1. はじめに
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Nordyne 624626 OEM Replacement Furnace Control Board. Please read this manual thoroughly before proceeding with any installation or service to ensure proper function and safety.
2. 安全情報
警告:不適切な設置、調整、改造、サービス、またはメンテナンスは、物的損害、人身傷害、または死亡につながる可能性があります。設置およびサービスは、資格のある設置業者、サービス代理店、またはガス供給業者によって実施される必要があります。
- Always disconnect electrical power to the furnace before installing or servicing the control board. Failure to do so can result in electrical shock, personal injury, or death.
- Ensure all wiring connections are secure and conform to local and national electrical codes.
- Handle the control board by its edges to avoid damaging electronic components due to static discharge.
- Verify that the replacement board is the correct model for your furnace to prevent operational issues or damage.
3.製品オーバーview
The Nordyne 624626 OEM Replacement Furnace Control Board is a critical component designed to manage the operational sequences of your furnace. It ensures proper ignition, flame sensing, blower operation, and safety shutdowns.

Figure 1: Nordyne 624626 OEM Replacement Furnace Control Board. This image displays the circuit board with various electronic components and connectors, typical for a furnace control unit.
主な特徴:
- Genuine OEM replacement part, ensuring compatibility and reliability.
- Manages furnace ignition, flame sensing, and blower motor operation.
- Integrates safety features to prevent hazardous conditions.
4. インストール
This section outlines the general steps for replacing a furnace control board. Due to the complexity and safety risks involved, it is highly recommended that installation be performed by a qualified HVAC technician.
- 電源切断: Locate the main electrical disconnect for the furnace and turn off the power. Additionally, turn off the gas supply to the furnace. Verify power is off using a voltageテスター。
- コントロールボードにアクセスします。 炉のアクセス パネルを開いて、既存の制御ボードを見つけます。
- ドキュメント配線: Before disconnecting any wires, take clear photographs or make detailed diagrams of all wiring connections to the old control board. This is crucial for correct re-connection.
- ワイヤーを外す: Carefully disconnect all wires and connectors from the old control board. Note any specific routing or bundling.
- 古いボードを削除します。 Unmount the old control board from its housing. It may be secured with screws, clips, or standoffs.
- 新しいボードをインストールします: Mount the Nordyne 624626 replacement board in the same location and orientation as the old board. Ensure it is securely fastened.
- 配線を再接続します: Using your photographs or diagrams, carefully reconnect all wires and connectors to the new control board. Double-check each connection for accuracy and security.
- アクセス パネルを閉じる: すべての接続を確認したら、炉のアクセス パネルを閉じて固定します。
- 電力とガスの復旧: Turn on the gas supply and then restore electrical power to the furnace.
- テスト操作: Initiate a heating cycle to ensure the furnace operates correctly and the new control board is functioning as expected. Observe for any error codes or unusual behavior.
5. 操作手順
The Nordyne 624626 control board operates automatically as part of your furnace system. User interaction is primarily through the thermostat, which sends signals to the control board to initiate heating or cooling cycles.
- Ensure your thermostat is set to the desired mode (Heat/Cool) and temperature.
- The control board will manage the sequence of operations, including igniting the burner, monitoring flame, and controlling the blower fan.
- Refer to your furnace's main user manual for specific operational details and thermostat settings.
6. メンテナンス
The control board itself requires minimal maintenance. However, regular inspection of the furnace system is recommended to ensure its longevity and proper function.
- 年次検査: Have a qualified HVAC technician perform an annual inspection of your furnace, including the control board and its connections.
- 目視検査: Periodically, with power disconnected, visually inspect the control board for any signs of overheating, burnt components, or loose connections.
- 清潔さ: Ensure the area around the control board is free from dust and debris, which can impede airflow and lead to overheating.
7。 トラブルシューティング
If your furnace is not operating correctly after installing the new control board, consider the following common troubleshooting steps. Always disconnect power before inspecting internal components.
| 問題 | 考えられる原因 | 解決 |
|---|---|---|
| 炉が始動しない | No power to furnace; thermostat issue; incorrect wiring; safety lockout. | Check circuit breaker; verify thermostat settings; re-check all wiring connections; reset furnace by cycling power. |
| ブロワーが動作していません | Blower motor issue; wiring error; control board fault. | Ensure blower fan is not obstructed; verify blower motor wiring; consult a technician if board fault is suspected. |
| 点火なし | Gas supply off; igniter fault; flame sensor dirty; wiring issue. | Check gas valve; inspect igniter for damage; clean flame sensor; verify wiring to igniter and sensor. |
| 表示されるエラーコード | 特定のシステム障害。 | Refer to your furnace's main manual for error code definitions and troubleshooting steps. |
If issues persist after basic troubleshooting, it is recommended to contact a qualified HVAC technician for diagnosis and repair.
8. 仕様
- モデル: Nordyne 624626
- タイプ: OEM交換用炉制御ボード
- メーカー: ノルダイン
- 製品寸法: 6 x 6 x 6インチ
- 商品の重量: 11オンス
- 材料: プラスチック
- 表示タイプ: LCD or LED (if applicable, for status indicators)
- 動作温度: 40 Degrees Fahrenheit (minimum, typical for indoor furnace environment)
- ASIN: B00FPUSF9S
9. 保証情報
Warranty coverage for the Nordyne 624626 OEM Replacement Furnace Control Board is typically provided by the manufacturer or the seller at the time of purchase. Please retain your proof of purchase and refer to the warranty documentation included with your original product or contact the seller/manufacturer directly for specific warranty terms and conditions.
10. カスタマーサポート
For technical assistance, installation questions, or warranty claims, please contact the original seller or Nordyne customer support. Have your product model number (624626) and proof of purchase ready when contacting support.
Nordyne Contact Information: Please refer to the official Nordyne website or your furnace documentation for the most current contact details.