FP4151TN-V2 QUICK START GUIDE

Product Code: FP4151TN-V2: 15", 1024 x 768, XGA Color TFT with 4-wire analog resistive touch screen with 2 communication ports, one USB Device port, one USB Host port & 1 Ethernet Port.

GETTING STARTED

User should follow the given sequence to configure and use any FlexiPanels series unit:

  1. Install FlexiSoft Software.
  2. Create a PZM application using FlexiSoft software.
  3. Connect programming cable.
  4. Download Firmware i.e. driver for the HMI.
  5. Download application.
  6. Now FP unit is ready to use in the system.

For more information, visit www.renuelectronics.com

SPECIFICATIONS

Parameter Details
Power (Base) 24VDC (+20%), 600mA, 14.4W
Display 15", 1024 x 768pixels, XGA color TFT with 4-wire analog resistive touch screen
LEDs 1
RAM Memory 512MB
User Application Up to 1GB that includes user application, data log, alarms, retentive memory and logic memory
eMMC 4GB
RTC Built-in, date and time function
Weight Approx. 3Kg
Product Dimensions 402.3(W) x 287.0(H) x 67.5(D)mm
Panel Cut-out 388.0(W) x 287.0(H)mm
LCD Backlight life: Module Typical 70,000 h
LED life time: Minimum 50,000h
Luminance: Minimum 320 cd/m2 (Typical 400 cd/m2)
Communication
COM1 and COM2 RS232/RS485
USB Ports 1 USB Type C Port and 1 USB Host Port
Ethernet 1 Ethernet Port
Default IP Address & Subnet Mask: Auto
SD Card Micro SD [High Capacity (4GB to 32GB)]
Speed Class: @@@@
[While inserting and removing SD card, please make sure to TURNOFF the power to the unit.]
Environment & Approvals
Operating Temperature 0° to 60°C*
Storage Temperature -30° to 85°C
Humidity 10 to 90% (Non-Condensing)
Shock IEC 60068-2-27
25g, 11ms, 6 shocks per axis, total 18 shocks (X, Y, Z)
Vibration IEC 60068-2-6
5 to 150Hz, 3g peak (X, Y, Z)
EMC EN 55011: 2009/A1: 2010
EN 61131-2:2007
EN 61000-6-2: 2005/AC: 2005
EN 61000-6-4: 2007/A1: 2011
Protection Front panel-IP66, Rear panel-IP20
APPROVALS CE, UL(Class1 Div2), UKCA, REACH & ROHS
[*Note: For UL, operating temperature range is 0° to 50°C.]

PRODUCT DIMENSIONS

A diagram showing the front, right side, top, and bottom views of the FP4151TN-V2 unit with dimensions labeled.

Front View: 402.3(W) x 287.0(H) x 67.5(D)mm

Right Side View: 67.5mm depth

Top View: 402.3(W) x 301.3(H)mm

Bottom View: 402.3(W) x 301.3(H)mm

WARNINGS

COMMUNICATION INTERFACES

This section provides information regarding communication interfaces supported by this product.

COM1 & COM2: RS485/RS232

A diagram showing the pinout for RS232 and RS485 connections.

RS232 Pinout:

Pin number Signal
2 TXD(RS232)
3 RXD(RS232)
5 GND

RS485 Pinout:

Pin number Signal
2 TX+(RS422/RS485)
3 RX+(RS422/RS485)
7 NC
8 TX-(RS422/RS485)
9 RX-(RS422/RS485)

Ethernet Port

  1. Fully compliant with IEEE 802.3 / 802.3u standards.
  2. 10/100 Mbps support.
  3. Connector used: Standard shielded RJ-45 female jack with in-built speed and link activity indication LEDs.

USB Device Port

  1. USB Device port, compliant with USB2.0 specification, self-powered device.
  2. Connector used: Micro USB Type C Female connector.

