its-LOGO

its TEQ Diffused Flexible Light

its-TEQ-Diffused-Flexible-Light-PRODUCT

Specifications

  • Part Numbers: TEQ, TBQ, TPB, TPC, TPD, TPE, TPQ, TSB, TSQ, RBLL, RELL, RHLL & RSLL
  • Power Supply: UL Recognized (purchased separately)
  • Mounting Channel: Purchased separately

FAQs

  • Q: Can I field-cut the flexible light?
    • A: No, field-cutting the light will void the warranty.
  • Q: What should I use to clean the surface before installation?
    • A: Clean the surface with a mixture of 50% water/50% isopropyl alcohol and let it dry.
  • Q: Can I install the flexible light on rough plywood or edges?
    • A: It is recommended to use mounting channels TPB-1 or TPB-2 instead of installing on rough surfaces.

PARTS TOOLS NEEDED

Part#: TEQ, TBQ, TPB, TPC, TPD, TPE, TPQ, TSB, TSQ, RBLL, RELL, RHLL & RSLL

its-TEQ-Diffused-Flexible-Light-FIG-1 (1)

IMPORTANT SAFETY INSTRUCTIONS

  • IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY FOR YOUR PROTECTION AND SAVE ALL INSTRUCTIONS.
  • Disconnect power before installing, adding, or changing any component.
  • To avoid a hazard to children, account for all parts and destroy all packing materials.
  • Use only with a UL-approved power supply.
  • The addressable flex light is NOT polarity protected. Wiring the light incorrectly could cause damage.

INSTALLATION CONSIDERATIONS

  • It is recommended that fuse protection be added to the positive (+) input.
  • Do not bend lighting more than necessary. It should only be bent to a 1” radius. Bending to a tight 90° angle could cause damage to the circuit.
  • Only bend the LED ribbon in one natural direction, do not try to bend it in an unnatural direction such as twisting.
  • Make sure surfaces are smooth, clean, and free of dust and debris before installing this product. Surfaces should be cleaned and primed per the 3M specified cleaning instructions* on page two. Failure to properly clean the surface may result in loss of adhesion.
  • Rough surfaces may prevent proper adhesion. If adhesion failure occurs, screw-in mounting channels may be used for installation. Contact ITC sales for more information on mounting channels: 616-396-1355 / sales@itc-us.com.

its-TEQ-Diffused-Flexible-Light-FIG-1 (2)

INSTALLATION INSTRUCTIONS

  1. Clean the surface with a mixture of 50% water/50% isopropyl alcohol. Let the surface dry.its-TEQ-Diffused-Flexible-Light-FIG-1 (3)
  2. Apply Primer 94 as recommended by 3M. Failure to follow the surface preparation guidelines will void the warranty.its-TEQ-Diffused-Flexible-Light-FIG-1 (4)
  3. Remove the paper backing and firmly press the light in place. DO NOT slide or drag your thumb along the tape light or the silicone may be pulled off.its-TEQ-Diffused-Flexible-Light-FIG-1 (5)
  4. If using mounting channels for installation, they are available in screw or adhesive mount. Install per your desired method.
    • Screw Mount Channel: Screws should be used every 12”.
    • Adhesive Mount Channel: Follow the same cleaning instructions above remove paper backing from the channel and press in place.
    • Both Channels: Remove the paper backing from the light and press the light into the channel.its-TEQ-Diffused-Flexible-Light-FIG-1 (6)
  5. Wire the light based on the wiring diagrams below.its-TEQ-Diffused-Flexible-Light-FIG-1 (7)
  6. Please review the considerations below to ensure a successful installation.
    • Flexible light cannot be field cut. Field cutting the light will void the warranty.its-TEQ-Diffused-Flexible-Light-FIG-1 (8)