Introduction

Overview

  • KHS is a sinusoidal motor controller specifically equipped with photo-electric isolation to meet high-voltage (Up to 360V) requirements.
  • This manual introduces the features, installation, and maintenance of the Kelly sinusoidal brushless DC (BLDC) motor controller. Please read the manual carefully before using the controller. If you have any questions, contact the Kelly Controls support center.
  • Kelly programmable motor controllers provide efficient, smooth, and quiet control for electric motorcycles, golf carts, go-karts, and industrial motor control.
  • The primary design focus is to address noise issues in BLDC motor drive applications. The KHS motor controller must be used with Hall sensors and currently does not support sensor-less brushless motors.
  • Compared with the traditional trapezoidal control technology, this technology, based on sinusoidal drive technology, can reduce operating noise and switch loss by one-third, meeting the noise reduction and efficiency requirements of brushless DC motor applications. It uses high-power
  • MOSFETs, SVPWM, and FOC, achieving up to 99% efficiency in most cases. A powerful microprocessor brings comprehensive and precise control to the controller. It also allows users to quickly and easily adjust parameters, conduct tests, and obtain diagnostic information. The KLS controller can be programmed on both PC software and Android App.
  • The KHS features user-friendly I/O terminals, allowing customers to easily connect the battery and motor.

Caution!

  • Before running the motor, please start the auto-identification operation first.
  • And do not attempt to connect the controller to the user program or change settings in the user program or Android App while the motor is still running.
  • In other words, if you want to connect the controller to the user program or attempt to program, please stop the motor first. This is the first step you must take.

Features and Specification

  • Model Series: KHS
  • Voltage: Up to 360V
  • Supported Devices:
    • KHS32020I, KHS36020I, KHS32020IPS, KHS36020IPS, KHS32020IA, KHS36020IA
    • KHS32030N, KHS32035N, KHS32040N, KHS36025N, KHS36030N, KHS36035N

General functions

  1. Extended fault detection and protection. Customers can read the error message in PC software or Android APP also.
  2. Monitoring battery voltage. The controller will stop driving if the battery voltage is too high. When the battery voltage is low, it will progressively cut back motor drive power as the battery voltage drops. It will also stop driving if the battery voltage reaches the preset “Low Battery Voltage” value.
  3. Built-in current loop and over current protection.
  4. Configurable motor temperature protection range.
  5. Current cutback at low temperature and high temperature to protect battery and controller. The current begins to ramp down at 90℃ case temperature, shutting down at 100℃.
  6. The controller keeps monitoring battery recharging voltage during regen braking.
  7. Maximum reverse speed and forward speed can be configured between 20% and 100% respectively and separately.
  8. The controller can be programmed and configured using user program or an Android app. For the PC side, please connect the controller and PC using a Kelly USB cable or a USB-RS232 set to use the user program. For the Android side, please connect the controller to a Bluetooth adapter which purchased from out site to use the configuration app on Android devices.
  9. Provision of a +5 volt and +12 volt output to supply various kinds of hall sensors and switches.
  10. Multiple switches inputs. By default, the switch is effective when the voltage value is 12V.
  11. 3 analog inputs (signal is 0-5V), the default are throttle analog input, brake analog input, and motor temperature input.
  12. The controller will copy the pulse signal of A-phase Hall sensor for use in the pulse speedometer.
  13. Configurable boost function. Enables the maximum motor output if the boost switch is turned on. Regardless of the throttle position, the effect will be the same as full throttle.
  14. Configurable joystick throttle. A bi-symmetrical 0-5V signal for both forward and reversing.
  15. Configurable motor over-temperature detection and protection with the recommended thermistor KTY84-130/150 or KTY83-122.
  16. Only support three-phase hall position sensors. Open collector, pull up provided.
  17. At Brake analog regen mode, controller needs another analog input as brake input.
  18. Enhanced regen brake function. A novel ABS technique provides powerful and smooth regen. The regen can start at any speeds.
  19. Cruise control. Only can be activated in forward direction.
  20. Bluetooth supported. Required a Bluetooth adapter which needs to be purchased in addition from our website. This adapter is only useful for KLS controller.
  21. User customization on the serial port communication is supported.
  22. CAN Bus (Optional), broadcast type, with a customizable baud rate(default at 250Khz) . CAN bus is not included by default in KHS controllers.
  23. Bidirectional anti-slip function (Optional), Prevent the stationary vehicle moving in the opposite direction. After the function enabled, when the controller detects that the motor turns from standstill to the opposite direction, it will drive the motor to provide some braking force, making the vehicle stops or slows down. The braking force can be set as required.
  24. Electric-magnet brake (Optional).
  25. Weak Magnetic Speed Boost Function (Optional).
  26. Anti-theft function (Optional), an external alarm is required.
  27. Other functions required by the user, require additional customization.
    • Caution! For safety reasons, regen must be used together with mechanical brakes.

Features

  1. Smart Control with Powerful Microprocessor.
  2. Synchronous rectification, ultra-low voltage drop, fast SVPWM and FOC for very high efficiency.
  3. Electronic commutation.
  4. Monitoring of 3 motor phases, power bus, and power voltage.
  5. Monitoring of 12V and 5V voltage sources.
  6. Detection of current in all 3 motor phases.
  7. Current control loop.
  8. Hardware overcurrent protection.
  9. Hardware overvoltage protection.
  10. Configurable motor current and battery current limits.
  11. Low EMC.
  12. Battery protection: current reduction, warning, and shutdown at configured high and low voltage levels.
  13. The PCB is mounted on an aluminum base plate with a heat sink on the bottom of the controller.
  14. Various connector sets which supporting small signals, with waterproof connector set by default.
  15. Thermal protection: current reduction, warning, and shutdown at high temperatures.
  16. Automatic identification feature for Hall sensors mounted at any angle.
  17. Configurable high pedal protection: if high throttle is detected at startup, the controller will not operate.
  18. Current multiplication: drawing less current from the battery while outputting more current to the motor.
  19. Easy installation: Operates with Just a 3-Wire Potentiometer.
  20. Programming via standard PC/laptop,user program provided. Easy to use. No cost to customers.
  21. Supports motors with any number of poles.
  22. Standard electrical speed up to 70,000 eRPM (electrical speed = mechanical speed * number of pole pairs; number of pole pairs = number of poles / 2).
  23. Dust-proof and waterproof under sealed conditions, IP66.

