ឧបករណ៍បញ្ជាធាតុកំដៅឌីជីថល
លក្ខណៈបច្ចេកទេស
- Ingress protection: IPX4
- វ៉ុលtagអ៊ី: 230-245 VAC
- ទិន្នផលថាមពលអតិបរមា: 800W
- វិមាត្រ៖ ១១៣ x ៤៣ x ១៥ ម។
- Approvals: CE, tested to EN55014-1:2006
ការណែនាំអំពីការប្រើប្រាស់ផលិតផល
1. ការប្រុងប្រយ័ត្នសុវត្ថិភាព
Before installation, ensure compliance with IEE, Part P, and
local authority regulations. Isolate the mains electrical circuit
and fused spur unit before fitting. Do not install in IEE bathroom
តំបន់ 1 ។
2. សេចក្តីណែនាំអំពីខ្សែភ្លើង
Ensure a fused spur is included in the supply circuit to the
controller with the correct size fuse. Follow the wiring
instructions for electrical element wires (OUT) and main cable
wires (IN) as specified in the manual.
3. ការដំឡើង
Clamp the element cable to the bottom of the wall controller.
Carefully fit the control plate into the back box, ensuring no
wires are trapped. Secure the control plate using the provided
ជួសជុលវីស។
4. សេចក្តីណែនាំប្រតិបត្តិការ
The control plate features four buttons: ON/OFF, temperature
increase, temperature decrease, and ECO boost. Familiarize yourself
with the functions of each button for efficient operation.
5. ប្រតិបត្តិការមូលដ្ឋាន
Follow the user manual for basic operation instructions to
effectively control the electrical element wall controller.
6. មុខងារអេកូ
Understand and utilize the ECO function of the wall controller
for energy-efficient operation according to the provided
ការណែនាំ។
សំណួរគេសួរញឹកញាប់
Q: What should I do if the unit is not functioning properly
បន្ទាប់ពីការដំឡើង?
A: Check all connections as per the wiring instructions. Ensure
that the unit is properly earthed. If issues persist, contact
ការគាំទ្រអតិថិជនសម្រាប់ជំនួយ។
Q: Can this wall controller be used in a bathroom?
A: No, this unit should not be fitted in IEE bathroom Zone 1 for
ហេតុផលសុវត្ថិភាព។
ELECTRICAL ELEMENT WALL CONTROLLER
Please read the instructions thoroughly before attempting to tit the product or attach it to your electrical system.
Please ensure that you chose a suitably sized electrical element for your towel warmer.
Safety Precautions: This product should Defined by a competent person who can ensure compliance with IEE. Part P and local authority regulations. Ensure the mains electrical circuit and the fused spur unit are both isolated before fining. This unit should not he fitted in IEE bathroom Zone.1.
ការណែនាំអំពីខ្សែភ្លើង
A fused spur is required in the supply circuit to the controller. fitted with the correct size fuse.
The 2 x E & 2 x N terminals are linked on the printed circuit board.
ELECTRICAL ELEMENT WIRES (OUT)
៦៧ ៨
From Left to Right terminals 1-3 correspond to the Element cable
The element wires should be connected as follows:
Green/Yellow Earth to terminal 1 (N on board) Blue Neutral to terminal 2 (L on board) Brown Live to terminal 3 (L/T on board)
VERY IMPORTANT – This unit must be earthed
MAIN CABLE WIRES (IN)
៦៧ ៨
From Left to Right terminals 4-6 correspond to the Mains cable wires.
The mains cable wires should be connected as follows:
Brown Live to terminal 4 (L on board) Blue Neutral to terminal 5 (N on board) Green/Yellow Earth to terminal 6 (E on board)
VERY IMPORIANT – This unit must be earthed
Clamp the element cable to the bottom of the wall controller
Carefully fit the control plate into the back box ensuring that no wires are trapped during the sitting process. Use the two fixing screws to secure to the back box.
ការណែនាំអំពីប្រតិបត្តិការ
There are four buttons on the control plate. ON/OFF (1), temperature Increase (2), temperature decrease (3), ECO boost button (4).
ការអនុវត្តន៍មូលដ្ឋាន
The unit in standby has the main LED in RED. To turn on in normal mode, press the ON/OFF button and release it. The LED will turn BLUE, the ORANGE LED bank will light between one to five LED’s. To increase or decrease the temperature press the `increase/decrease’ buttons to attain the desired setting. Each one of the ORANGE LEDs represents the following power output from the element: 5 LEDs =100% power > 4 LEDs = 85% power > 3 LEDs = 70% power > 2 LEDs = 55% power >1 LED = 40% power To turn the unit OFF. press the ON/OFF button and release it. NB The control plate contains a memory and whatever the temperature that was set when the unit was turned OFF, will be the temperature (number of LED’s lit) that the element will resume at when the unit is turned ON the next time.
មុខងារអេកូ
Press the ECU button from either power on or from standard control. the power LED will turn GREEN. The ECO function allows you to go to a higher power setting for 30 minutes (To heat the towel warmer) this power level can be set in the first 30 minutes. After 30 minutes the power is reduced to the pre-set lower level for 90 minutes. The power output can be set using the increase/ decrease buttons to set your preferred rail temperature. After 2 Hours the controller will turn on. Both the 30 minute and the 90 minutes settings are saved in the controller. 5 LEDs = 100% power > 4 LEDs = 85% power > 3 LEDs = 70% power > 2 LEDs = 55% power >1 LED = 40% power
Technical Data. Ingress protection: IPX4 Voltage: 230-245 vac Maximum power output: 800w Dimensions: 85 x 85 x 20mm Approvals: CE, tested to EN55014-1:2006
ឯកសារ/ធនធាន
![]() |
DuraTherm Digital Heating Element Controller [pdf] សៀវភៅណែនាំ Digital Heating Element Controller, Heating Element Controller, Element Controller, Controller |