Introduzione
Thank you for choosing the Rexel 19 Watt 75 Watt Equivalent Spiral CFL Light Bulb. This manual provides essential information for the safe and efficient use of your new compact fluorescent lamp (CFL). Please read these instructions carefully before installation and retain them for future reference.
This CFL bulb is designed to provide a soft white light at 3000 Kelvin, offering an energy-efficient alternative to traditional incandescent bulbs. It consumes only 19 watts while providing light output equivalent to a 75-watt incandescent bulb.
Informazioni sulla sicurezza
Always follow basic safety precautions when installing or handling electrical products. Failure to do so may result in fire, electric shock, or personal injury.
- AVVERTIMENTO: Risk of electric shock. Disconnect power before installation, inspection, or removal.
- Do not use with dimmers unless specifically rated for dimmable CFLs. This bulb is not designed for use with dimmers.
- Do not use in totally enclosed luminaires. Restricted airflow can shorten bulb life.
- Not suitable for use in emergency exit fixtures or emergency lights.
- Avoid touching the glass spiral portion of the bulb directly with bare hands. Oils from skin can reduce bulb life.
- Allow the bulb to cool before removing it.
- This bulb contains a small amount of mercury. Refer to the "Disposal" section for proper handling and recycling instructions.
- Tenere fuori dalla portata dei bambini.
Prodotto finitoview

Figura 1: Retail packaging for the Rexel 19 Watt Spiral CFL Light Bulb. The packaging highlights key features such as "Soft White," "19 Watts," "1200 Lumens," and "8000 Hours" of life.

Figura 2: The Rexel 19 Watt Spiral CFL Light Bulb. This image shows the spiral-shaped glass tube and the standard screw-in base (E26/E27 type). The base includes markings for wattage, voltage, frequency, and color temperature.
The Rexel Spiral CFL Light Bulb features a compact, spiral-shaped fluorescent tube designed for energy efficiency. It is equipped with a standard Edison screw base for easy installation into most common light fixtures.
Specifiche
| Caratteristica | Specificazione |
|---|---|
| Marca | Rexel |
| Tipo di luce | CFL (fluorescente compatta Lamp) |
| Cosatage | 19 Watt (equivalenti a 75 Watt) |
| Colore chiaro | Bianco morbido |
| Temperatura del colore | 3000 gradi Celsius |
| Conteggio unità | 1.0 Conteggio |
| Forma | Spiral (Tubular) |
| Materiale | Rame (componenti di base) |
| Peso dell'articolo | 6 once |
Configurazione e installazione
Follow these steps to safely install your Rexel CFL light bulb:
- Assicurarsi che l'alimentazione sia disattivata: Before attempting any installation, turn off the power to the light fixture at the wall switch and, if possible, at the circuit breaker.
- Allow Fixture to Cool: If replacing an old bulb, ensure the fixture and the old bulb have cooled down completely to avoid burns.
- Disimballare la lampadina: Carefully remove the new Rexel CFL bulb from its packaging. Handle the bulb by its plastic base, avoiding direct contact with the glass spiral.
- Avvitare la lampadina: Gently screw the bulb into the light fixture's socket. Turn clockwise until it is snug, but do not overtighten. Overtightening can damage the bulb or the fixture.
- Ripristina alimentazione: Once the bulb is securely installed, restore power at the circuit breaker and turn on the wall switch.
- Verifica operazione: The bulb should illuminate immediately. Note that CFLs may take a few seconds to reach full brightness, especially in colder environments.
Istruzioni per l'uso
Operating the Rexel CFL light bulb is straightforward:
- Accensione/spegnimento: Per accendere o spegnere la lampadina, utilizzare l'interruttore a parete standard collegato all'apparecchio di illuminazione.
- Tempo di riscaldamento: CFLs may require a short warm-up period (typically 30-60 seconds) to reach full brightness and stable color. This is normal and does not indicate a defect.
- Commutazione frequente: While CFLs are designed for many on/off cycles, very frequent switching (e.g., multiple times per minute) can slightly reduce their lifespan. For best results, avoid rapid, repeated switching.
Manutenzione
The Rexel CFL light bulb requires minimal maintenance:
- Pulizia: Ensure the power is off and the bulb is cool before cleaning. Gently wipe the bulb with a soft, dry, lint-free cloth. Do not use liquid cleaners or abrasive materials.
- Gestione: Always handle the bulb by its plastic base. Avoid dropping the bulb or subjecting it to strong impacts.
- Sostituzione: Replace the bulb when it reaches the end of its useful life or if it becomes damaged. Refer to the "Disposal" section for proper disposal of used CFLs.
Risoluzione dei problemi
If you encounter issues with your Rexel CFL light bulb, refer to the following common problems and solutions:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| La lampadina non si accende. | No power to the fixture, bulb not screwed in properly, or bulb has reached end of life. | Check wall switch and circuit breaker. Ensure bulb is securely screwed into the socket. If still no light, replace the bulb. |
| Bulb flickers or takes a long time to warm up. | Normal warm-up behavior for CFLs, especially in cold environments. Could also indicate an incompatible dimmer or nearing end of life. | Allow adequate warm-up time. Ensure no dimmer is being used unless the bulb is rated for it. If flickering persists or worsens, replace the bulb. |
| Bulb is buzzing. | Incompatible dimmer, loose connection, or internal component issue. | Ensure no dimmer is being used. Check that the bulb is tightly screwed in. If buzzing continues, replace the bulb. |
Disposizione
This Rexel CFL light bulb contains a small amount of mercury, which is common for fluorescent lighting. Proper disposal is crucial to protect the environment and human health.
- Do NOT dispose of CFLs in regular household trash.
- Riciclare: Many retailers, local waste management facilities, and hazardous waste collection sites offer free recycling for CFLs. Visit www.epa.gov/cfl/recycling-cfls or your local government's waste management website for recycling options in your area.
- Broken Bulb Cleanup: In case of a broken bulb, ventilate the area for 5-10 minutes. Carefully scoop up glass fragments and powder using stiff paper or cardboard. Use sticky tape to pick up remaining small pieces. Wipe the area with a damp paper towel. Place all cleanup materials in a sealed plastic bag and dispose of it according to local hazardous waste guidelines. Do NOT use a vacuum cleaner.
Informazioni sulla garanzia
Rexel products are manufactured to high-quality standards. Specific warranty terms and conditions for this product are typically provided on the product packaging or can be obtained directly from the manufacturer's official websito. Conservare la prova d'acquisto per eventuali reclami in garanzia.
Assistenza clienti
For further assistance, technical support, or inquiries regarding your Rexel 19 Watt 75 Watt Equivalent Spiral CFL Light Bulb, please refer to the contact information provided on the product packaging or visit the official Rexel website. When contacting support, please have your product model information (ASIN: B07D96JYVX) ready.