Specifications

  1. Frequency of Operation: 10KHz, 16KHz, 20KHz.
  2. Standby Battery Current: < 0.5mA.
  3. 5V or 12V Sensor Supply Current: 40mA.
  4. Supply(PWR) Current: 30mA Typical.
  5. Battery voltage(B+) range: Configurable.
  6. Standard Throttle Input: 0-5V(3-wire resistive pot), 1-4V(hall active throttle).
  7. Full Power Operating Temperature Range: 0℃ to 70℃(MOSFET temperature).
  8. Operating Temperature Range: -40℃to 100℃ (MOSFET temperature).
  9. Max Battery Current: Configurable.
  10. Max Motor Current: Configurable.

Name Regulation

The name regulation of Kelly BLDC motor controllers:

  • For example: KHS32020I/KHS32030NPS
  • KHS: Kelly optical-isolated BLDC motor controller based on sinusoidal waveform which is suitable for operation under high voltage. KHS controllers can do regen brake function by default.
  • 320: 320V battery pack.
  • I: Standard housing, smaller and lighter than N model, compatible with Hall sensors. Liquid cooled by default.
  • N: Sealed aluminum housing,Enhanced cooling performance,compatible with Hall sensors. Liquid cooled by default.
  • IPS: Standard housing, smaller and lighter than N model, compatible with Sin/Cosine sensors. Liquid cooled by default.
  • NPS: Sealed aluminum housing,Enhanced cooling performance,compatible with Sin/Cosine sensors. Liquid cooled by default.
  • IA: Standard housing, smaller and lighter than N model, compatible with ABZ Encoders. Liquid cooled by default.
  • NA: Sealed aluminum housing,Enhanced cooling performance,compatible with ABZ Encoders sensors. Liquid cooled by default.
Kelly KHS High Voltage Sine Wave Brushless DC Motor Controller
Model Nominal

Voltage(Volt)

Peak Current

2 Minute (Amp)

Continuous

Current(Amp)

KHS32020I/IPS/IA 18-380 200 80
KHS32030N/NPS/NA 18-380 300 150
KHS32035N/NPS/NA 18-380 350 175
KHS32040N/NPS/NA 18-380 400 200
KHS36020I/IPS/IA 18-450 200 80
KHS36025N/NPS/NA 18-450 250 125
KHS36030N/NPS/NA 18-450 300 150
KHS36035N/NPS/NA 18-450 350 170
Note: Continuous current was calculated based on controller with liquid cooling bottom plate.

Wiring and Installation

Mounting the Controller

  • The controller can be placed anywhere but should be kept as clean and dry as possible.
  • If necessary, covering with a cover to prevent water and contaminants from entering.
  • To ensure full rated output power, the controller should be mounted on a clean, flat metal surface and secured with screws on all four mounting holes. Apply silicone grease or other thermally conductive material to the contact surfaces to enhance thermal performance.
  • Proper heat sinking and airflow are vital to achieve the full power capability of the controller.
  • The case outline and mounting holes’ dimensions are shown below.

Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (1)Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (13)

Connections
Pin definition of KHS Controller

Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (2)

DJ7091Y-2.3-11 Pin Definition

  1. REV_SW(14): Reverse switch input. ※Orange
  2. GND(6): Signal return or power supply return. ※Black
  3. FWD(12): Forward switch or can be enabled as High speed switch function. ※
    White
  4. 12V(11): 12V Supply. ※Red
  5. 12V (25): brake switch. ※Yellowish
  6. ECO(22): Low speed switch. ※Blue
  7. CAN-H(33): (Optional function). ※Greenish
  8. PWR(7): Controller power supply (input). ※Pink
  9. CAN-L(34): (Optional function). ※Brownish

DJ7091Y-2.3-21 Pin Definition

  1. Foot_SW(15): Throttle switch input. ※Gray
  2. Throttle(3): Throttle analog input, 0-5V. ※ Green
  3. GND(20): Signal return. ※Black
  4. Meter(8): Copied signal of hall-A sensor. ※Dark Gray
  5. 5V(4): 5V Supply, <40mA. ※Purple
  6. Brake_AN(2): Brake variable regen or Boost function. ※Brown
  7. 12V(11): 12V Supply. ※Red

DJ7061Y-2.3-21 Pin Definition

  1. GND(21): Signal return. ※Black
  2. Temp(1): Motor temperature sensor input. ※Raddle.
  3. 5V(5): 5V Supply, <40mA. ※Purple
  4. Hall A(18): Hall sensor signal of phase-A. ※Yellow (Also used as Sine signal input on KHS-NPS)
  5. Hall B(17): Hall sensor signal of phase-B. ※Dark Green (Also used as Cosine signal input on KHS-NPS)
  6. Hall C(16): Hall sensor signal of phase-C. ※Dark Blue (This port is reserved on KHS-NPS)

35pin connector definition

Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (3)