USB Host Port

  1. USB Host, compliant with USB 2.0 specification.
  2. USB Host can be used to transfer logged data and historical alarm to USB memory stick.
  3. USB Host can handle only USB memory stick devices and can source current up to 150mA only.
  4. Connector used: Standard USB Type a Female connector.

Cable Diagrams

Diagrams illustrating PC to unit programming cable (RS232) and 2-wire and 4-wire RS485 connections.

Earthing

The optimum method for Earthing electronic equipment is to earth it separately from other high-power systems, to earth more than one unit of electronic equipment with a single-point earth. The Earthing marked terminal (see below) is provided on the unit.

A diagram shows DC+, DC-, and Earth terminals for 24Vdc power input.

[Note: Do not use an earth that has an unstable impedance, such as painted screws or earth subject to vibration.]

UL APPROVAL

Information regarding UL approval for hazardous and non-hazardous locations, including Class I Division 2 Groups A B C and D. Details on associated apparatus, capacitance, and inductance values are provided.

REVISION HISTORY

Rev. Description Date
1.2 Specification updated 09/06/2025
1.1 Control cable details removed, RENU logo updated 06/06/2022
1.0 First Draft 21/10/2021

RENU Electronics Pvt. Ltd. reserves the right to change or discontinue specifications and features without prior notice. To view the latest and updated datasheets/manuals please visit www.renuelectronics.com.

Models: FP4151TN-V2 HMI Touch Panel, FP4151TN-V2, HMI Touch Panel, Touch Panel, Panel

File Info : application/pdf, 2 Pages, 1.03MB

PDF preview unavailable. Download the PDF instead.

fp4151tn-v2-r11

References

Microsoft Word 2010 Microsoft Word 2010

Related Documents

Preview RENU FlexiPanels FP4 Advanced HMI Series Datasheet
Datasheet for RENU FlexiPanels FP4 Advanced HMI series, detailing features, specifications, application examples, supported protocols, ordering information, and dimensions for models FP4043CN, FP4070CN, and FP4101CN.
Preview FlexiPanels FP2 V2 Basic HMI Series: Technical Specifications and Features
Explore the FlexiPanels FP2 V2 Basic HMI series, featuring a 4.3" color TFT display, robust connectivity options including RS232, RS485, USB, and Ethernet, and compliance with CE, UL Class I Div 2, RoHS, and IP66 standards. This document details model specifications, supported protocols, and application examples.
Preview FlexiPanels FP2 V2 Basic HMI Series Datasheet
Datasheet for the RENU FlexiPanels FP2 V2 Basic HMI series, featuring a 4.3" color TFT display, RS232/RS485 communication, and industrial approvals.
Preview FlexiPanels FP2 V2 Basic HMI Series Datasheet
Datasheet for the RENU FlexiPanels FP2 V2 Basic HMI series, featuring a 7" Color TFT display, analog resistive touch screen, and various communication options.
Preview Renu FlexiPanels FP2 V2 Basic HMI Series Datasheet
Datasheet for the Renu FlexiPanels FP2 V2 Basic HMI series, featuring a 7" TFT display, analog resistive touch screen, and various communication and environmental specifications.
Preview RENU FP4101 Series: Industrial Touch Panel Quick Start Guide
This guide introduces the RENU FP4101 Series industrial touch panels, detailing models like FP4101T and FP4101TN. It covers key specifications, connectivity options (USB Type C, Ethernet, RS232/RS485), getting started steps, and industrial certifications such as UL Class I Division 2.
Preview FP2070TN-LE2016RP-A0402U FlexiPanels FP2 HMI Datasheet
Detailed specifications and features of the RENU FlexiPanels FP2 FP2070TN-LE2016RP-A0402U, a 7-inch color TFT HMI with local and pluggable I/Os, offering advanced controller functions and robust connectivity.
Preview WP6101TN Plus Quick Start Guide
A quick start guide for the WP6101TN Plus Thin Client, detailing its specifications, product dimensions, panel cutout dimensions, communication interfaces, getting started steps, main settings, UL approval, and revision history.