការប្រើប្រាស់ផលិតផល
សៀវភៅណែនាំនេះត្រូវនឹងឯកសារយោងដូចខាងក្រោម៖
TCP-A
បញ្ជីវេចខ្ចប់
ធាតុខាងក្រោមត្រូវបានរួមបញ្ចូល:
លក្ខណៈពិសេស
TCP Thermocouple Pointer is designed to monitor the surface temperature of the PCB or its components with high precision positioning. It works on any type of material and can measure temperatures up t300 °C / 572 °F with an accuracy of ±10 °C / 19 °F. Its design allows for quick and accurate placement of high-density printed circuit boards, reducing setup time, even at high temperatures.TCP features a K-type signal output, so the monitoring device to which it is connected must have a K-type compatible connector. For compatibility information with JBC devices, visit the product’s page at www.jbctools.com. For more information on compatibility with external devices, contact JBC Technical Support. The sensor is completely isolated (electrically) from the external parts of the product. TCP is ESD safe with no extra connections, as long as it sits on any kind of ESD safe surface, e.g., JBC ESD safe table mats, a ground-wired metal surface, etc. It is also possible to ground the product from any of its metal surfaces.
TCP is not intended for use in fluids such as flux or molten tin, nor is it designed for the measurement of hot air. When connecting TCP to a monitoring device (K-type compatible connector required), always use the thermocouple extension cable supplied with this product. The temperature measurement can be affected by air currents. Keep this in mind when using hot air tools (JTT or NH) or fume extractors (FAE1, FAE2)
កន្លែងធ្វើការ Example
របៀបប្រើ
- សូមពិនិត្យមើលថាឧបករណ៍ចាប់សញ្ញាមានពែង និងផ្នែកមួយនៃបន្ទះចរន្តអគ្គិសនីភ្ជាប់ទៅនឹងចុងឧបករណ៍ចាប់សញ្ញា។ ប្រសិនបើវារលុង សូមមើលផ្នែកបន្ទាប់ ការជំនួសបន្ទះចរន្តអគ្គិសនី។
- Connect the thermocouple pointer to a monitoring device (K-type compatible connector required) using the supplied thermocouple extension cable.
- Thanks to its magnetic base, TCP can be placed and stabilized onto magnetic surfaces. If there is no magnetic surface available, see the “Anchor Assembly” section.
- ជៀសវាងការដាក់មូលដ្ឋាននៃ TCP ឱ្យប៉ះដោយផ្ទាល់ជាមួយប្រភពកំដៅ។
- យកទ្រនិចចេញពីគល់របស់វា ហើយដាក់វាបញ្ឈរទាំងស្រុងនៅលើចំណុចពិតប្រាកដដែលអ្នកចង់វាស់។
- Important: Press the pointer lightly against the measurement spot to ensure that theconductive pad makes contact around the entire perimeter.

ការជំនួសបន្ទះចរន្តអគ្គិសនី
- កាន់ពែងដែលបានផ្គុំរួចដោយដៃម្ខាង ហើយយកសំណល់នៃបន្ទះចរន្តចេញដោយរំកិលទ្រនិចនៅខាងក្នុងវាថ្នមៗ។ បន្ទាប់មក ផ្ដាច់ពែងចេញពីឧបករណ៍ចាប់សញ្ញា។ បើចាំបាច់ សូមជំនួសពែងដោយពែងថ្មី។
- Unwrap both sides of the conductive pad. Place it on a flat surface and place the cup ontop of the conductive pad.

- បន្ទាប់មក ចុចសម្ពាធចុះក្រោមដើម្បីកាត់ផ្នែកមួយនៃបន្ទះចរន្តអគ្គិសនី ដែលនៅតែជាប់ក្នុងពែងចេញ។

- . Insert the sensor through the top opening of the cup until it reaches the pad. Lightly press down the sensor a couple of times so that it is inserted into the pad, but without piercing it completely
- សំខាន់៖ Do not pierce the conductive pad completely. Leave a thin layer of conductive material between the tip of the sensor and the bottom surface of the pad.