776164 Pin Definition

01     CTR_PWR(KEY) 02     COIL_RLY- 03     REV_SW 04     FWD_SW 05     12V_OUT
06     TPS2 07     GND 08     VS_5V 09     FOOT_SW 10     12V_OUT
11     CAN_H 12     12V_OUT 13     CTR_PWR(COIL_RLY+) 14     ECO 15     VS_5V
16     SC 17     SA 18     SB 19     ACC_SW 20     TPS
21     TX 22     RX 23     METER 24     ALARM 25     SD
26     BRK_AN/SW 27     GND 28     GND 29     GND 30     MOT_TEMP
31     GND 32     GND 33     GND 34     CAN_L 35     35 GND
  1. PWR(7): Controller power supply (input).
  2. Reserved*.
  3. REV_SW(14): Reverse switch input
  4. FWD(12): Forward switch or can be enabled as High speed switch function.
  5. 12V(11): 12V Supply.
  6. Reserved*.
  7. GND(6): Signal return or power supply return.
  8. 5V(5): 5V Supply, <40mA.
  9. 12V (25): brake switch.
  10. 12V(V+): 12V Supply for Communication Port.
  11. CAN-L(34): (Optional function).
  12. 12V(11): 12V Supply.
  13. Reserved*.
  14. ECO(22): Low speed switch.
  15. 5V(4): 5V Supply, <40mA.
  16. Hall C(16): Hall sensor signal of phase-C. (This port is reserved on KLS-8080NPS)
  17. Hall A(18): Hall sensor signal of phase-A. (Also used as Sine signal input on KLS-8080NPS)
  18. Hall B(17): Hall sensor signal of phase-B. (Also used as Cosine signal input on KLS-8080NPS)
  19. Foot_SW(15): Throttle switch input.
  20. Throttle(3): Throttle analog input, 0-5V.
  21. Tx of Communication Port.
  22. Rx of Communication Port.
  23. Meter(8): Copied signal of hall-A sensor.
  24. Reserved*.
  25. Reserved*.
  26. Brake_AN(2): Brake variable regen or Boost function.
  27. 27-28,31-32: Reserved GND.
  28. GND(20): Signal return.
  29. Temp(1): Motor temperature sensor input.
  30. GND(V-): GND for Communication Port.
  31. CAN-L(34): (Optional function).
  32. GND(21): Signal return.

Notes:

  1. PWR(7) should be connected to a 12V independent battery or a 12V DC-DC converter
  2. All GND pins are internally connected.
  3. Meter function is to output signal of hall-A sensor.
  4. Three gears and three speeds function can’t be used at the same time by default. Because FWD in three gears and High-speed in three speeds are using the same pin (FWD, Pin12).
  5. The switch signal is valid at 12V.
  6. 12V outpu(t Pin11)can only be used for switch signals, with a total current not exceeding 40mA.
  7. CAN bus is not included in KHS controller by default.
  8. Boost and brake analog regen use the same port on Brake_AN(Pin2). When boost is disabled in user program, Pin2 is used for brake analog regen. When boost is enabled, Pin2 is used for boost function. Due to port conflicts, these two functions can’t operate simultaneously on the same port.
  9. Reserved*: Can be customized to implement other functions.

KHS Controller Standard Wiring

Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (4)Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (5)

Caution!

  • Make sure the controller wiring is correct and has been double checked, especially the
  • B+ and the B- of the controller before power on. Wiring faults will damage the controller.
  • Ensure that the B- wiring is securely and properly connected before applying power.
  • The preferred connection of the system contactor or circuit breaker is in series with the B+ line.
  • Contactors in the B+ line must have a diode across their coils. It was used as freewheel diode. Lacking of this diode may cause serious damage to the power module. Please install this diode as KHS controller standard wiring showing above.

Communication Port
A 4pin connector is provided to communicate with host for calibration and configuration.

Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (6)

Installation Check List

  1. Conduct a visual inspection to ensure that components such as mounting holes, wiring, and sealing rings are intact.
  2. Check the connection between the battery B+ and NC. For controllers without a fuse, check the connection between the battery B+ and the controller B+ instead of NC.
  3. Check the connection between the battery B- and the controller B-.
  4. Verify the connections of all signal wires and ensure that their PWR and GND are properly isolated from each other.
  5. Check the connection of the motor’s Hall wires, the 5V and GND wires should correspond with the motor’s interface.
  6. Verify the connection of the throttle wires, the 5V and GND wires should correspond with the throttle’s interface.
  7. Check the connection of the gear wires. It is valid at 12V by default.

Configuration Program

  • KLS Configuration program allows users to adjust various parameters according to their needs, enabling the motor to achieve optimal performance. The default parameters may not be suitable for all situations. Please ensure that all parameters are adjusted to appropriate values before testing to avoid any potential dangers. Customers can program using either a PC program or an Android app.
  • Before operating the motor, an automatic identification process must be performed. During the process, the controller needs to be connected to the batteries, motor, and throttle. And the PWR(Pin7) needs to be connected with battery B+ to power the controller.
  • Please perform the automatic identification process according to the automatic identification guide showed in chapter 4.2.

Notes.

  1. When configuring existing parameters in the user program or Android app, disconnect the controller from the motor or at least stop the motor.Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (7)
  2. The controller may display fault codes when adjusting parameters, but it will not affect programming or configuration. However, it will affect the auto-identification operation, so please try to eliminate error codes before performing the auto-identification operation.
  3. Use the RS232-USB cable and SM-4P adapter provided by Kelly to connect to a host computer. During the operation, the PWR of the controller needs to be provided with >+18V (for a 24V controller, provide >+8V). Connect the GND to battery B- .
  4. To connect to Android devices, KLS controller requires a Bluetooth adapter.

Connecting to upper host.

You have three ways to connect the controller to host computers or Android devices:

  1. Using Kelly USB cable, connect SM-4P (Female) from controller to the USB port on computer. You may download Kelly USB Cable driver or at our website. (https://media.kellycontroller.com/new/CH341SER.zip)Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (8)
  2. Using RS232-USB cable along with SM-4Pin adapter, connect SM-4Pin(Female) from controller to the USB port on computer. You may download USB-RS232 driver at our website. (https://media.kellycontroller.com/new/USB-CONVERTER-RS232-Win10.zip)Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (9)
  3. Using Bluetooth adapter. Connect it to SM-4P (Female) then connect the controller to Android devices through Bluetooth. This Bluetooth adapter can be purchased from our website.(https://kellycontroller.com/shop/usb-adapter)Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (10)

How to use auto-Identification.
Here is a brief overview of the automatic identification process:

