JUNTEK-logo-

JUNTEK JDS2900 Series Dual-Channel Function Arbitrary DDS Signal Generator

 

JUNTEK-JDS2900 Series-Dual-Channe-Function-Arbitrary-DDS-Signal-Generator-

INSTALLATION INSTRUCTIONS

Check
When you get a new JDS2900 series dual-channel signal generator, it is recommended that you follow the steps below to check the instrument.

Check the package
If the package is damaged, keep the damaged packaging or shockproof material until the goods have been fully inspected and the instrument has passed electrical and mechanical tests. If the instrument is damaged due to shipping, please contact the shipper and the carrier for compensation.

Check accessories
The contents of accessories are as follows. If the contents do not match or the instrument is damaged, contact the dealer or the company.

  • Host: JDS2900 Series Dual Channel 1pcs
  • Signal Generator
  • Accessories: Power Adapter 1pcs
  • USB cable 1pcs
  • Signal connection cable 2pcs
  • User manual 1pcs

Check the whole machine
If you find that the instrument is damaged, the instrument is not working properly, or fails the performance test, contact your dealer or our company.

Contact Us
If you have any problem or requirement when using our products or this manual, please contact JUNTEK.

Instrument introduction

JDS2900 series function generator can generate multiple waveforms such as sine wave, square wave, triangle wave, pulse wave, and arbitrary wave. The frequency range up to 60MHz, with duty cycle adjustment, sweep frequency, frequency signal frequency and counter function, and the output signal, amplitude, and frequency can be displayed simultaneously. The series signal generator has excellent amplitude and frequency characteristics, the appearance of this instrument is exquisite and beautiful. This instrument is widely used in factories, schools, research institutes and laboratories.

The model description
This series of instruments are divided into three models, the main difference is the maximum frequency of sine wave output, as described below:

Model The max output frequency of sin wave
JDS2900-60M 60MHz
JDS2900-50M 50MHz
JDS2900-40M 40MHz
JDS2900-30M 30MHz
JDS2900-15M 15MHz

Technical parameters

Frequency characteristics
  JDS2900

-15M

JDS2900

-30M

JDS2900

-40M

JDS2900

-50M

JDS2900

-60M

 

Sine wave frequency range

 

0~15MHz

 

0~30MHz

 

0~40MHz

 

0~50MHz

 

0~60MHz

 

Square wave frequency range

 

 

 

0~15MHz

 

 

 

0-25MHz

 

 

 

0-25MHz

 

 

 

0-25MHz

 

 

 

0-25MHz

 

Triangle wave frequency range

 

Pulse wave frequency range

 

 

 

 

 

 

0~6MHz

 

 

 

 

 

 

0~6MHz

 

 

 

 

 

 

0~6MHz

 

 

 

 

 

 

0~6MHz

 

 

 

 

 

 

0~6MHz

 

TTL digital wave frequency range

 

Arbitrary frequency range

 

Pulse width adjustment range

 

 

100nS~4000S

 

50nS~4000S

 

40nS~4000S

 

30nS~4000S

 

25nS~4000S

 

Square wave rise time

 

≤25ns

 

≤15ns

 

≤10ns

 

≤10ns

 

≤10ns

 

Minimum frequency resolution

 

0.01uHz(0.00000001Hz)

 

Frequency accuracy

 

±20ppm

 

Frequency stability

±1ppm/3hours

±1ppm/3 hours

Waveform characteristics
 

 

 

Waveform type

 

Sine、Square、pulse (adjustable duty cycle, precise adjustment of pulse width and period), triangular wave, partial sine wave, CMOS wave, DC level (set DC amplitude by adjusting offset), half wave, full Wave, positive staircase wave, anti-ladder wave, noise wave, exponential rise, exponential drop, multisonic wave, Symplectic pulse and Lorenz pulse and 60 arbitrary waveforms

 

Wave length

 

2048 points

 

Waveform sampling rate

 

266MSa/s

 

Waveform vertical resolution

 

14-bits

 

 

 

 

Sine wave

 

Harmonic Suppression

 

≥45dBc(<1MHz); ≥40dBc(1MHz~20MHz)

Total harmonic distortion  

<1%(20Hz~20kHz,0dBm)

 

Square wave and pulse wave

 

Overshoot

 

≤5%

 

 

Pulse wave

 

Duty cycle adjustment range

 

 

0.1%~99.9%

 

 

Partial sine wave

 

Duty cycle adjustment range

 

 

0.1%~99.9%

 

Sawtooth wave

 

Linearity

 

≥98%(0.01Hz~10kHz)

Output characteristics
 

 

Sine wave amplitude range

 

Frequency ≤ 10MHz

 

10MHz ≤ Frequency ≤ 30MHz

 

30MHz ≤ Frequency

2mVpp~20Vpp 2mVpp~10Vpp 2mVpp~5Vpp
 

 

Square wave 、Triangle wave amplitude range

 

Frequency ≤ 10MHz

 

10MHz ≤Frequency ≤25MHz

 

2mVpp~20Vpp

 

2mVpp~5Vpp

 

Amplitude resolution

 

1mV

 

Amplitude stability

 

±0.5%/5 hours

 

Flatness of amplitude

 

±5%(<10MHz); ±10%(>10MHz)

Waveform output
 

Output impedance

 

50Ω±10% (typical)

 

Protection

 

All signal outputs can work within 60 when the load is short-circuited.

