JONARD TOOLS logoSPARC Fire Core and SPARC Fire Clad Machines
Quick Start GuideQuick Start Guide

Key Pad Overview

JONARD TOOLS SPARC Fusion Splicer - Key Pad OverviewCalibrationJONARD TOOLS SPARC Fusion Splicer - CalibrationCalibration should be done daily. With machine on the WorkBench screen (which is initial startup screen), hit the back buttonJONARD TOOLS SPARC Fusion Splicer - icon.
Navigate to the Maintenance Menu.JONARD TOOLS SPARC Fusion Splicer - icon 1 Click the Maintenance option. JONARD TOOLS SPARC Fusion Splicer - icon 2Press “OK” to begin the calibration steps.
Hit Set to begin each step
NOTE: Steps 3-6 require that prepared fiber is set in both holders.
Steps 1 and 2 will operate with or without fiber.
Startup
Upon power up, the initial screen will be the WorkBench.JONARD TOOLS SPARC Fusion Splicer - WorkBenchThe default settings are Splice Mode: SM_ AUTO and HEATER
MODE: 60mm.
If you need to change these settings hit the RETURN key JONARD TOOLS SPARC Fusion Splicer - icon to return to the main menu and click the Splice Mode icon JONARD TOOLS SPARC Fusion Splicer - icon 3 (we recommend SM_AUTO or MM_AUTO), and adjust settings as needed. To change Heater Mode for different sized protection sleeves, click the Heater Mode icon JONARD TOOLS SPARC Fusion Splicer - icon 4 and choose the setting that best matches the size of your protection sleeve.

Fiber Preparation

JONARD TOOLS SPARC Fusion Splicer - Fiber PreparationFiber Stripper Hole ChartJONARD TOOLS SPARC Fusion Splicer - Hole Chart

JONARD TOOLS SPARC Fusion Splicer - Fiber Preparation 1
STEP 1
Carefully slip on protective sleeve
and slide down for later use.
STEP 2
Strip outer jacket using Hole 1on JIC-375.
STEP 3
Cut Aramid Yarn using JIC-186.
JONARD TOOLS SPARC Fusion Splicer - Strip buffer
STEP 4
Strip buffer using Hole 2 on JIC-375.
STEP 5
Carefully remove coating using Hole 3 on JIC-375.
JONARD TOOLS SPARC Fusion Splicer - correct channel
STEP 6
Clean the fiber using included fiber wipes (FW series).
STEP 7
Place fiber in the correct channel for your fiber size, exposed fiber end should be in the automatic trash can,
close lid to cleave. (Check manual for more information)

JONARD TOOLS SPARC Fusion Splicer - qr codehttps://uqr.to/1y0pp

Splicing Operation

Splicing steps while AUTO SPLICING is enabled

JONARD TOOLS SPARC Fusion Splicer - AUTO SPLICING
STEP 1
Open the Fusion Chamber and
fiber holders.
STEP 2
Seat fiber in holder, in V-groove,
as close to the electrodes
without touching.
STEP 3
Gently close the fiber holder.
Repeat process for second fiber.
JONARD TOOLS SPARC Fusion Splicer - Gently close
STEP 4
Gently close the Fusion Chamber cover. Splicing happens automatically.
STEP 5
Slide the sleeve over the splice and place it in the heater.
STEP 6
Press the heat button. The red light will turn on with a beep, and once complete, it will turn off with a second beep.

Spliced Fiber ResultJONARD TOOLS SPARC Fusion Splicer - Fiber ResultOnce completed remove fiber and set aside to cool.
NOTE: When splicing splice on connectors, make sure to swap the included fiber holders. Check manual for more details.JONARD TOOLS SPARC Fusion Splicer - Heat ChamberHeat Chamber Connector Fiber HolderJONARD TOOLS SPARC Fusion Splicer - Fusion ChamberFusion Chamber Connector Fiber Holder
Cleaning
For routine maintenance, use the Jonard Tools® CWP-125 Pointed Cleaning Swabs to effectively remove debris. For significant contamination, pair them with the Jonard Tools® FCF-3 Fiber Cleaning Fluid. Avoid using water; always use 99% or higher isopropyl alcohol to ensure compliance with industry standards and prevent damage. Regular maintenance is recommended before every use to keep SPARC Fusion Splicers operating as designed.

JONARD TOOLS SPARC Fusion Splicer - Cleaning
STEP 1
Use Pointed Cleaning Swabs to gently remove all scrap fiber from the V-grooves.
STEP 2
Carefully clean the lens located under the rear electrode positioned between the Fusion Chamber and the Heat Chamber.
STEP 3
Wipe the Fiber Stabilizers located under the Fusion Chamber Cover.

JONARD TOOLS SPARC Fusion Splicer - LED lightsSTEP 4
Ensure the LED lights under the Fusion Chamber Cover are free from debris.
Warning: Do not touch any of the components (V-grooves, lens, fiber stabilizers or LED lights) with your fingers. Oil and residue from your fingers can damage the machine and affect its performance. Always use appropriate cleaning tools to avoid contamination.

JONARD TOOLS SPARC Fusion Splicer - qr code 1https://uqr.to/1y627

Support Notice
Support is available only for registered SPARC Fusion Splicers. Register by scanning the QR code to ensure eligibility for assistance, warranty, and repairs.
Email FusionSupport@jonard.com
Battery Pack and Power IndicatorsJONARD TOOLS SPARC Fusion Splicer - Battery PackThe SPARC™ Fusion Splicer supports uninterrupted operation.
It can be used while plugged in, allowing the battery to charge during use. With two batteries, you can charge one externally while working with the other, ensuring uninterrupted splicing.JONARD TOOLS logo

Documents / Resources

JONARD TOOLS SPARC Fusion Splicer [pdf] User Guide
SPARC Fire Core, SPARC Fire Clad, SPARC Fusion Splicer, SPARC, Fusion Splicer, Splicer

References

Leave a comment

Your email address will not be published. Required fields are marked *