  1. Connect the controller and the motor according to the standard wiring diagram (Figure 11). Please make sure there is no load on the motor shaft before starting the programming.
  2. Connect the controller to PC by using a Kelly USB cable or an USB to RS232 set. For Android devices, please use the Bluetooth adapter to connect the controller.
  3. Download the corresponding USB drivers and the user program from our website, only one driver can be installed, two drivers installed at same time are incompatible. After the USB driver is successfully installed, please restart your PC.
  4. Turn the key switch to supply power to the controller from B+/B- and PIN7, then open the user program on your device. Click the ‘READ’ button to open the initial interface as the figure below.Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (11)
    • Please check whether the value of Identification_Angle is at 85. The 85 means this controller had finished the automatic identification operation with the motor in factory before.
    • It is still needed to run automatic identification operation before running.
  5. Fill 170 in the Identification_Angle value. Then click the write button. The user program will give a pop-up window which shows the Write operation is succeeded. Then exit from the user program and turn off the power supply.
  6. Turn on the power supply after the power supply is off for a few seconds. The motor shaft will try to run on random directions. This is a normal operating phenomenon.
  7. Wait about 2-3 minutes.
  8. The indicator will show error code 3-2, means automatic identification operation is finished normally. And you will see reset error message in the monitor screen of user program.
  9. Turn off the power supply again, then wait about a few seconds to turn on the power supply again.
  10. Connect the controller to user program. You will see 85 in the Identification_Angle. Means, the controller auto-identification operation is succeeded. The motor is ready to run.
  11. If the Identification_Angle value is 170, it means that auto-identification is still in progress.
  12. If no error code is triggered, please do not manually write 85 to Identification_Angle or restart the power supply.
  13. If a constant error code lasts above 5 minters and there are other error codes such as Identify error, hall error etc, please return to the initial interface of user program and write 85 to Identification_Angle manually.
  14. Before turn off the power supply, make sure that Identification_Angle is not at 170. Otherwise the controller will try to keep doing the identification operation all the time after you turn on power supply again.When the error codes occur, please quit from user program and try step 6 again.
  15. After successful identification, make sure that Identification_Angle is not at 170. Then you may turn on the power supply.
  16. If the direction of the motor is not what you expected, there is no need for you to operate again, just check the Change Direction option in the last part of initial interface then click Write button and reset, the motor will run on the opposite direction.
  17. For NPS model (with sin/cosine sensors), please set Speed_sensor to 4 first. And set Motor_Poles to an appropriate value according to your motor. Then fill the Line_Hall_Zero, Line_Hall_Amplitude and Line_Hall_High, Line_Hall_Low with appropriate values. Line_Hall_Zero= [HA_AD(max)+HA_AD(min)]*2 or [HB_AD(max)+HB_AD(min)]*2 = Zero point voltage(V)*1024/5 Line_Hall_Amplitude= [HA_AD(max)-HA_AD(min)]*2 or [HB_AD(max)-HB_AD(min)]*2 = Signal amplitude(V) *1024/5

For high voltage controllers, additional steps are required during automatic angle identification, involving the pre-charge circuit board. The steps are as follows:

Kelly-KHS-Series-High-Voltage-Opto-Isolated-Sinusoidal-BLDC-Motor-Controllers-fig- (12)

  • The controller includes a pre-charge circuit board between B + and NC terminal.
  • First, connect a lower voltage (e.g. 24V-72V) to B +, the customer must set the pre-charge voltage to 0V in the user program before the controller can automatically identify.
  • When the identification angle operation is successfully completed, you need to set the pre-charge voltage and pre-charge time in the user program.
  • Then connect the positive pole of the high-voltage battery to NC to reach the pre-charge voltage set previously.

Pre-charge voltage range:

  • For 320V series, it should be 0-380V;
  • For 360V series, it should be 0-450V.
    Pre-charge time: 0-200 (corresponding to the actual time 0-20S).
  • Customers can configure the target pre-charge voltage to be completed within the pre-charge time according to the battery characteristics.

Program parameters and value
On program’s initial interface, these items are listed:

 

Number

 

Parameter

Possible

Value

Default

Value

 

Description

Source of

Value*

1 Model Name     Controller Model. Default
2 User Name     User code, to identify controller variants. Default
3 Serial Number     Serial Number. Default
4 Software Version     Software Version. Default
5 Controller Volt 0-144   Controller Voltage(V). Default
 

 

6

 

 

Low Volt

 

 

18-180

  Minimum normal voltage(V),

In order to protect the battery, if the battery voltage is lower than this value, the controller will not work.

 

User Configuration

 

 

7

 

 

Over Volt

 

 

18-180

  Maximum normal voltage(V),

In order to protect the battery, if the battery voltage is high1er than this value, the controller will not work.

 

User Configuration

8 Hall 0-1000   Hall Galvanometer Rate(A). Default
9 PhaseCurr Max 409-2048   The Max AD value of phase current. Default
  AD        
 

10

 

Motor_Current

 

20-100%

 

100%

The ratio range of the motor phase current to the controller

peak current.

User

Configuration

 

 

 

 

11

 

 

 

 

Battery_Current

 

 

 

 

20-100%

 

 

 

 

50%

Maximum battery current.

Used to set the upper limit of battery current to protect the battery. A lower value will limit the battery output current more and protect the battery more effectively. However, if this value is too low, it will affect acceleration.

 

 

 

User Configuration

 

 

 

 

12

 

 

 

 

Identify Angle

 

 

 

 

85 / 170

 

 

 

 

85

Status of identification:

85:normal operation.

170: A reboot is required to automatically identify the sensor angle. Once identification is complete, this value will be reset to 85.

 

 

 

 

Auto

 

 

13

 

 

TPS Low Err

 

 

0-20%

 

 

0%

Hall pedal parameter, only valid when TPS type is set to 2. When the actual value is lower than this value, the controller will report a TPS type error,

20%*5V=1V

 

 

User Configuration

 

 

14

 

 

TPS High Err

 

 

80-100%

 

 

95%

Hall pedal parameter, only valid when TPS type is set to 2. When the actual value is higher than this value, the controller will report a TPS type error,

80%*5V=4V

 

 

User Configuration

 

 

15

 

 

TPS Type

 

 

1 / 2

 

 

1

Throttle Type,

1: 0-5K,resistance pedal; 2: 0,5V,Hall active pedal;

 

User Configuration

 

16

 

TPS Dead Low

 

0-60%

 

20%

Throttle Dead Zone Lower Limit,

20%*5V=1V.

