JBC LOGO

JBC WSU-9A Wire Stripper Control Unit

JBC WJBC WSU-9A Wire Stripper Control UnitSU-9A Wire Stripper Control Unit

Packing ListJBC WSU-9A Wire Stripper Control Unit 1

Features

JBC WSU-9A Wire Stripper Control Unit 2

CONNECTION

Connection with WS140

JBC WSU-9A Wire Stripper Control Unit 3

Connection with WS440JBC WSU-9A Wire Stripper Control Unit 4

Control ProcessJBC WSU-9A Wire Stripper Control Unit 5

Work Mode

WSS offers two different working modes. Switch the power on choose between Material Mode and Custom Mode by pressing the button

  •  Material ModeJBC WSU-9A Wire Stripper Control Unit 6
    • Choose between the different materials by pressing the buttons and to choose between all different material options.JBC WSU-9A Wire Stripper Control Unit 7
  •  Custom ModeJBC WSU-9A Wire Stripper Control Unit 8
    • To work on a customized mode, press and then the buttons and to select the power levelJBC WSU-9A Wire Stripper Control Unit 9

Operation

Depending on where the tool is located, the soldering station switches between three different states: Work, Sleep and Hibernation. These states are available for JBCs wire strippers WS140 and WS440.

  •  WorkJBC WSU-9A Wire Stripper Control Unit 10
    • When the wire stripper is lifted from the stand, the cartridges will heat up according to the selected configuration.JBC WSU-9A Wire Stripper Control Unit 13
  •  SleepJBC WSU-9A Wire Stripper Control Unit 11
    • When the wire stripper is in the stand, the power falls after a specified time.JBC WSU-9A Wire Stripper Control Unit 14
  •  HibernationJBC WSU-9A Wire Stripper Control Unit 12
    • After longer periods of inactivity, the power is cut off and the cartridges cool down to room temperature.JBC WSU-9A Wire Stripper Control Unit 15

Troubleshooting

Station troubleshooting is available on the product page at www.jbctools.com

Material Mode

WSU incorporates predetermined power levels and it also features a customized work mode. It allows you to work on wire insulations made of thermoplastics and thermostable materials such as Teflon1, Kapton2, silicone, rubber, etc.

 

Insulation Material

 

Symbol

 

Power Level

 

Thermoplastics

Polyvinyl Chloride PVC 6%
Polyethylene PE 7%
Nylon ¹ PA 10%
Kynar ² PVDF 16%
Tefzel ¹ ETFE 17%
 

Thermostable

 

 

Teflon ¹

FEP 16%
PFA 21%
PTFE 40%
Ethylene Propylene Rubber  

EPM/EPR

 

44%

Silicone Rubber SI 51%
Kapton ¹ PI 90%

Options included:

Accessories

Pedal P305
It can be used to activate/deactivate the Wire Stipper. Sleep and hibernation delay has to be set to 0 min. Lift the wire stripper from the stand, press and hold the pedal to activate them and strip the wire. Once the pedal is relaesed the wire stripper enters in Hibernation. To reverse the pedal functionality flip the switch of the connection box.JBC WSU-9A Wire Stripper Control Unit 16

Flat Screw Driver
To open or fi x the wire stripper srews use JBC Flat Screw Driver Ref. 0023511.JBC WSU-9A Wire Stripper Control Unit 17
Cartridge Extractor Pliers
To manipulate the cartridges use JBC Cartridge Extractor Pliers Ref. PLR195. More Information at www.jbctools.comJBC WSU-9A Wire Stripper Control Unit 18

RemovingJBC WSU-9A Wire Stripper Control Unit 19
Inserting and PositioningJBC WSU-9A Wire Stripper Control Unit 20 

Metal Brush

For cleaning the tips if unwanted material is stuck there. Metal Brush Ref. 0022793.JBC WSU-9A Wire Stripper Control Unit 21

Maintenance

  • Before carrying out maintenance or storage, always allow the equipment to cool and unplug the stand from the station and the tool.
  •  Clean the station screen with a glass cleaner or a damp cloth.
  •  Use a damp cloth to clean the casing, the stand and the tool. Alcohol can only be used for cleaning the metal parts.
  •  Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status.
  • JBC WSU-9A Wire Stripper Control Unit 22JBC WSU-9A Wire Stripper Control Unit 22 Maintain tip surface clean in order to ensure a correct stripped wire.
  •  Periodically check all cables.
  •  Replace a blown fuse as follows (see specification chart)
  • take out the fuse holder and remove the fuse. If necessary use a tool to lever it out.JBC WSU-9A Wire Stripper Control Unit 23
  • Press the new fuse into the fuse holder and reinsert it in the station.JBC WSU-9A Wire Stripper Control Unit 24
  •  Replace any defective or damaged pieces. Use original JBC spare parts only.
  •  Repairs should only be performed by a JBC authorized technical service.

SAFTEY

Warning

  •  Do not touch the blade or the metal parts around.
  •  Do not allow the blade be close to flammable materials.
  •  Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
  •  This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved.
  •  Maintenance must not be carried out by children unless supervised.
  •  Place the tool on the stand when is not in use.
  •  Turn off the power when not in use, changing parts or storing.

Caution

  •  Do not use the Wire Stripper for other applications than wire stripping.
  •  Do not modify or customize the Wire Stripper.
  •  Do not hit the blade against workbench to eliminate stripped insulation debris. This behavior would damage the blade.
  •  Remove power from the tool by holding the plug, not the wires.
  •  Be careful with the fumes produced when stripping. We recomend to use our fume extractor

SpecificationsJBC WSU-9A Wire Stripper Control Unit 25

Documents / Resources

JBC WSU-9A Wire Stripper Control Unit [pdf] Instruction Manual
WSU, WSU-9A, WSU-1A, WSU-2A, Wire Stripper Control Unit, WSU-9A Wire Stripper Control Unit

References

Leave a comment

Your email address will not be published. Required fields are marked *