DC offset
 

 

Offset adjustment range

 

Output amplitude > 2V

 

0.2V <Output Range ≤ 2V

 

0<Output amplitude

≤0.2V

 

-9.99V~9.99V

 

-2.5V~2.5V

 

-0.25V~0.25V

 

Offset resolution

 

0.01 V

Phase characteristics
 

Phase adjustment range

 

0~359.9o

 

Phase resolution

 

0.1o

TTL/CMOS output
 

Low level

 

<0.3V

 

High level

 

1V~10V

 

Level rise/fall time

 

≤20ns

External measurement function
 

 

 

 

Frequency meter function

 

Frequency measurement range

 

 

1Hz~100MHz

 

Measurement accuracy

 

Gate time 0.01S~10s continuous adjustment

 

 

 

Counter function

 

Counting range

 

0-4294967295

 

Coupling method

 

DC and AC coupling methods

   

Counting method

 

Manually

 

Input signal voltage range

 

2Vpp~20Vpp

 

Pulse width measurement

 

0.01us resolution, maximum measurable 20s

 

Period measurement

 

0.01us resolution, maximum measurable 20s

Sweep function
 

Sweep channel

 

CH1 or CH2

 

Sweep type

 

Linear sweep, logarithmic sweep

 

Sweep time

 

0.1s~999.9s

 

 

Setting range

 

Any setting between the maximum output frequency of the corresponding model of the starting point (0.01Hz) and the end point

 

Sweep direction

 

Forward, reverse and round trip

Bursting function
 

Number of pulses

 

1-1048575

 

 

Burst mode

 

Manual burst, CH2 burst, external burst (AC), external burst (DC)

General specifications
 

Display

 

Display type

 

2.4 inch TFT color LCD display

 

 

 

Store and load

 

Quantity

 

100

 

Position

 

00 to 99 (00 memory location parameter is loaded by default as power on)

 

Arbitrary wave

 

Quantity

 

1 to 60 total 60 groups (15 groups by default as power on)

 

 

 

 

 

 

 

 

Interface

 

Interface mode

 

USB to serial interface

 

Extension interface

 

With TTL level mode serial interface for user secondary development

 

Communicat ion speed

 

 

Adopt standard 115200bps

 

Protocol

 

Using the command line, the protocol is made public

 

Power supply

 

Voltage range

 

DC5V±0.5V

 

Manufacturing technology

 

Surface mount technology, large-scale integrated circuits, high reliability, long service life

 

Prompt tone

 

Users can turn on or off by setting program

 

Operating characteristics

 

All key operations, knob continuous adjustment

 

Environmental conditions

 

Temperature: 0~40 oC Humidity: <80%

Instrument Description

The front panel overviewJUNTEK-JDS2900 Series-Dual-Channe-Function-Arbitrary-DDS-Signal-Generator -

The display interface descriptionJUNTEK-JDS2900 Series-Dual-Channe-Function-Arbitrary-DDS-Signal-Generator -2

  1. CH1 pa,~ler
  2. CH2 par-ter
  3. Wavefor■ Display
  4. Cunent Channel Output Stalus
  5. Soft – key •mu bar
  6. The phase d iffe.rence between CH1 a.nd Cff2

The key function description

 

Item

 

Instructions

 

Function soft keys

 

Function soft-key activates the corresponding function on the screen

(wA  

Press(w  A     button to display main interface or waveform selection and cancel

 

(MEAS]

 

Fast switching between measurement mode interface and main interface

   

Fast switching between modulation mode interface and main interface

§]  

Fast switching between system setting interface and main interface

 

(OK ]

 

 

The main interface is used to control the simultaneous output of channel 1

and channel 2, and in other interface,  [   OK]   key is used to control (ON/OFF).

mw  

When setting parameters, you can use left and right keys to move the cursor position.

 

( CHl )

 

Select the CH1 channel to control the output of CH1, long press to set CH1 as the main display.

 

( CH2)

 

Select the CH2 channel to control the output of CH2, long press to set CH2 as the main display.