User

Configuration

 

17

 

TPS Dead High

 

60-95%

 

80%

Throttle Dead Zone Higher Limit,

80%*5V=4V.

User

Configuration

 

18

 

TPS Fwd MAP

 

0-100%

 

30%

When moving forward, the MAP value corresponding to

throttle midpoint, to adjust throttle response amplitude.

User

Configuration

 

19

 

TPS Rev MAP

 

0-100%

 

20%

When moving backward, the MAP value corresponding to

throttle midpoint, to adjust throttle response amplitude.

User

Configuration

 

 

20

 

 

Brake Type

 

 

0 /1 / 2

 

 

0

Regen braking mode 0: Switch regen mode.

1:0-5K, resistance pedal regen.

2:0-5V, hall active pedal regen.

 

 

User Configuration

 

21

 

Brake Dead Low

 

5-40%

 

20%

Brake Dead Zone Lower Limit,

20%*5V=1V.

User

Configuration

22 Brake Dead High 60-95% 80% Brake Dead Zone Upper Limit, User
        80%*5V=4V. Configuration
 

23

 

Max Output Fre

 

50-1200

 

1000

 

Max output Frequency(Hz).

User

Configuration

 

24

 

Max Speed

 

0-16000

 

4000

 

Motor max speed (RPM).

User

Configuration

 

25

 

Max Fwd Speed

 

0-100%

 

100%

 

Maximum forward speed to the motor max speed .

User

Configuration

 

26

 

Max Rev Speed

 

0-100%

 

100%

 

Maximum reverse speed to the motor max speed.

User

Configuration

 

27

MidSpeed Forw

Speed

 

0-100%

 

50%

 

Maximum forward speed in the middle speed gear .

User

Configuration

 

28

MidSpeed Rev

Speed

 

0-100%

 

30%

 

Maximum reverse speed in the middle speed gear .

User

Configuration

 

29

LowSpeed Forw

Speed

 

0-100%

 

50%

 

Maximum forward speed in the low speed gear .

User

Configuration

 

30

LowSpeed Rev

Speed%

 

0-100%

 

30%

 

Maximum reverse speed in the low speed gear.

User

Configuration

 

 

 

 

31

 

 

 

 

Three Speed

 

 

 

 

0 / 1 / 2

 

 

 

 

0

Number of speed modes:

0: one speed mode: maximum speed mode.

1:two speed modes: middle speed mode and maximum speed mode .

2:three speed modes:low speed mode, middle speed mode

and maximum speed mode.

 

 

 

User Configuration

 

32

 

PWM frequency

 

10 / 16 / 20

 

16

 

PWM modulation frequency (Khz)

User

Configuration

 

 

 

33

 

 

 

IQ Kp

 

 

 

0-32767

 

 

 

500

Kp of Q-ring, the proportional gain in Q-ring current loop, is mainly effective at speeds below 400 RPM. Increasing this value will accelerate the response speed but will increase startup jitter; decreasing this value will reduce startup jitter but

will also decrease the response speed.

 

 

User Configuration

 

 

 

34

 

 

 

IQ Ki

 

 

 

0-32767

 

 

 

10

Ki of Q-ring, the integral gain in Q-ring current loop, is mainly effective at speeds below 400 RPM. Increasing this value will improve current accuracy but will increase startup jitter and instability. Decreasing this value will enhance stability and

reduce startup jitter but will also lower current accuracy.

 

 

User Configuration

 

 

 

35

 

 

 

ID Kp

 

 

 

0-32767

 

 

 

1500

Kp of D-ring, the proportional gain in D-ring speed loop, is mainly effective at speeds below 400 RPM. Increasing this value will accelerate the response speed but will increase high-speed jitter; decreasing this value will reduce high-speed

jitter but will also decrease the response speed.

 

 

User Configuration

 

36

 

ID Ki

 

0-32767

 

30

Ki of D-ring, the integral gain in D-ring current loop, is mainly

effective at speeds below 400 RPM. Increasing this value will

User

Configuration

        improve speed accuracy but will increase high-speed jitter

and instability. Decreasing this value will enhance stability and reduce high-speed jitter but will also lower speed accuracy.

 
 

 

 

37

 

 

 

HS_ACQR_Kp

 

 

 

0-32767

 

 

 

2000

Kp of Q-ring, the proportional gain in Q-ring current loop, is mainly effective at speeds above 400 RPM. Increasing this value will accelerate the response speed but will increase startup jitter; decreasing this value will reduce startup jitter but

will also decrease the response speed.

 

 

User Configuration

 

 

 

38

 

 

 

HS_ACQR_Ki

 

 

 

0-32767

 

 

 

60

Ki of Q-ring, the integral gain in Q-ring current loop, is mainly effective at speeds above 400 RPM. Increasing this value will improve current accuracy but will increase startup jitter and instability. Decreasing this value will enhance stability and

reduce startup jitter but will also lower current accuracy.

 

 

User Configuration

 

 

 

39

 

 

 

HS_ACDR_Kp

 

 

 

0-32767

 

 

 

5000

Kp of D-ring, the proportional gain in D-ring speed loop, is mainly effective at speeds above 400 RPM. Increasing this value will accelerate the response speed but will increase high-speed jitter; decreasing this value will reduce high-speed

jitter but will also decrease the response speed.

 

 

User Configuration

 

 

 

40

 

 

 

HS_ACDR_Ki

 

 

 

0-32767

 

 

 

100

Ki of D-ring, the integral gain in D-ring current loop, is mainly effective at speeds above 400 RPM. Increasing this value will improve speed accuracy but will increase high-speed jitter and instability. Decreasing this value will enhance stability and

reduce high-speed jitter but will also lower speed accuracy.

 

 

User Configuration

 

41

 

BRK_AD Brk

 

0-50%

 

0%

Brake pedal regen’s regen strength,

0= no regen.

User

Configuration

 

42

 

Anti-theft

 

0-30%

 

15%

When the anti-theft function is activated, the percentage of the

motor’s locking current to the maximum current.