- សំខាន់៖ Do not pierce the conductive pad completely. Leave a thin layer of conductive material between the tip of the sensor and the bottom surface of the pad.
- លើកឧបករណ៍ចាប់សញ្ញាដោយប្រុងប្រយ័ត្នជាមួយនឹងពែង និងបន្ទះដែលបង្កប់នៅខាងក្នុង។

ការផ្គុំយុថ្កា
If there is no magnetic surface available to place the base onto, the supplied anchor (magnetic) can be placed on a JBC support, allowing TCP to be fixed onto it. After its use, the base can be more easilyseparated from the anchor/magnetic surface by tilting it apart.
ដើម្បីដំឡើងយុថ្កាម៉ាញេទិកទៅលើមគ្គុទ្ទេសក៍នៃទ្រ៖
- ដោះយុថ្កាចេញដោយប្រើសោ Allen ទំហំ 2.5 (DIN911)។
- សមនឹង clamp នៃយុថ្កាចូលទៅក្នុងមគ្គុទ្ទេសក៍មួយនៅលើទ្រពីខាងក្រោម (1)។
- ដាក់ឌីសនៅលើមគ្គុទ្ទេសក៍ ដោយតម្រឹមកណ្តាលរបស់វាជាមួយនឹងកណ្តាលនៃផ្នែកខាងក្រោម។
- ជួសជុលយុថ្កាដោយវីសបំណែកទាំងពីរចូលគ្នាពីខាងលើ (2)។
- ដាក់បាតនៃទ្រនិចទែម៉ូកូបនៅលើយុថ្កា។

ថែទាំ
- មុនពេលអនុវត្តការថែទាំ ឬកន្លែងស្តុកទុក តែងតែអនុញ្ញាតឱ្យឧបករណ៍ត្រជាក់ចុះ។
- ពិនិត្យជាទៀងទាត់ថាឧបករណ៍ចាប់សញ្ញាគឺស្អាត។
- ប្រើការផ្សាយពាណិជ្ជកម្មamp ក្រណាត់នៅពេលសម្អាត។ ជាតិអាល់កុលអាចប្រើសម្រាប់តែសម្អាតផ្នែកលោហៈប៉ុណ្ណោះ។
- ផ្លាស់ប្តូរផ្នែកដែលខូច ឬខូច។ ប្រើតែគ្រឿងបន្លាស់ JBC ដើមប៉ុណ្ណោះ។
- ការជួសជុលគួរតែត្រូវបានអនុវត្តដោយសេវាកម្មបច្ចេកទេសដែលមានការអនុញ្ញាតពី JBC ប៉ុណ្ណោះ។
លក្ខណៈបច្ចេកទេស
TCP
Thermocouple Pointer
Ref.: TCP-A
- លទ្ធផល៖ ប្រភេទ K
- ជួរសីតុណ្ហភាពដែលអាចវាស់វែងបាន៖ ២៥-៣០០ អង្សាសេ / ៧៧-៥៧២ អង្សាសេ
- ទំងន់សុទ្ធសរុប: 470 ក្រាម / 1.04 lb
- វិមាត្រ/ទំងន់កញ្ចប់៖ 280 x 280 x 164 mm / 730 g (L x W x H) 11.02 x 11.02 x 6.46 in / 1.61 lb
- អនុលោមតាមស្តង់ដារ CE ។
- ESD មានសុវត្ថិភាព។
ការធានា
ការធានារយៈពេល 2 ឆ្នាំរបស់ JBC គ្របដណ្តប់ឧបករណ៍នេះប្រឆាំងនឹងពិការភាពផលិតកម្មទាំងអស់ រួមទាំងការជំនួសគ្រឿងបន្លាស់ និងកម្លាំងពលកម្ម។ ការធានាមិនគ្របដណ្តប់លើការពាក់ ឬការប្រើប្រាស់ខុសផលិតផលឡើយ។ ដើម្បីឱ្យការធានាមានសុពលភាព ឧបករណ៍ត្រូវតែត្រលប់មកវិញtage បានបង់ប្រាក់ទៅឱ្យអ្នកចែកបៀដែលជាកន្លែងដែលវាត្រូវបានទិញ។
ផលិតផលនេះមិនគួរបោះចោលក្នុងសំរាមទេ។ ដោយអនុលោមតាមការណែនាំរបស់អ៊ឺរ៉ុប 2012/19/EU ឧបករណ៍អេឡិចត្រូនិកនៅចុងបញ្ចប់នៃជីវិតរបស់វាត្រូវតែប្រមូល ហើយត្រឡប់ទៅកន្លែងកែច្នៃឡើងវិញដែលមានការអនុញ្ញាត។
សំណួរគេសួរញឹកញាប់
Q: Can TCP be used in fluids?
A: No, TCP is not intended for use in fluids.
Q: How should I store TCP when not in use?
A: Store TCP on an ESD safe surface to maintain its integrity.
Q: Can TCP measure hot air?
A: TCP is not designed for the measurement of hot air.
ឯកសារ/ធនធាន
![]() |
JBC TCP Thermocouple Pointer [pdf] សៀវភៅណែនាំ TCP-A, TCP Thermocouple Pointer, TCP, Thermocouple Pointer, Pointer |