Operation Instructions

After power on, first enter the welcome interface and then jump to the language selection interface. Press the corresponding soft key to select the language and finally enter the main interface. After you turn on the computer again, you do not need to repeat the language selection and go directly to the main interface.JUNTEK-JDS2900 Series-Dual-Channe-Function-Arbitrary-DDS-Signal-Generator -3

Set the parameters in the main interface and output waveform

  • Press button to turn the output on or off simultaneously for both channels.
  • Output channel selection: The front panel , keys are used to switch the currently selected channel (CH1 or CH2). Pressing , keys again in the currently selected channel can turn on/off the output of the channel, and long press to place the current channel on the main display of the screen. (upper part).
  • Set the waveform: press the front panel key to activate the waveform switching of the current channel. In the active state of the waveform, the knob can be quickly switched, and the direction key can be used to quickly switch between the arbitrary waveform and the preset waveform.
  • Set Frequency: Press the soft key to highlight the “Frequency” parameter. At this time, use the direction keys to move the cursor to select the bit to be edited. Then turn the knob to change the value. Press and hold the soft key to change the frequency unit (MHz, KHz, Hz, mHz). , uHz).
  • Press and hold the duty cycle, offset, and phase soft-keys to initialize to default values.

MEAS measurement mode interface parameter settings
Press and press the soft key in the measurement mode interface to switch between the measurement function and the count function. You can also rotate the encoder to switch.

Measurement function
The input signal frequency, period, positive pulse width, negative pulse width, duty cycle and other parameters can be measured, the measurement frequency range 1Hz-100MHz, the measurement signal amplitude range is 2mVpp-20Vpp, the input interface is Ex

  • Coupling setting: Press to switch the coupling mode to AC or DC.
  • Gate time setting: Pressto set the gate time (0.01S-10S), use the arrow keys to move the cursor to select the bit to be edited, then turn the knob to adjust the value.
  • Measurement mode setting: Press to switch between the two options of counting frequency and counting period via the encoder.
  • Measurement parameters: frequency, period, positive pulse width, negative pulse width, duty cycle.

Counting function

The period number of the input signal can be calculated in real time

  • Coupling setting: Press to switch the coupling mode to AC or DC.
  • After setting all the items, press the soft key to start the counting function

MOD modulation mode interface parameter settings

  • Press to enter the modulation mode, press the soft key in the modulation mode interface to switch between the sweep function (CH1 channel / CH2 channel), pulse function (CH1 channel) and burst function (CH1 channel).

Sweep function
Sweep frequency, you can set any starting point frequency and end point frequency in the signal generator output frequency range, sweep time 0.1s~999.9s, sweep type is linear scan, logarithm scan two scan methods, sweep frequency direction is positive , Reverse and Round Trip Three Sweep Directions;

  • In the sweep function (CH1 channel), press the soft key to select the starting point frequency, end point frequency, sweep time, sweep direction and sweep mode. After the item is highlighted, use the arrow keys (or press the soft
    • key ) and the knob to edit the item’s parameters.
  • After setting all the items, press the soft key press the key to start the sweep function and to stop.

pulse function
You can adjust pulse wave pulse width and pulse period time digitally, which is more accurate than adjusting the duty cycle;

  • In the pulse function (CH1 channel), press the soft key to select the pulse width, period, offset, and amplitude. After this item is highlighted, edit the item parameters by pressing the arrow keys (or press the soft key ) and rotating the knob. , pulse width and period units can be switched between ns and us by pressing the key when the item is highlighted.
  • After setting all the items, press the soft key to start the sweep function and press the key to stop

Bursting function
The pulse train can be set to output 1-108575 periods. The burst mode is divided into internal CH2 channel bursts, external input signal bursts, and manual bursts. It should be noted that the period time of the burst train is less than the burst signal period time.

  • In the burst function (CH1 channel), press the soft key to select the number of pulses and the burst mode. After this item is highlighted, use the arrow keys (or press the soft key ) and the knob to edit the item parameters.
  • After setting all the items, press the soft key to start the sweep function and press the key to stop.

System settings and interface parameter settings
Press the key to enter the system setting interface. Press the soft key to select the parameters for the in/out position, sound setting, brightness adjustment, language setting, synchronization function setting, and arbitrary wave display quantity setting.

  • Call Out & Save: Save/recall the current waveform parameters to the specified position, rotate the knob to adjust to the specified position. Press the corresponding soft key when you want to recall, save, or clear.
  • Sound settings: Sounds can be turned on and off with keys 、.
  • Brightness adjustment: Brightness adjustable from 0 to 12 levels can be quickly adjusted by rotating encoder.
  •  Language setting: Available by pressing 、to select English and Chinese display.
  •  Synchronization: The CH1 channel is used as the operation target during synchronization. The parameters of the CH2 channel change following the CH1 channel parameters. When the synchronization item is highlighted, press the key or rotate knob to select the item to be synchronized (frequency, waveform, amplitude, duty cycle, offset), press the soft key to select it, and press the soft key to cancel.
  • Arbitrary waveform number setting: The number of arbitrary waveforms of the main interface waveform can be quickly adjusted by rotating the encoder (1-60).

Documents / Resources

JUNTEK JDS2900 Series Dual-Channel Function Arbitrary DDS Signal Generator [pdf] User Guide
JDS2900, Series Dual-Channel Function Arbitrary DDS Signal Generator

References

Leave a comment