User

Configuration

 

43

 

Brk_Speed Limit

 

0-500

 

0

Minimum motor speed to activate regen brake (RPM), RPM

below this value will exit regen.

User

Configuration

 

44

 

RLS_TPS Brk

 

0-50%

 

0%

Pedal releasing regen ‘s regen strength,

0= no regen.

User

Configuration

 

45

 

NTL Brk

 

0-50%

 

0%

Neutral gear regen ‘s regen strength,

0= no regen.

User

Configuration

 

46

 

Accel Time

 

1-250

 

5

Torque mode accelerate Time,

the time of torque from 0 to max,(X0.1second)

User

Configuration

 

47

 

Accel Rls Time

 

1-250

 

1

Torque mode accelerate release delay Time,

the time of torque from max to 0,(X0.1second)

User

Configuration

 

48

 

Brake Time

 

1-250

 

5

Torque mode Brake Time,

the time of Brake Torque from 0 to max,(X0.1second)

User

Configuration

 

49

 

Brake Rls Time

 

1-250

 

1

Torque mode Brake release Time,

the time of Brake Torque from max to 0,(X0.1second)

User

Configuration

50 BRK_SW Brk 0-50% 10% Switch regen ‘s regen strength. User
        0= no Switch regen. Configuration
 

51

 

Change Dir Brk

 

0-50%

 

5%

Change direction regen‘s regen strength.

0= no Change direction regen.

User

Configuration

 

52

 

Compensation

 

0-100%

 

20%

 

Compensation current of anti-slip function.

User

Configuration

 

 

53

 

 

IVT BRK Max

 

 

0-10000

 

 

10000

Maximum motor speed for enable Change direction regen(RPM)  

User Configuration

 

54

 

IVT BRK Min

 

0-5000

 

50

Minimum motor speed for enable Change direction regen

(RPM)

User

Configuration

 

 

 

 

55

 

 

 

 

Torque Speed Kp

 

 

 

 

0-10000

 

 

 

 

3000

Kp of Q-ring in torque mode,

the proportional gain in Q-ring current loop, is mainly effective at speeds below 400 RPM. Increasing this value will accelerate the response speed but will increase startup jitter; decreasing this value will reduce startup jitter but will also

decrease the response speed.

 

 

 

User Configuration

 

 

 

 

56

 

 

 

 

Torque Speed Ki

 

 

 

 

0-500

 

 

 

 

80

Ki of Q-ring in torque mode

the integral gain in Q-ring current loop, is mainly effective at speeds below 400 RPM. Increasing this value will improve current accuracy but will increase startup jitter and instability. Decreasing this value will enhance stability and reduce startup jitter but will also lower current accuracy.

 

 

 

User Configuration

 

 

57

 

 

Speed Err Limit

 

 

50-4000

 

 

1000

Limit of Kp and Ki in torque mode, need to be adjusted at same time when adjusting

Kp and Ki in torque mode.

 

User Configuration

 

58

 

Precharge_Vol

 

0-360

 

0

 

Target Voltage of Pre-charging ( V ).

User

Configuration

 

59

 

Precharge Time

 

5-20

 

20

 

Time for pre-charging( S )

User

Configuration

 

60

 

Motor Nominal

 

0-1000

 

80

 

Motor Current when identification(A)

User

Configuration

 

 

61

 

 

Motor Poles

 

 

2-128

 

 

8

Number of motor poles, equal to 2* pole pairs.

When used for hub motors, reducing this value by multiples, such as from 8 to 4, can improve the speed measurement

accuracy.

 

 

User Configuration

 

 

 

62

 

 

Speed Sensor Type

 

 

 

2 /3/ 4

 

 

 

2

Sensor Type:

2.          Hall sensor

3.          Magnetic encoder.

4.          Linear Hall sensor(sine/cosine sensors) 5.

 

 

User Configuration

 

63

 

Resolver Poles

 

2-32

   

Reserved.

User

Configuration

 

 

 

64

 

 

 

Min Excitation

 

 

 

0-100

 

 

 

0

Minimum excitation coefficient (A)

This value affects the current and maximum speed of the motor when the field weakening function is enabled.

When this value = 0, the field weakening function has no

actual effect

 

 

User Configuration

 

 

65

 

 

Motor Temp

 

 

0 / 1 / 2

 

 

0

Temperature sensor type, 0:none.

1: KTY84-130 and KTY84-150

2: KTY83-122

 

 

User Configuration

 

66

 

High Temp Cut ℃

 

60-170

 

150

Temperature for triggering the motor’s high temperature cut

off.

User

Configuration

 

67

 

Resume ℃

 

60-170

 

110

When the temperature drops back to this value, high

temperature resume will be triggered.

User

Configuration

 

68

 

High Temp Str℃

 

0-170

 

100

 

starting temperature for high-temperature weakening. (℃)

User

Configuration

 

69

 

High Temp weak

 

0-100%

 

50%

 

The strength of high-temperature weakening (%)

User

Configuration

 

 

70

 

 

Line Hall Zero

 

 

1-1023

  Zero point of sine/cosine sensor signal, this value / 1024 * 5 = actual voltage value (Volts).

Available for sine/cosine sensor

 

User Configuration

 

 

 

71

 

 

Linear Hall Amplitude

 

 

 

1-1024

  Signal amplitude of sine/cosine sensor signal.

this value / 1024 * 5 = actual voltage value (Volts). When this value is below 153.6 or above 256,the signal voltage is error.

Available for sine/cosine sensor

 

 

User Configuration

 

 

72

 

 

Line Hall High

 

 

1-1023

  An error will be reported when the amplitude of the sine/cosine sensor signal exceeds this value.

this value / 1024 * 5 = actual voltage value (Volts).

Available for sine/cosine sensor

 

 

User Configuration

 

 

73

 

 

Line Hall Low

 

 

1-1023

  An error will be reported when the amplitude of the sine/cosine sensor signal is below this value.

this value / 1024 * 5 = actual voltage value (Volts).

Available for sine/cosine sensor

 

 

User Configuration

 

 

 

 

74

 

 

 

Swap Motor Phase

 

 

 

 

0 / 1 /255

 

 

 

 

0

Swap phase function status 0: disabled

1: enabled,

255: error.

