KEPLERX - Logo15SEER2 series
Multi-Position, Multi-speed
Air Handler 1½ to 5 Tons
KEPLERX K15HVC18W2H Multi Position Air Handler - Cover

Product Features

  • Internal factory-installed Piston as expansion valve for cooling and heat pump applications.
  • PSC & ECM motor through 1.5-5ton, provide selections of air flow to meet desired applications.
  • Painted Galvanized steel cabinet with thermal insulator cover all inside panels to reduce heat transfer and prevent condensed water accumulation.
  • “A” Shape coil, constructed with copper tubing and enhanced anti-corrosion aluminum fins.
  • Coil mounting track for quick repositioning.
  • Optimized for use with R-410A refrigerant.
  • Horizontal or vertical configuration capabilities.
  • 22”depth for easier attic access.
  • 3/4” NPT primary and secondary drains.
  • Foil-faced insulation covers the internal casing to reduce cabinet condensation.
  • Glue-less cabinet insulation retention.
  • Tool-less filter access.
  • Field Installed 5 kW – 20 kW electric heater kits available.
  • AHRI certified; ETL listed.

Nomenclature

KEPLERX K15HVC18W2H Multi Position Air Handler - Nomenclature

Product Specifications

K15HVC18W2H K15HVC24W2H K15HVC30W2H K15HVC36W2H K15HVC42W2H  K15HVC48W2H Kl5HVC60W2H
Nominal Ratings
Cooling (Btu/h) 17,500 22,000 28,000 33,000 40,000 45,000 55,500
Blower
Diameter 11 11 11 11 11 11
Width 11 11 11 11 11 11 11
Coil Connections
Liquid ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜”
Suction ¾” ¾” ¾” ¾” ¾” ⅞ “ ⅞ “
Coil Drain Connect (NPT) ¾” ¾” ¾” ¾” ¾” ¾” ¾”
Electrical Data
Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Minimum Circuit Ampacity 1.8A 2.3A 2.8A 4.0A 4.5A 5.2A 5.4A
Max. Overcurrent Device (Amos) 3.0A 3.0A 3.0A 6.0A 6.0A 6.0A 6.0A
Min/Max Volts 187/253 187/253 187/253 187/253 187/253 187/253 187/253
Blower Motor
Full Load Amps (FLA) 1.1A 1.7A 2.1A 2.8A 3.3A 3.6A 3.9A
Horsepower (HP) 1/4HP 2/7HP 1/2HP 1/2HP  3/4HP 3/4 HP  3/4HP
Ship Weight (Lbs.) 137 143 141 141 146 185 185

Dimensions

KEPLERX K15HVC18W2H Multi Position Air Handler - Dimensions

DEMENSIONAL DATA

MODEL SIZE Dimensions inch
UNIT HEIGHT
“H” IN
UNIT WIDTH
“W” IN.
UNIT LENGHT
“D” IN
SUPPLYDUCT
“A” IN
LIQUID LINE/
VAPOR LINE IN
K15HVC18W2H 45-3/4″ 19-5/8″ 22″ 17-7/8″ 3/8″ / 3/4″
K15HVC24W2H 45-3/4″ 19-5/8″ 22″ 17-7/8″ 3/8″ / 3/4″
K15HVC30W2H 45-3/4″ 19-5/8″ 22″ 17-7/8″ 3/8″ / 3/4″
K15HVC36W2H 45-3/4″ 19-5/8″ 22″ 17-7/8″ 3/8″ / 3/4″
K15HVC42W2H 45-3/4″ 19-5/8″ 22″ 17-7/8″ 3/8″ / 3/4″
K15HVC48W2H 53-1/8″ 22″ 24-1/2″ 19-1/2″ 3/8″ / 7/8″
K15HVC60W2H 53-1/8″ 22″ 24-1/2″ 19-1/2″ 3/8″ / 7/8″

WIRING DIAGRAM

  1. To avoid the electrical shock, please connect the air conditioner with the ground lug. The main power plug in the air conditioner has been joined with the ground wiring, please don’t change it freely.
  2. The power socket is used as the air conditioner specially.
  3. Don’t pull the power wiring hard.
  4. When connecting the air conditioner with the ground, observe the local codes.
  5. If necessary, use the power fuse or the circuit, breaker or the corresponding scale amper®:

KEPLERX K15HVC18W2H Multi Position Air Handler - Wiring Diagrams 1Wiring connection for A/C Systems

KEPLERX K15HVC18W2H Multi Position Air Handler - Wiring Diagrams 2Wiring connection for H/P Systems

Applicable for K15HVC18W2H, K15HVC24W2H

KEPLERX K15HVC18W2H Multi Position Air Handler - Wiring Diagrams 3

LINEAR ANNOTATION NOTES DIAL SWITCH DESCRIPTION
_____  FACTORY DEFAULT
– – – – – – FIELD INSTALLED
– – – – – – FACTORY OPTION
Please refer to the actual wiring diagram
1. Grounded and all wiring to conform to I.E.C.
2. Replacement wire must be the same gauge and insulation type as original wire.
3. The units should connect the stated-cross-section earth wire and keep it grounding unfailingly.
4. Electric Heater is optional.
SW1-1 AC FAN
The rest of the DIP switches are reserved

K15HVC30W2H, K15HVC36W2H, K15HVC42W2H, K15HVC48W2H, K15HVC60W2H
KEPLERX K15HVC18W2H Multi Position Air Handler - Wiring Diagrams 4

DIAL SWITCH DESCRIPTION
LINEAR ANNOTATION NOTES SW1-1 LOW
_____  FACTORY DEFAULT
– – – – – – FIELD INSTALLED
– – – – – – FACTORY OPTION
Please refer to the actual wiring diagram
1. Grounded and all wiring to conform to I.E.C.
2. Replacement wire must be the same gauge and insulation type as original wire.
3. The units should connect the stated-cross-section earth wire and keep it grounding unfailingly.
4. Electric Heater is optional.
SW1-2 MEDIUM LOW
SW1-3 MEDIUM
SW2-1 MEDIUM HIGH
SW2-2 HIGH
DIAL SWITCH FAN SPEED MODE MODEL DIAL SWITCH FAN SPEED MODE MODEL
KEPLERX K15HVC18W2H Multi Position Air Handler - icon 2 MEDIUM 30K, 42K KEPLERX K15HVC18W2H Multi Position Air Handler - icon 3 MEDIUM HIGH 36K, 48K, 60K

KEPLERX K15HVC18W2H Multi Position Air Handler - icon 1COMPANY WITH
QUALITY SYSTEM
CERTIFIED BY DNV GL
= ISO 9001=
COMPANY WITH
ENVIRONMENTAL SYSTEM
CERTIFIED BY DNV GL
= ISO 14001=

* Complete warranty details available from your local dealer or at www.eqkhvac.com. To receive the 10-Year Compressor and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec.

http://www.keplerx.net
15SEER2 series

Documents / Resources

KEPLERX K15HVC18W2H Multi Position Air Handler [pdf] Datasheet
K15HVC18W2H, K15HVC24W2H, K15HVC30W2H, K15HVC36W2H, K15HVC42W2H, K15HVC48W2H, K15HVC60W2H, K15HVC18W2H Multi Position Air Handler, K15HVC18W2H, Multi Position Air Handler, Position Air Handler, Air Handler, Handler