Available for sine/cosine sensor

 

 

 

 

Default

 

 

75

 

Synchro Initial Angle

 

 

0-65535

 

 

8192

Synchro Initial Angle , defines the reference point of the position when sensor type is set to 4.

Available for sine/cosine sensor

 

 

Default

76 0°  Hall value 0-7 2 Hall sensor sequence value at motor electrical angle 0°. Auto
77 60° Hall value 0-7 6 Hall sensor sequence value at motor electrical angle 60° Auto
78 120°Hall value 0-7 4 Hall sensor sequence value at motor electrical angle 120° Auto
79 180°Hall value 0-7 5 Hall sensor sequence value at motor electrical angle 180° Auto
80 240°Hall value 0-7 1 Hall sensor sequence value at motor electrical angle 240° Auto
81 300°Hall value 0-7 3 Hall sensor sequence value at motor electrical angle 300° Auto
 

 

82

 

Forward HA Rising edge

 

 

0-7

 

 

6

Forward Hall-A Rising edge sequence value  

 

Auto

 

83

Forward HA

Falling  edge

 

0-7

 

1

Forward Hall-A Falling edge

sequence value

 

Auto

 

84

Reverse HA Rising

edge

 

0-7

 

5

Reverse Hall-A Rising edge

sequence value

 

Auto

 

85

Reverse HA

Falling  edge

 

0-7

 

2

Reverse Hall-A Falling edge

sequence value

 

Auto

86 Brake_SW_Level 0-255   Brake_SW_Level Default
 

87

 

J CAN Address

 

0-255

 

5

CAN Address, when there are multiple CANs, different

addresses need to be set

User

Configuration

 

 

88

 

 

Startup H-Pedal

 

 

checked/ unchecked

 

 

checked

Startup High pedal function ,

Checked: From powerup, when the first time throttle being pressed, the controller will report a high pedal error to prevent accidental starting, need to step on the pedal again to start.

 

 

User Configuration

 

 

89

 

 

Brake H-Pedal

 

checked/ unchecked

 

 

unchecked

Brake High-pedal function

Checked: When press the brake and throttle at the same time, he controller will report a high pedal error to stop running.

 

User Configuration

 

 

90

 

 

NTL H-Pedal

 

 

checked/ unchecked

 

 

unchecked

Neutral High-pedal function

Checked: the first time throttle being pressed after switching gears, the controller will report a high pedal error to prevent accidental starting, need to step on the pedal again to start.

 

 

User Configuration

 

 

 

 

 

91

 

 

 

 

 

Joystick

 

 

 

 

checked/ unchecked

 

 

 

 

 

unchecked

Joystick throttle

Checked: enable joystick throttle, Its range:

0-2.5V: forward 2.5V: neutral

2.5V-5V: backward.

Has same range of dead zone as TPS dead zone.

 

 

 

 

User Configuration

 

 

92

 

 

Three Gears Switch

 

 

checked/ unchecked

 

 

unchecked

Three-gear function

Check: Enable three operating gears: Forward, Neutral, Reverse.

Uncheck: Forward only.

 

 

User Configuration

93 Boost checked/ unchecked Boost function, User
    unchecked   Checked: enable boost switch,

Connect Brake_AN (PIN2) to 12V to start boost.

Unchecked: Connect Brake_AN (PIN2) to 12V to start switch regen.

Configuration
 

 

94

 

 

Foot Switch

 

checked/ unchecked

 

 

unchecked

Thorttle switch

Checked: Connect Foot_SW to 12V to enable throttle, so motor can start.

 

User Configuration

 

 

95

 

 

SW Level

 

checked/ unchecked

 

 

checked

Defining which is the effective level of the switch. Checked: high level=enable.

Unchecked: low level=enable.

 

 

Default

 

 

96

 

 

0,HIM;1,KIM

 

checked/ unchecked

 

 

checked

Controller type Checked: KIM.

Unchecked: HIM.

 

 

Default

 

 

 

 

97

 

 

 

 

Cruise

 

 

 

checked/ unchecked

 

 

 

 

unchecked

Cruise function

Check: Enable the cruise function. Press and hold the accelerator for more than 3 seconds to enter the cruise mode. If the eRPM is lower than 4000, the controller will automatically exit the cruise mode.

 

 

 

User Configuration

 

 

 

98

 

 

 

Anti-theft

 

 

checked/ unchecked

 

 

 

unchecked

Anti-theft function

Checked: enable anti-theft function,

Need to connect to external anti-theft device. When the alarm is triggered, the motor will resist being turned.

 

 

User Configuration

 

 

99

 

 

Anti-Slip

 

 

checked/ unchecked

 

 

unchecked

Anti-Slip function

Checked: enable anti-slip function,

The motor will resist rotation to prevent the vehicle from moving due to external forces.

 

 

User Configuration

 

 

 

100

 

 

 

Change Direction

 

 

checked/ unchecked

 

 

 

unchecked

Change Direction function

Checked: Swap the forward and backward directions. Unchecked: no swap.

Used to correct the motor from moving opposite direction after

identification

 

 

User Configuration

Source of Value *:

  1. User: Users should modify these values to adjust the controller.
  2. Auto: These values are generated by the sensor or the controller’s program, and users can affect the operation of the controller by modifying these values.
  3. Default: These values are factory presets or sensor readings, cannot be modified by the user program.

Maintenance

Caution! There are no user-serviceable parts inside the controller. Do not attempt to open the controller on your own, as this will void your warranty. The exterior of the controller should be cleaned periodically. The controller is a high powered device. When working with any battery powered vehicle, proper safety precautions should be taken that include, but are not limited to propertraining, wearing eye protection, avoidance of loose clothing, hair and jewelry, using insulated tools.

Although the controller virtually requires no maintenance after proper installation, it is recommended to follow these steps during use:

  1. Disconnect the battery, starting with the positive terminal, to cut off the power.
  2. Discharge the capacitors in the controller by connecting a load (such as a contactor coil, resistor, or horn) across the controller’s B+ and B- terminals.
  3. Regularly remove any dirt or corrosion from the bus bar area. Wipe the controller with a moist rag and ensure it is completely dry before reconnecting the battery.
  4. Make sure the connections to the bus bars are tight. To avoid physically stressing the bus bars, use two well-insulated wrenches for the operation.
  5. Fanned model require routine fan maintenance, including ensuring the fan rotate normally and cleaning the dust on the fan.

Table 1: Error Codes

External LED Error Codes
To display the error code, please install an external LED indicator first.

Error code Explanation Solution
 

 

1, 1

 

 

¤

 

 

¤

 

Auto-Identification failed

1.     Check Phase line or Hall line.

2.     Check Hall power line(+5V and GND).

3.     The motor load maybe too high. Please unload the motor before proceeding with identification.

 

 

1, 2

 

 

¤

 

 

¤¤

 

 

Over voltage error

1.    Battery voltage is too high for the controller. Check battery volts and controller configuration.

2.    Regeneration over-voltage. Controller will limit regen or stop regen. please reduce the regen ratio in

configuration.

 

 

1, 3

 

 

¤

 

 

¤¤¤

 

 

Low voltage error

Battery voltage is too low, please check the battery and recharge.

When the battery voltage continuously exceeds the low

voltage cut-off value for 5 seconds, the controller will resume normal operation.

 

1, 4

 

¤

 

¤¤¤¤

The controller did not receive CAN

commands

 

Resend CAN commands from VCU.

 

2, 1

 

¤¤

 

¤

 

Motor stall

The motor did not reach 25eRPM within 2 seconds of

starting. Please check the Hall signal lines and the phase line connections.

 

 

 

 

 

 

2, 2

 

 

 

 

 

 

¤¤

 

 

 

 

 

 

¤¤

 

 

 

 

 

Internal voltage error

1.     Check the connection between PWR and B+(For 8080N series, check connection between PWR and

+12V; GND and -12V).

2.     The load on the 5V or 12V power supply could be too heavy, ensure that the measured voltage of the 5V power supply is not less than 4V and the voltage of the 12V power supply is not less than 8V. The lower these values are, the heavier the load on the power supply.

3.     If none of the above issues are present, the internal power module of the controller may be damaged. The

controller needs to be sent back to the factory.

2, 3 ¤¤ ¤¤¤ Over temperature The controller temperature is too high, about to stop.

Please wait until it restore to 80℃.

2, 4 ¤¤ ¤¤¤¤ Throttle error at

power on

Throttle signal is higher than the value of

“TPS_dead_low”at power-on. Release the throttle and

      press again or adjust the TPS_dead_low value. If still can’t

fix the issue, check if the throttle is functioning properly.

3, 1 ¤¤¤    ¤ Reserved  
 

3, 2

 

¤¤¤    ¤¤

Internal reset error Current is too high or current fluctuations are too large. Reduce the phase current and check if the 5V and 12V

power supplies are normal.

 

 

3, 3

 

 

¤¤¤    ¤¤¤

 

Hall throttle is open or

short-circuit

May occur after TPS_Type being set to 2.

1.     The throttle might have an internal short circuit or the ground wire might be disconnected.

2.     Set TPS_High_Err to 95 , check the throttle and its

wiring, then restart to fix the issue.

 

 

3, 4

 

 

¤¤¤    ¤¤¤¤

 

Angle sensor error

1.     Speed sensor type error,customers may set the correct sensor type through user program or App.

2.     Incorrect wiring.

3.     Speed sensor is damaged or defective. Or feedback signal is erratic.

4, 1 ¤¤¤¤    ¤ Switch-direction

error

1.     Throttle is not at 0 when switching motor direction.

2.     Motor rotation speed is above 50RPM.

4, 2 ¤¤¤¤    ¤¤ Reserved  
 

 

4, 3

 

 

¤¤¤¤    ¤¤¤

 

Motor

over-temperature

May occur after motor temp being set to 1 or 2.

The Motor temperature has exceeded the configured maximum value. The controller will shut down until the motor temperature cools down.

 

4, 4

 

¤¤¤¤    ¤¤¤¤

Hall Galvanometer

sensor error

 

Hall galvanometer inside the controller is damaged.

Error codes can be read through PC software or Android app.

Devices Supported:

KHS32020I KHS32030N KHS32035N KHS32040N
       
KHS36020I KHS36025N KHS36030N KHS36035N
       
KHS32020IPS KHS32030NPS KHS32035NPS KHS32040NPS
       
KHS36020IPS KHS36025NPS KHS36030NPS KHS36035NPS
       
KHS32020IA KHS32030NA KHS32035NA KHS32040NA
       
KHS36020IA KHS36025NA KHS36030NA KHS36035NA

Contact Us

FAQs

  • Q: Can the KHS motor controller be used with sensor-less brushless motors?
    • A: No, the KHS motor controller must be used with Hall sensors and does not support sensor-less brushless motors.
  • Q: What should I do before running the motor with the controller?
    • A: Start the auto-identification operation first before running the motor. Do not attempt to connect to the user program or change settings while the motor is running.

Documents / Resources

Kelly KHS Series High Voltage Opto Isolated Sinusoidal BLDC Motor Controllers [pdf] User Manual
KHS32020I, KHS32030N, KHS32035N, KHS32040N, KHS36020I, KHS36025N, KHS36030N, KHS36035N, KHS32020IPS, KHS32030NPS, KHS32035NPS, KHS32040NPS, KHS36020IPS, KHS36025NPS, KHS36030NPS, KHS36035NPS, KHS32020IA, KHS32030NA, KHS32035NA, KHS32040NA, KHS36020IA, KHS36025NA, KHS36030NA, KHS36035NA, KHS Series High Voltage Opto Isolated Sinusoidal BLDC Motor Controllers, KHS Series, High Voltage Opto Isolated Sinusoidal BLDC Motor Controllers, Opto Isolated Sinusoidal BLDC Motor Controllers, Isolated Sinusoidal BLDC Motor Controllers, Sinusoidal BLDC Motor Controllers, BLDC Motor Controllers, Motor Controllers, Controllers